The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair
Open accessAbstract
Abdominal wall hernias are one of the most common and long-standing surgical applications for biomaterials engineering. Yet, despite over 50 years of standard use of hernia repair materials, revision surgery is still required in nearly one third of patients due to hernia recurrence. To date, hernia mesh designs have focused on maximizing tensile strength to prevent structural failure of the implant. However, most recurrences occur at the biomaterial-tissue interface. There is a fundamental gap in understanding the degree to which a mechanical mismatch between hernia repair materials and host tissue contributes to failure at this interface. This review summarizes the current literature related to the anatomy and mechanics of both human and animal abdominal wall tissues, as well as the mechanical properties of many commonly-utilized hernia repair materials. The studies reviewed here reported greater compliance of the linea alba, larger strains for the intact abdominal wall, and greater stiffness for the rectus sheath and umbilical fascia when the tissues were loaded in the longitudinal direction compared to transverse. Additionally, greater stresses were observed in the linea alba when loaded in the transverse direction compared to longitudinal. Given these trends, a few recommendations can be made regarding orientation of mesh. The most compliant axis of the biomaterial should be oriented in the cranio-caudal (longitudinal) direction, and the strongest axis of the biomaterial should be oriented in the medial-lateral (transverse) direction. The human abdominal wall is also anisotropic, with anisotropy ratios as high as 8-9 reported for the human linea alba. Current biomaterial designs exhibit anisotropy ratios in the range of 1-3, and it is unclear whether an ideal ratio exists for optimal match between mesh and tissue. This is likely dependent on implantation location as the linea alba, rectus sheath, and other tissues of the abdominal wall exhibit different characteristics. Given the number of unknowns yet to be addressed by studies of the human abdominal wall, it is unlikely that any single biomaterial design currently encompasses all of the ideal features identified. More data on the mechanical properties of the abdominal wall will be needed to establish a full set of guidelines for ideal mesh mechanics including strength, compliance, anisotropy, nonlinearity and hysteresis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Burger, J. W. A., Luijendijk, R. W., Hop, W. C. J., Halm, J. A., Verdaasdonk, E. G. G., & Jeekel, J. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000141193.08524.e7 · Cited by 1,340
Epidemiology and cost of ventral hernia repair: making the case for hernia research
Poulose, B. K., Shelton, J., Phillips, S., Moore, D., Nealon, W., Penson, D., Beck, W., & Holzman, M. D. (2012) · Hernia · doi:10.1007/s10029-011-0879-9 · Cited by 914
Classification of biomaterials and their related complications in abdominal wall hernia surgery
Amid, P. K. (1997) · Hernia · doi:10.1007/bf02426382 · Cited by 751
Demographic and socioeconomic aspects of hernia repair in the United States in 2003
Rutkow, I. M. (2003) · Surgical Clinics of North America · doi:10.1016/s0039-6109(03)00132-4 · Cited by 716
European Hernia Society guidelines on the closure of abdominal wall incisions
Muysoms, F. E., Antoniou, S. A., Bury, K., Campanelli, G., Conze, J., Cuccurullo, D., de Beaux, A. C., Deerenberg, E. B., East, B., Fortelny, R. H., et al. (2015) · Hernia · doi:10.1007/s10029-014-1342-5 · Cited by 640
Normal Intraabdominal Pressure in Healthy Adults
Cobb, W. S., Burns, J. M., Kercher, K. W., Matthews, B. D., James Norton, H., & Todd Heniford, B. (2005) · Journal of Surgical Research · doi:10.1016/j.jss.2005.06.015 · Cited by 460
Foreign Body Reaction to Meshes Used for the Repair of Abdominal Wall Hernias
Klinge, B. K. (1999) · The European Journal of Surgery · doi:10.1080/11024159950189726 · Cited by 400
Brown, C., & Finch, J. (2010) · The Annals of The Royal College of Surgeons of England · doi:10.1308/003588410x12664192076296 · Cited by 386
The Argument for Lightweight Polypropylene Mesh in Hernia Repair
Cobb, W. S., Kercher, K. W., & Heniford, B. T. (2005) · Surgical Innovation · doi:10.1177/155335060501200109 · Cited by 364
Impact of Polymer Pore Size on the Interface Scar Formation in a Rat Model
Klinge, U., Klosterhalfen, B., Birkenhauer, V., Junge, K., Conze, J., & Schumpelick, V. (2002) · Journal of Surgical Research · doi:10.1006/jsre.2002.6358 · Cited by 340
Shrinking of polypropylene mesh in vivo: an experimental study in dogs
Klinge, U., Klosterhalfen, B., Müller, M., Öttinger, A. P., & Schumpelick, V. (2002) · The European Journal of Surgery · doi:10.1080/110241598750005156 · Cited by 279
K., J., U., K., A., P., P., G., M., N., & V., S. (2001) · Hernia · doi:10.1007/s100290100019 · Cited by 233
G., W., U., K., B., K., R., K., & V., S. (2001) · Hernia · doi:10.1007/s100290100017 · Cited by 219
Collagen Fibers in Linea Alba and Rectus Sheaths
Axer, H., Keyserlingk, D. G. V., & Prescher, A. (2001) · Journal of Surgical Research · doi:10.1006/jsre.2000.6070 · Cited by 167
Design strategies and applications of biomaterials and devices for Hernia repair
Kalaba, S., Gerhard, E. M., Winder, J. S., Pauli, E. M., Haluck, R. S., & Yang, J. Y. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.05.002 · Cited by 162
Xu, H., Wan, H., Sandor, M., Qi, S., Ervin, F., Harper, J. R., Silverman, R. P., & McQuillan, D. J. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0316 · Cited by 160
Deeken, C. R., Melman, L., Jenkins, E. D., Greco, S. C., Frisella, M. M., & Matthews, B. D. (2011) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2011.01.006 · Cited by 158
Self-citationDuBay, D. A., Choi, W., Urbanchek, M. G., Wang, X., Adamson, B., Dennis, R. G., Kuzon, W. M., & Franz, M. (2006) · Annals of Surgery · doi:10.1097/01.sla.0000251267.11012.85 · Cited by 157
Deeken, C. R., Abdo, M. S., Frisella, M. M., et al. (2010) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2010.09.012 · Cited by 145
Self-citationOrenstein, S. B., Saberski, E. R., Kreutzer, D. L., & Novitsky, Y. W. (2011) · Journal of Surgical Research · doi:10.1016/j.jss.2011.09.031 · Cited by 142
Deeken, C. R., & Matthews, B. D. (2013) · ISRN Surgery · doi:10.1155/2013/238067 · Cited by 139
Self-citationConze, J., Kingsnorth, A. N., Flament, J. B., Simmermacher, R., Arlt, G., Langer, C., Schippers, E., Hartley, M., & Schumpelick, V (2005) · British Journal of Surgery · doi:10.1002/bjs.5208 · Cited by 132
Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications
Martin, D. P., Badhwar, A., Shah, D. V., Rizk, S., Eldridge, S. N., Gagne, D. H., Ganatra, A., Darois, R. E., Williams, S. F., Tai, H.-C., et al. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2013.03.044 · Cited by 118
Anisotropy of human linea alba: A biomechanical study
Gräβel, D., Prescher, A., Fitzek, S., Keyserlingk, D. G., & Axer, H. (2005) · Journal of Surgical Research · doi:10.1016/j.jss.2004.10.010 · Cited by 115
Comparison of different methods for measuring intra-abdominal pressure
Gudmundsson, F. F., Viste, A., Gislason, H., et al. (2002) · Intensive Care Medicine · doi:10.1007/s00134-001-1187-0 · Cited by 114
Förstemann, T., Trzewik, J., Holste, J., Batke, B., Konerding, M. A., Wolloscheck, T., & Hartung, C. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.11.021 · Cited by 113
Hernández-Gascón, B., Peña, E., Melero, H., Pascual, G., Doblaré, M., Ginebra, M., Bellón, J. M., & Calvo, B. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.033 · Cited by 111
Hjort, H., Mathisen, T., Alves, A., Clermont, G., & Boutrand, J.-P. (2011) · Hernia · doi:10.1007/s10029-011-0885-y · Cited by 110
F., G., J., P., M., B.-S., F., C., A., S., S., T., & A., M. (2001) · Hernia · doi:10.1007/s100290100001 · Cited by 110
Measurement of the tensile strength of the ventral abdominal wall in comparison with scar tissue
Hollinsky, C., & Sandberg, S. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.06.002 · Cited by 109
Deeken, C. R., Eliason, B. J., Pichert, M. D., Grant, S. A., Frisella, M. M., & Matthews, B. D. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e3182445341 · Cited by 106
Self-citationDeeken, C. R., Faucher, K. M., & Matthews, B. D. (2011) · Surgical Endoscopy · doi:10.1007/s00464-011-1899-3 · Cited by 98
Self-citationMechanical characterization and constitutive modelling of the damage process in rectus sheath
Martins, P. A. L. D. S., Peña, E., Jorge, R. N., Santos, A., Santos, L., Mascarenhas, T., & Calvo, B. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.12.005 · Cited by 96
Anisotropic evaluation of synthetic surgical meshes
Saberski, E. R., Orenstein, S. B., & Novitsky, Y. W. (2010) · Hernia · doi:10.1007/s10029-010-0731-7 · Cited by 90
Hernández-Gascón, B., Peña, E., Pascual, G., Rodríguez, M., Calvo, B., Doblaré, M., & Bellón, J. M. (2010) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2010.11.012 · Cited by 86
Pascual, G., Rodríguez, M., Gómez‐Gil, V., García‐Honduvilla, N., Buján, J., & Bellón, J. M. (2008) · Surgery · doi:10.1016/j.surg.2008.04.005 · Cited by 78
Experimental study of the mechanical properties of human abdominal fascia
Doneva, M., Stoytchev, S., Pashkouleva, D., & Kavardzhikov, V. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.07.017 · Cited by 77
Scott, J. R., Deeken, C. R., Martindale, R. G., & Rosen, M. J. (2016) · Surgical Endoscopy · doi:10.1007/s00464-016-5057-9 · Cited by 75
Self-citationHollinsky, C., Sandberg, S., Koch, T., & Seidler, S. (2008) · Surgical Endoscopy · doi:10.1007/s00464-008-9936-6 · Cited by 69
Evaluation of various prosthetic materials and newer meshes for hernia repairs
Doctor, H. G. (2006) · Journal of Minimal Access Surgery · doi:10.4103/0972-9941.27721 · Cited by 66
Anurov, M., Titkova, S., & Oettinger, A. P. (2011) · Hernia · doi:10.1007/s10029-011-0877-y · Cited by 63
Ebersole, G. C., Buettmann, E. G., MacEwan, M. R., Tang, M. E., Frisella, M. M., Matthews, B. D., & Deeken, C. R. (2012) · Surgical Endoscopy · doi:10.1007/s00464-012-2258-8 · Cited by 62
Self-citationLevillain, A., Orhant, M., Turquier, F., & Hoc, T. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.04.006 · Cited by 60
Cavallo, J., Greco, S., Liu, J., Frisella, M., Deeken, C., & Matthews, B. D. (2013) · Hernia · doi:10.1007/s10029-013-1070-2 · Cited by 58
Self-citationCentral mesh recurrence after incisional hernia repair with Marlex - are the meshes strong enough?
Langer, C., Neufang, T., Kley, C. W., Liersch, T., & Heinz Becker, A. (2001) · Hernia · doi:10.1007/s100290100023 · Cited by 55
Tran, D., Podwojewski, F., Beillas, P., Otténio, M., Voirin, D., Turquier, F., & Mitton, D. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.03.001 · Cited by 54
Śmietański, M., Bury, K., Tomaszewska, A., Lubowiecka, I., & Szymczak, C. (2011) · Surgical Endoscopy · doi:10.1007/s00464-011-2056-8 · Cited by 53
Žuvela, M., Galun, D. A., Djurić-Stefanović, A., Palibrk, I., Petrović, M., & Milićević, M. (2013) · Hernia · doi:10.1007/s10029-013-1197-1 · Cited by 52
Deeken, C. R., Abdo, M. S., Frisella, M. M., & Matthews, B. D. (2011) · Surgical Endoscopy · doi:10.1007/s00464-010-1432-0 · Cited by 52
Self-citationLong-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects
Hernández-Gascón, B., Peña, E., Pascual, G., Rodrı́guez, M., Bellón, J. M., & Calvo, B. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.09.005 · Cited by 51
Voskerician, G., Gingras, P. H., & Anderson, J. M. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30481 · Cited by 50
Melman, L. M., Jenkins, E. D., Hamilton, N. A., Bender, L. C., Brodt, M. D., Deeken, C. R., Greco, S., Frisella, M. M., & Matthews, B. D. (2011) · Hernia · doi:10.1007/s10029-011-0787-z · Cited by 48
Self-citationAbdominal wall compliance after Marlex� mesh implantation for incisional hernia repair
M�ller, M., Klinge, U., Conze, J., & Schumpelick, V. (1998) · Hernia · doi:10.1007/bf01250024 · Cited by 47
Konerding, M. A., Chantereau, P., Delventhal, V., Holste, J., & Ackermann, M. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.09.022 · Cited by 47
Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension
Lyons, M., Winter, D. C., & Simms, C. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.03.009 · Cited by 45
Langenbach, M. R., Schmidt, J., Ubrig, B., & Zirngibl, H. (2008) · Surgical Endoscopy · doi:10.1007/s00464-008-9863-6 · Cited by 44
Kureshi, A. K., Vaiude, P., Nazhat, S. N., Petrie, A., & Brown, R. A. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.018 · Cited by 42
Active behavior of abdominal wall muscles: Experimental results and numerical model formulation
Grasa, J., Sierra, M., Lauzeral, N., Muñoz, M. J., Miana-Mena, F. J., & Calvo, B. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.04.013 · Cited by 36
Jenkins, E. D., Melman, L. M., Deeken, C. R., Greco, S., Frisella, M. M., & Matthews, B. D. (2011) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2010.12.006 · Cited by 32
Self-citationA non-biological model system to simulate the in vivo mechanical behavior of prosthetic meshes
Röhrnbauer, B., & Mazza, E. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.01.029 · Cited by 26
Majumder, A., Scott, J. R., & Novitsky, Y. W. (2016) · Surgical Innovation · doi:10.1177/1553350616656280 · Cited by 26
Comparison of Antibiotic-Coated versus Uncoated Porcine Dermal Matrix
Cohen, L. E., Imahiyerobo, T. A., Scott, J. R., & Spector, J. A. (2016) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000002688 · Cited by 12
Visco-elastic mechanical properties of human abdominal fascia
Doneva, M., Stoytchev, S., Pashkouleva, D., Tsenova, V. S., & Hristoskova, R. (2009) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2008.11.003 · Cited by 11
Cited by
Guo, R., Zhang, Q., Wu, Y., Chen, H., Liu, Y., Wang, J., Duan, X., Chen, Q., Ge, Z., & Zhang, Y. (2023) · Advanced Materials · doi:10.1002/adma.202212130 · Cited by 400
Capella-Monsonís, H., Crum, R. J., Hussey, G. S., & Badylak, S. F. (2024) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2024.115347 · Cited by 84
Roth, J. S., Anthone, G. J., Selzer, D. J., Poulose, B. K., Pierce, R. A., Bittner, J. G., Hope, W. W., Dunn, R. M., Martindale, R. G., Goldblatt, M. I., et al. (2021) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2020.12.002 · Cited by 40
Self-citationA Review of Advanced Abdominal Wall Hernia Patch Materials
Liang, K., Ding, C., Li, J., Yao, X., Yu, J., Wu, H., Chen, L., & Zhang, M. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303506 · Cited by 30
Metadata
- Authors
- Deeken, C. R., & Lake, S. P.
- Venue
- Journal of the Mechanical Behavior of Biomedical Materials
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 74
- Pages
- 411-427
- ISSN
- 1751-6161 (ISSN-L)
- OpenAlex
- W2611041248
- Cited by
- 258
- References
- 63
- FWCI
- 17.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.