CoChat

Multiplexed Fc array for evaluation of antigen-specific antibody effector profiles

Open access
Brown, Eric P., Dowell, Karen G., Boesch, Austin W., Normandin, Erica, Mahan, Alison E., Chu, Thach, Barouch, Dan H., Bailey-Kellogg, Chris, Alter, Galit, Ackerman, Margaret E. · 2017 · Journal of Immunological Methods
Cited by 195

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Antibodies are widely considered to be a frequent primary and often mechanistic correlate of protection of approved vaccines; thus evaluating the antibody response is of critical importance in attempting to understand and predict the efficacy of novel vaccine candidates. Historically, antibody responses have been analyzed by determining the titer of the humoral response using measurements such as an ELISA, neutralization, or agglutination assays. In the simplest case, sufficiently high titers of antibody against vaccine antigen(s) are sufficient to predict protection. However, antibody titer provides only a partial measure of antibody function, which is dependent on both the variable region (Fv) to bind the antigen target, and the constant region (Fc) to elicit an effector response from the innate arm of the immune system. In the case of some diseases, such as HIV, for which an effective vaccine has proven elusive, antibody effector function has been shown to be an important driver of monoclonal antibody therapy outcomes, of viral control in infected patients, and of vaccine-mediated protection in preclinical and clinical studies. We sought to establish a platform for the evaluation of the Fc domain characteristics of antigen-specific antibodies present in polyclonal samples in order to better develop insights into Fc receptor-mediated antibody effector activity, more fully understand how antibody responses may differ in association with disease progression and between subject groups, and differentiate protective from non-protective responses. To this end we have developed a high throughput biophysical platform capable of simultaneously evaluating many dimensions of the antibody effector response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jim.2017.01.010

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 195

Metadata

Authors
Brown, E. P., Dowell, K. G., Boesch, A. W., Normandin, E., Mahan, A. E., Chu, T., Barouch, D. H., Bailey-Kellogg, C., Alter, G., & Ackerman, M. E.
Venue
Journal of Immunological Methods
Publisher
Elsevier BV
Published
2017-04
Volume
443
Pages
33-44
ISSN
0022-1759 (ISSN-L)
OpenAlex
W2585172252
Cited by
195
References
9
FWCI
7.57
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplexed Fc array for evaluation of antigen-specific antibody effector profiles. https://app.cochat.ai/papers/10.1016/j.jim.2017.01.010
The paper
Brown, E. P., Dowell, K. G., Boesch, A. W., Normandin, E., Mahan, A. E., Chu, T., Barouch, D. H., Bailey-Kellogg, C., Alter, G., & Ackerman, M. E. (2017). Multiplexed Fc array for evaluation of antigen-specific antibody effector profiles. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2017.01.010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.