The DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Machine learning in the electrocardiogram
Abstract
The electrocardiogram is the most widely used diagnostic tool that records the electrical activity of the heart and, therefore, its use for identifying markers for early diagnosis and detection is of paramount importance. In the last years, the huge increase of electronic health records containing a systematised collection of different type of digitalised medical data, together with new tools to analyse this large amount of data in an efficient way have re-emerged the field of machine learning in healthcare innovation. This review describes the most recent machine learning-based systems applied to the electrocardiogram as well as pros and cons in the use of these techniques. Machine learning, including deep learning, have shown to be powerful tools for aiding clinicians in patient screening and risk stratification tasks. However, they do not provide the physiological basis of classification outcomes. Computational modelling and simulation can help in the interpretation and understanding of key physiologically meaningful ECG biomarkers extracted from machine learning techniques.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In this regard, wearable ECG sensors continuously monitor heart activity and facilitate early detection of arrhythmias and cardiovascular abnormalities [181].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [181]
In the citing paper
“Additionally, multimodal sensing, combining ECG data with other physiological and environmental parameters, such as EOG, EMG, temperature, strain, humidity, and bacterial infection, facilitated a comprehensive health profile [8,181,237] (Figure 7c).”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [181]
In the citing paper
“Integrating AI and ML algorithms into wearable ECG sensors has substantially enhanced the accuracy of ECG analysis [181].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [181]
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
(2016) · Cited by 11,679
The UK Biobank resource with deep phenotyping and genomic data
Bycroft, C., Freeman, C., Petkova, D., Band, G., Elliott, L. T., Sharp, K., Motyer, A., Vukcevic, D., Delaneau, O., O’Connell, J., et al. (2018) · Nature · doi:10.1038/s41586-018-0579-z · Cited by 8,876
Pattern Recognition and Machine Learning
(2007) · Kybernetes · doi:10.1108/03684920710743466 · Cited by 8,545
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,834
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
Serkan Kiranyaz, B., İnce, T., & Gabbouj, M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468589 · Cited by 1,997
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martínez, J. P., Almeida, R., Olmos, S. C., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,653
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., et al. (2018) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0471-x · Cited by 773
Laguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in cardiology · doi:10.1109/cic.1997.648140 · Cited by 605
Principal Component Analysis in ECG Signal Processing
Castells, F., Laguna, P., Sörnmo, L., Bollmann, A., & Millet, J. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/74580 · Cited by 372
Convolutional Recurrent Neural Networks for Electrocardiogram Classification
Zihlmann, M., Perekrestenko, D., & Tschannen, M. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.070-060 · Cited by 269
Lyon, A., Mincholé, A., Martínez, J. P., Laguna, P., & Rodríguez, B. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0821 · Cited by 238
Self-citationLyon, A., Ariga, R., Mincholé, A., Mahmod, M., Ormondroyd, E., Laguna, P., de Freitas, N., Neubauer, S., Watkins, H. C., & Rodríguez, B. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00213 · Cited by 85
Self-citationLyon, A., Bueno‐Orovio, A., Zacur, E., Ariga, R., Grau, V., Neubauer, S., Watkins, H. C., Rodríguez, B., & Mincholé, A. (2018) · EP Europace · doi:10.1093/europace/euy226 · Cited by 48
Self-citationDeep Learning Based QRS Multilead Delineator in Electrocardiogram Signals
Camps, J., Rodríguez, B., & Mincholé, A. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.292 · Cited by 29
Self-citationZacur, E., Mincholé, A., Villard, B., Carapella, V., Ariga, R., Rodríguez, B., & Grau, V. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67552-7_8 · Cited by 18
Self-citationDiscrimination between ischemic and artifactual ST segment events in Holter recordings
Mincholé, A., Jager, F., & Laguna, P. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.09.001 · Cited by 17
Self-citationImaging for Patient-Customized Simulations and Systems for Point-of-Care Ultrasound
Pujol, S. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-67552-7 · Cited by 13
Flagged first, then by citations
1 of the 22 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 510
Deep learning and the electrocardiogram: review of the current state-of-the-art
Somani, S. S., Russak, A. J., Richter, F., Zhao, S., Vaid, A., Chaudhry, F. F., Freitas, J. K. D., Naik, N., Miotto, R., Nadkarni, G. N., et al. (2020) · EP Europace · doi:10.1093/europace/euaa377 · Cited by 276
Zhu, H., Cheng, C., Yin, H., Li, X., Zuo, P., Ding, J., Lin, F., Wang, J., Zhou, B., Li, Y., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30107-2 · Cited by 208
Industry 4.0 and Digitalisation in Healthcare
Popov, V. V., Kudryavtseva, E. V., Katiyar, N. K., Shishkin, A., Stepanov, S. I., & Goel, S. (2022) · Materials · doi:10.3390/ma15062140 · Cited by 166
Metadata
- Authors
- Mincholé, A., Camps, J., Lyon, A., & Rodríguez, B.
- Affiliations
- University of Oxford (GB)
- Maastricht University (NL)
- Corresponding author
- Mincholé, Ana
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 57
- Pages
- S61-S64
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W2968959539
- Cited by
- 147
- References
- 22
- Citations by year
- 2026: 17 · 2025: 19 · 2024: 24 · 2023: 33 · 2022: 20 · 2021: 17 · 2020: 15 · 2019: 2
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Electrocardiology (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion)
- Research Publications (Maastricht University) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council
- Horizon 2020 Framework Programme
- Wellcome Trust
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- electrocardiogram, machine learning, deep learning, ECG biomarkers, risk stratification, patient screening, early diagnosis, electronic health records, computational modelling, clinical decision support
- MeSH terms
- Machine Learning, Computer Simulation, Electrocardiography, Humans, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review