Artificial intelligence for detecting mitral regurgitation using electrocardiography
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND Screening and early diagnosis of mitral regurgitation (MR) are crucial for preventing irreversible progression of MR. In this study, we developed and validated an artificial intelligence (AI) algorithm for detecting MR using electrocardiography (ECG). METHODS This retrospective cohort study included data from two hospital. An AI algorithm was trained using 56,670 ECGs from 24,202 patients. Internal validation of the algorithm was performed with 3174 ECGs of 3174 patients from one hospital, while external validation was performed with 10,865 ECGs of 10,865 patients from another hospital. The endpoint was the diagnosis of significant MR, moderate to severe, confirmed by echocardiography. We used 500 Hz ECG raw data as predictive variables. Additionally, we showed regions of ECG that have the most significant impact on the decision-making of the AI algorithm using a sensitivity map. RESULTS During the internal and external validation, the area under the receiver operating characteristic curve of the AI algorithm using a 12-lead ECG for detecting MR was 0.816 and 0.877, respectively, while that using a single-lead ECG was 0.758 and 0.850, respectively. In the 3157 non-MR individuals, those patients that the AI defined as high risk had a significantly higher chance of development of MR than the low risk group (13.9% vs. 2.6%, p < 0.001) during the follow-up period. The sensitivity map showed the AI algorithm focused on the P-wave and T-wave for MR patients and QRS complex for non-MR patients. CONCLUSIONS The proposed AI algorithm demonstrated promising results for MR detecting using 12-lead and single-lead ECGs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Benjamin, E. J., Muntner, P., Alonso, A., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Chang, A. R., Cheng, S., Das, S. R., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000659 · Cited by 9,036
Burden of valvular heart diseases: a population-based study
Nkomo, V. T., Gardin, J. M., Skelton, T. N., Gottdiener, J. S., Scott, C. G., & Enriquez-Sarano, M. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69208-8 · Cited by 4,881
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Interpretable Explanations of Black Boxes by Meaningful Perturbation
Fong, R. C., & Vedaldi, A. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.371 · Cited by 1,097
Ozenne, B., Subtil, F., & Maucort-Boulch, D. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2015.02.010 · Cited by 379
Cited by
Application of artificial intelligence to the electrocardiogram
Attia, Z. I., Harmon, D. M., Behr, E. R., & Friedman, P. A. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab649 · Cited by 312
Deep Learning Electrocardiographic Analysis for Detection of Left-Sided Valvular Heart Disease
Elias, P., Poterucha, T. J., Rajaram, V., Moller, L. M., Rodriguez, V., Bhave, S., Hahn, R. T., Tison, G., Abreau, S. A., Barrios, J., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.05.029 · Cited by 153
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Chung, C. T., Lee, S., King, E., Liu, T., Armoundas, A. A., Bazoukis, G., & Tse, G. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00075-x · Cited by 79
Deep learning evaluation of biomarkers from echocardiogram videos
Hughes, J. W., Yuan, N., He, B., Ouyang, J., Ebinger, J., Botting, P., Lee, J., Theurer, J., Tooley, J. E., Nieman, K., et al. (2021) · EBioMedicine · doi:10.1016/j.ebiom.2021.103613 · Cited by 71
Metadata
- Authors
- Kwon, J.-M., Kim, K.-H., Akkus, Z., Jeon, K.-H., Park, J., & Oh, B.-H.
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 59
- Pages
- 151-157
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W3007330591
- Cited by
- 79
- References
- 9
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial intelligence for detecting mitral regurgitation using electrocardiography. https://app.cochat.ai/papers/10.1016/j.jelectrocard.2020.02.008
- The paper
- Kwon, J.-M., Kim, K.-H., Akkus, Z., Jeon, K.-H., Park, J., & Oh, B.-H. (2020). Artificial intelligence for detecting mitral regurgitation using electrocardiography. Journal of Electrocardiology. https://doi.org/10.1016/j.jelectrocard.2020.02.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.