Cited by 23Healthcare Technology and Patient MonitoringElectronic Health Records SystemsUsability and User Interface Design

Human factors approach to evaluate the user interface of physiologic monitoring

Fidler, Richard, Bond, Raymond, Finlay, Dewar, Guldenring, Daniel, Gallagher, Anthony, Pelter, Michele, Drew, Barbara, Hu, Xiao·2015·Journal of Electrocardiology

Abstract

Background As technology infiltrates more of our personal and professional lives, user expectations for intuitive design have driven many consumer products, while medical equipment continues to have high training requirements. Not much is known about the usability and user experience associated with hospital monitoring equipment. This pilot project aimed to better understand and describe the user interface interaction and user experience with physiologic monitoring technology.Design This was a prospective, descriptive, mixed-methods quality improvement project to analyze perceptions and task analyses of physiologic monitors.Methods Following a survey of practice patterns and perceived abilities to accomplish key tasks, 10 voluntary experienced physician and nurse subjects were asked to perform a series of tasks in 7 domains of monitor operations on GE Monitoring equipment in a single institution. For each task analysis, data were collected on time to complete the task, the number of button pushes or clicks required to accomplish the task, economy of motion, and observed errors.Results Although 60% of the participants reported incorporating monitoring data into patient care, 80% of participants preferred to receive monitoring data at the point of care (bedside). Average perceived central station usability is 5.3 out of 10 (ten is easiest).Conclusions High variability exists in monitoring station interaction performance among those participating in this project. Alarms were almost universally silenced without cognitive recognition of the alarm state. Education related to monitoring operations appeared largely absent in this sample. Most users perceived the interface to not be intuitive, complaining of multiple layers and steps for data retrieval. These clinicians report real-time monitoring helpful for abrupt changes in condition like arrhythmias; however, reviewing alarms is not prioritized as valuable due to frequent false alarms. Participants requested exporting monitoring data to electronic medical records. Much research is needed to develop best practices for display of real-time information, organization and filtering of meaningful data, and simplified ways to find information.

Integrity signals

Registry

Crossref · 10.1016/j.jelectrocard.2015.08.032

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Although electronic applications in health care have been implemented for more than a decade, usability-efficient, effective, and safe use of technology-is still not fully optimized for clinical use.

    “Although the implementation of electronic applications in health care dates back more than a decade, usability—referring to the efficient, effective, and safe use of technology—is still not fully optimized for clinical use [36,37].”

Cites

Flagged first, then by citations

1 of the 4 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Fidler, R., Bond, R., Finlay, D., Guldenring, D., Gallagher, A., Pelter, M., Drew, B., & Hu, X.
Affiliations
  • San Francisco VA Medical Center (US)
  • University of Ulster (GB)
  • University of California, San Francisco (US)
Corresponding author
Fidler, Richard
Venue
Journal of Electrocardiology
Publisher
Elsevier BV
Published
2015-11
Volume
48
Issue
6
Pages
982-987
ISSN
0022-0736 (ISSN-L)
OpenAlex
W2117088313
Cited by
23
References
4
Citations by year
2026: 1 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 4 · 2018: 2 · 2017: 4
FWCI
2.01
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Electrocardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
Keywords
physiological monitoring, user interface usability, user experience, task analysis, alarm management, false alarms, bedside monitoring, electronic health records, clinician training, human factors
MeSH terms
Adult, Aged, Clinical Competence, Consumer Behavior, Female, Humans, Ergonomics, Male, Man-Machine Systems, Middle Aged, Monitoring, Physiologic, Pilot Projects, United States, User-Computer Interface, Clinical Alarms

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review