A new, sensitive, and safe pretreatment method for the analysis of Cd(II) and Zn(II) ions in oil samples prior to flame atomic absorption spectrometry was developed. For the first time, a deep eutectic solvent is used as a disperser in reversed-phase dispersive liquid-liquid microextraction procedure. For this purpose, a deep eutectic solvent with low viscosity and miscible with both aqueous and organic phases is prepared by mixing glycolic acid and mandelic acid at a molar ratio of 2:1. The variables involved in this process were studied to provide high enrichment factors. Under optimized conditions, the linear ranges of calibration curves for Cd(II) and Zn(II) ions were obtained 0.30−20 and 0.50−30 μg L−1, respectively. The obtained detection limits and enrichment factors were 0.12 and 0.18 μg L−1; and 32.7 and 32.2 for Cd(II) and Zn(II), respectively. Repeatability of the proposed method, expressed as relative standard deviation, ranged from 2.7 to 4.1 % (n = 6, C = 1 μg L−1 of each cation). Finally, the proposed method was successfully applied for the determination of Cd(II) and Zn(II) concentrations in various oil samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Farajzadeh, M. A., Shahedi Hojghan, A., & Afshar Mogaddam, M. R. (2018) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2017.12.007 · Cited by 99
Self-citationLópez-García, I., Vicente-Martínez, Y., & Hernández-Córdoba, M. (2014) · Talanta · doi:10.1016/j.talanta.2014.02.011 · Cited by 87
Ali, J., Tuzen, M., & Kazi, T. G. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2019.125638 · Cited by 74
Naeemullah, & Tuzen, M. (2019) · Talanta · doi:10.1016/j.talanta.2018.12.027 · Cited by 70
Heidari, H., Ghanbari-Rad, S., & Habibi, E. (2020) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2019.103389 · Cited by 62
Research works printed but not linked: 30
- Abarshi, 2017, Bioaccumulation of heavy metals in some tissues of croaker fish from oil spilled rivers of Niger Delta region, Nigeria, Asian Pac. J. Trop. Biomed., 7, 563, 10.1016/j.apjtb.2017.05.008 · doi:10.1016/j.apjtb.2017.05.008
- Ansari, 2009, Variation in accumulation of heavy metals in different verities of sunflower seed oil with the aid of multivariate technique, Food Chem., 115, 318, 10.1016/j.foodchem.2008.11.051 · DOI
- Bakircioglu, 2013, Comparison of extraction induced by emulsion breaking, ultrasonic extraction and wet digestion procedures for determination of metals in edible oil samples in Turkey using ICP-OES, Food Chem., 138, 770, 10.1016/j.foodchem.2012.10.089 · DOI
- Bakkali, 2012, Determination of heavy metal content in vegetables and oils from Spain and morocco by inductively coupled plasma mass spectrometry, Anal. Lett., 45, 907, 10.1080/00032719.2012.655658 · DOI
- Cypriano, 2008, Ultrasound-assisted treatment of palm oil samples for the determination of copper and lead by stripping chronopotentiometry, Microchem. J., 90, 26, 10.1016/j.microc.2008.03.001 · DOI
- Dvorak, 2020, Vulnerability assessment of wild fish population to heavy metals in military training area: synthesis of a framework with example from Czech Republic, Ecol. Indic., 110, 10.1016/j.ecolind.2019.105920 · doi:10.1016/j.ecolind.2019.105920
- Fındık, 2017, Some chemical and microbiological properties of the butter and the butter oil produced from the same raw material, LWT Food Sci. Technol., 86, 233, 10.1016/j.lwt.2017.08.002 · doi:10.1016/j.lwt.2017.08.002
- Garballo-Rubio, 2017, A novel method for the determination of glycidyl and 3- monochloropropanediol esters in fish oil by gas chromatography tandem mass spectrometry, Talanta, 165, 267, 10.1016/j.talanta.2016.12.060 · doi:10.1016/j.talanta.2016.12.060
- Godoy-Caballero, 2013, New reversed phase dispersive liquid-liquid microextraction method for the determination of phenolic compounds in virgin olive oil by rapid resolution liquid chromathography with ultraviolet–visible and mass spectrometry detection, J. Chromatogr. A, 1313, 301
- Hashemi, 2010, Reversed-phase dispersive liquid-liquid microextraction with central composite design optimization for preconcentration and HPLC determination of oleuropein, Talanta, 80, 1926, 10.1016/j.talanta.2009.10.051 · DOI · Paper page
- Kalschne, 2020, Reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) as a green sample preparation method for multielement determination in fish oil by ICP-OES, Food Anal. Methods, 13, 230, 10.1007/s12161-019-01606-4 · DOI
- Kucukkolbasi, 2014, Monitoring of Zn(II), Cd(II), Pb(II) and Cu(II) during refining of some vegetable oils using differential pulse anodic stripping voltammetry, Food Anal. Methods, 7, 872, 10.1007/s12161-013-9694-5 · DOI
- Lahis Kalschne, 2020, A new and feasible analytical method using reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) for further determination of nickel in hydrogenated vegetable fat, Talanta, 208
- Liu, 2013, Development and comparison of two dispersive liquid–liquid microextraction techniques coupled to high performance liquid chromatography for the rapid analysis of bisphenol A in edible oils, J. Chromatogr. A, 1295, 16, 10.1016/j.chroma.2013.04.054 · DOI
- Llorent-Martínez, 2011, Investigation by ICP-MS of trace element levels in vegetable edible oils produced in Spain, Food Chem., 127, 1257, 10.1016/j.foodchem.2011.01.064 · DOI · Paper page
- Lourenço, 2019, A simple, rapid and low cost reversed-phase dispersive liquid-liquid microextraction for the determination of Na, K, Ca and Mg in biodiesel, Talanta, 199, 1, 10.1016/j.talanta.2019.02.054 · DOI
- Mendil, 2009, Investigation of the levels of some element in edible oil samples produced in Turkey by atomic absorption spectrometry, J. Hazard. Mater., 165, 724, 10.1016/j.jhazmat.2008.10.046 · DOI · Paper page
- Mohajer, 2020, Determination and health risk assessment of heavy metals in imported rice bran oil in Iran, J. Food Anal., 86
- Mohebbi, 2018, Determination of Cu, Cd, Ni, Pb and Zn in edible oils using reversed-phase ultrasonic assisted liquid-liquid microextraction and flame atomic absorption spectrometry, J. Anal. Chem., 73, 30, 10.1134/S1061934818010069 · DOI · Paper page
- Nunes, 2011, Multi-element determination of Cu, Fe, Ni and Zn content in vegetable oils samples by high-resolution continuum source atomic absorption spectrometry and microemulsion sample preparation, Food Chem., 127, 780, 10.1016/j.foodchem.2010.12.147 · DOI
- Özzeybek, 2020, Reverse phase dispersive liquid–liquid microextraction coupled to slotted quartz tube flame atomic absorption spectrometry as a new analytical strategy for trace determination of cadmium in fish and olive oil samples, J. Food Anal., 90
- Panhwar, 2017, Ultrasonic assisted dispersive liquid-liquid microextraction method based on deep eutectic solvent for speciation, preconcentration and determination of selenium species (IV) and (VI) in water and food samples, Talanta, 1751, 352, 10.1016/j.talanta.2017.07.063 · DOI
- Pereira, 2010, Determination of metals and metalloids in light and heavy crude oil by ICP-MS after digestion by microwave-induced combustion, Microchem. J., 96, 4, 10.1016/j.microc.2009.12.016 · doi:10.1016/j.microc.2009.12.016
- Pereira, 2016, Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry, Talanta, 150, 142, 10.1016/j.talanta.2015.12.036 · DOI
- Sahan, 2007, ICP-MS analysis of a series of metals (namely: Mg, Cr, Co, Ni, Fe, Cu, Zn, Sn, Cd and Pb) in black and green olive samples from Bursa, turkey, Food Chem., 105, 395, 10.1016/j.foodchem.2006.12.026 · DOI
- Schneider, 2017, Investigation of chemical modifiers for the determination of cadmium and chromium in fish oil and lipoid matrices using HR-CS GF AAS and a simple ‘dilute-and-shoot’ approach, Microchem. J., 133, 175, 10.1016/j.microc.2017.03.038 · DOI
- Sorouraddin, 2016, Combination of homogenous liquid-liquid extraction and dispersive liquid-liquid microextraction for extraction and preconcentration of amantadine from biological samples followed by its indirect determination by flame atomic absorption spectrometry, RSC Adv., 6, 108603, 10.1039/C6RA16572A · DOI · Paper page
- Sorouraddin, 2019, Development of a new method for extraction and preconcentration of cadmium and zinc ions in edible oils based on heat-induced homogeneous liquid-liquid microextraction, J. Iran. Chem. Soc., 16, 1537, 10.1007/s13738-019-01631-4 · DOI
- Sorouraddin, 2020, Development of dispersive liquid-liquid microextraction based on deep eutectic solvent using as complexing agent and extraction solvent: application for extraction of heavy metals, Sep. Sci. Technol., 10.1080/01496395.2019.1666874 · DOI
- von Schacky, 1999, The effect of dietary omega-3 fatty acids on coronary atherosclerosis. A randomized, double-blind, placebo-controlled trial, Ann. Intern. Med., 130, 554, 10.7326/0003-4819-130-7-199904060-00003 · DOI · Paper page
Cited by
Menthol-Based (Deep) Eutectic Solvents: A Review on Properties and Application in Extraction
Cherniakova, M., Varchenko, V., & Belikov, K. (2024) · The Chemical Record · doi:10.1002/tcr.202300267 · Cited by 83
Mafakheri, N., Shamsipur, M., & Babajani, N. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110010 · Cited by 47
Habila, M. A., AlMasoud, N., Alomar, T. S., AlOthman, Z. A., Yilmaz, E., & Soylak, M. (2020) · Molecules · doi:10.3390/molecules25204794 · Cited by 38
“[40] applied the deep eutectic solvent for the development of reversed-phase-based microextraction for the separation of cadmium and zinc.”
Sun, P., Wang, C., Li, S., Li, N., & Gao, Y. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-024-05304-x · Cited by 15
Karibayev, M., Tugelbay, S., Amankeldiyeva, A., Akilbekov, B., Ibrayem, T., Zhengis, A., Shah, D., Nurgalieva, D., & Baisalova, G. (2026) · Talanta · doi:10.1016/j.talanta.2026.129800 · Cited by 9
Metadata
- Authors
- Sorouraddin, S. M., Farajzadeh, M. A., & Okhravi, T.
- Venue
- Journal of Food Composition and Analysis
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 93
- Pages
- 103590
- ISSN
- 0889-1575 (ISSN-L)
- OpenAlex
- W3041291265
- Cited by
- 42
- References
- 6
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- University of Tabriz
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.