In situ deposited hierarchical CuO/NiO nanowall arrays film sensor with enhanced gas sensing performance to H2S
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Hierarchical and heterogeneous CuO/NiO nanowall arrays were in situ grown on ceramic tubes via a facile template-free hydrothermal route, and then were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and nitrogen adsorption-desorption techniques. The resultant composites exhibit network-like CuO/NiO array structures constructed by interconnected porous nanosheets, in which the decoration of CuO nanoparticles in NiO nanowall arrays was confirmed by XRD, XPS and TEM analyses. The 2.84 at % CuO decorated NiO sensor exhibits excellent sensing properties at 133 °C. The response to 5 ppm H2S attains 36.9, which increases as high as 5.6 times compared to the NiO one. The detection limit to H2S is further decreased from 1 ppb for the pure NiO sensor to 0.5 ppb. The CuO/NiO sensor shows a wide linear range from 50 to 1000 ppb, good repeatability, selectivity and long-term stability, which is expected to be a candidate for ppb-level H2S detection in real and complex environment of industrial production. Furthermore, the dominant H2S sensing mechanism is discussed from the view of the homo- and hierarchical architecture of the CuO/NiO arrays as well as the chemical and electronic sensitization effects of CuO decoration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
Resistance-based H2S gas sensors using metal oxide nanostructures: A review of recent advances
Mirzaei, A., Kim, S. S., & Kim, H. W. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.06.015 · Cited by 465
Hierarchical α-Fe2O3/NiO Composites with a Hollow Structure for a Gas Sensor
Wang, C., Cheng, X., Zhou, X., Sun, P., Hu, X., Shimanoe, K., Lu, G., & Yamazoe, N. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501063z · Cited by 283
Self-citationRoom temperature H2S gas sensor based on rather aligned ZnO nanorods with flower-like structures
Hosseini, Z. S., zad, A. I., & Mortezaali, A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.10.085 · Cited by 275
Li, Y., Luo, W., Qin, N., Dong, J., Wei, J., Li, W., Feng, S., Chen, J., Xu, J., Elzatahry, A. A., et al. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403817 · Cited by 274
Self-citationLi, Z., Wang, N., Lin, Z., Wang, J., Liu, W., Sun, K., Fu, Y. Q., & Wang, Z. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b02893 · Cited by 270
Li, Z., Huang, Y., Zhang, S., Chen, W., Kuang, Z., Ao, D., Liu, W., & Fu, Y. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2015.07.003 · Cited by 265
Sui, L.-L., Xu, Y.-M., Zhang, X.-F., Cheng, X.-L., Gao, S., Zhao, H., Cai, Z., & Huo, L.-H. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.10.138 · Cited by 236
Self-citationEnhanced H2S sensing characteristics of CuO-NiO core-shell microspheres sensors
Wang, Y., Qu, F., Liu, J., Wang, Y., Zhou, J., & Ruan, S. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.12.010 · Cited by 220
Xu, L., Zheng, R., Liu, S., Song, J., Chen, J., Dong, B., & Song, H. (2012) · Inorganic Chemistry · doi:10.1021/ic300749a · Cited by 210
Sui, L., Zhang, X., Cheng, X., Wang, P., Xu, Y., Gao, S., Zhao, H., & Huo, L. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b11754 · Cited by 191
Self-citationUltra-highly sensitive and selective H2S gas sensor based on CuO with sub-ppb detection limit
Li, D., Tang, Y., Ao, D., Xiang, X., Wang, S., & Zu, X. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2018.12.083 · Cited by 172
Wu, M., Zhang, X., Gao, S., Cheng, X., Rong, Z., Xu, Y., Zhao, H., & Huo, L. (2013) · CrystEngComm · doi:10.1039/c3ce41471j · Cited by 161
Self-citationHigh and fast H2S response of NiO/ZnO nanowire nanogenerator as a self-powered gas sensor
Qu, Z., Fu, Y., Yu, B., Deng, P., Xing, L., & Xue, X. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.058 · Cited by 147
Li, D., Qin, L., Zhao, P., Zhang, Y., Liu, D., Liu, F., Kang, B., Wang, Y., Song, H., Zhang, T., et al. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.110 · Cited by 131
One-pot hydrothermal synthesis of CuO–ZnO composite hollow spheres for selective H2S detection
Kim, S.-J., Na, C. W., Hwang, I.-S., & Lee, J. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.01.045 · Cited by 130
Na, H.-B., Zhang, X., Zhang, M., Deng, Z., Cheng, X., Huo, L.-H., & Gao, S. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126816 · Cited by 122
Self-citationHoang, N. V., Hung, C. M., Hòa, N. Đ., Duy, N. V., & Hiếu, N. V. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.07.084 · Cited by 117
Asad, M., & Sheikhi, M. H. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.021 · Cited by 115
A novel sensor for fast detection of triethylamine based on rutile TiO2 nanorod arrays
Hong-yan, Y., Cheng, X., Zhang, X., Zheng, Z., Tang, X., Xu, Y., Gao, S., Zhao, H., & Huo, L. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.08.092 · Cited by 107
Self-citationZnO-nanowire size effect induced ultra-high sensing response to ppb-level H2S
Chen, Y., Xu, P., Xu, T., Zheng, D., & Li, X. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.120 · Cited by 104
Enhanced H2S gas sensing performance of networked CuO-ZnO composite nanoparticle sensor
Park, S., Kim, S., Kheel, H., Hyun, S. K., Jin, C., & Lee, C. (2016) · Materials Research Bulletin · doi:10.1016/j.materresbull.2016.02.011 · Cited by 104
RF sputtered SnO2: NiO thin films as sub-ppm H2S sensor operable at room temperature
Kaur, M., Dadhich, B. K., Singh, R., KailasaGanapathi, Bagwaiya, T., Bhattacharya, S., Debnath, A. K., Muthe, K. P., & Gadkari, S. C. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.054 · Cited by 101
Kim, J., Mirzaei, A., Zheng, Y., Lee, J., Kim, J.-Y., Kim, H. W., & Kim, S. S. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.144 · Cited by 97
Li, Z., Wang, J., Wang, N., Yan, S., Liu, W., Fu, Y., & Wang, Z. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.07.218 · Cited by 92
Choi, S.-W., Katoch, A., Kim, J., & Kim, S. S. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5068222 · Cited by 89
Enhanced BTEX gas-sensing performance of CuO/SnO 2 composite
Ren, F., Gao, L., Yuan, Y., Zhang, Y., Alqrni, A., Al-Dossary, O. M., & Xu, J. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.09.140 · Cited by 78
Fe2O3 nanomaterials derived from Prussian blue with excellent H2S sensing properties
Guo, Y., Tian, X., Wang, X., & Sun, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.04.027 · Cited by 54
Yin, L., Qu, G., Guo, P., Zhang, R., Sun, J., & Chen, D. (2019) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2019.01.037 · Cited by 53
Park, S. H., Cai, Z., Lee, J., Yoon, J. I., & Chang, S. (2016) · Materials Letters · doi:10.1016/j.matlet.2016.06.043 · Cited by 48
Choi, S.-W., Katoch, A., Kim, J., & Kim, S. S. (2014) · Journal of Materials Chemistry C · doi:10.1039/c4tc01182a · Cited by 39
The Impact of Hydrogen Fuel Contaminates on Long-Term PMFC Performance
Garzón, F. H., Uribe, F. A., Rockward, T., Urdampilleta, I., & Brosha, E. L. (2006) · ECS Transactions · doi:10.1149/1.2356190 · Cited by 34
Zhong, X., Shen, Y., Zhao, S., Li, T., Lu, R., Yin, Y., Han, C., Wei, D., Zhang, Y., & Wei, K. (2019) · Vacuum · doi:10.1016/j.vacuum.2019.06.003 · Cited by 18
Cited by
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
“When their concentration exceeds a certain threshold, which is as low as 1 ppm, this causes indelible harm to human health and the environment [1–11].”
BackgroundLi, T., Yin, W., Gao, S., Sun, Y., Xu, P., Wu, S., Kong, H., Yang, G., & Wei, G. (2022) · Nanomaterials · doi:10.3390/nano12060982 · Cited by 222
Self-citationRecent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors
Wang, Y., & Zhou, Y. (2022) · Materials · doi:10.3390/ma15248728 · Cited by 180
“Metal oxide semiconductors (MOS) are popular sensing materials for gas detection, due to their low cost, high sensitivity, and good stability [30,31].”
BackgroundSilicon Nanowires for Gas Sensing: A Review
Akbari-Saatlu, M., Procek, M., Mattsson, C., Thungström, G., Nilsson, H.-E., Xiong, W., Xu, B., Li, Y., & Radamson, H. H. (2020) · Nanomaterials · doi:10.3390/nano10112215 · Cited by 159
“As an example, in many developing countries, evaluating the air quality is one of the most important tasks to bring new environmental solutions to avoid severe health hazards [10,11].”
Background
Metadata
- Authors
- Sui, L., Yu, T., Zhao, D., Cheng, X., Zhang, X., Wang, P., Xu, Y., Gao, S., Zhao, H., Gao, Y., & Huo, L.
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 385
- Pages
- 121570
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W2986744915
- Cited by
- 238
- References
- 33
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.