OBJECTIVE To conduct a systematic review and meta-analysis to evaluate imaging methods used to diagnose adenomyosis. DATA SOURCES A thourough search was completed through the Cochrane Central Register of Controlled Trials, EMBASE, and PubMed/MEDLINE databases from January 2000 to June 2019. METHODS OF STUDY SELECTION Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool, studies reporting the diagnostic accuracy of an imaging method and histopathology as a reference standard were selected and prospecticvely registered in the International Prospective Register of Systematic Reviews (PROSPERO). Statistical analysis was performed using the R-package Meta-Analysis of Diagnostic Accuracy (mada). TABULATION, INTEGRATION, AND RESULTS Of 1,168 records identified, 10 studies were included in the meta-analysis and included 827 patients undergoing 2- or 3-dimensional (2D, 3D) transvaginal ultrasound (TVUS) and 317 patients undergoing magnetic resonance imaging (MRI). The risk of bias was "low" or "unclear" for all QUADAS domains. The overall prevalence of adenomyosis was 40%. Overall MRI, 2D-TVUS, 3D-TVUS, and TVUS had the following aggregated diagnostic qualities (95% confidence interval): sensitivity 78% (70%-84%), 74% (68%-79%), 84% (77%-89%), 78% (73%-82%), respectively; specificity 88% (83%-92%), 76% (71%-79%), 84% (77%-89%), 78% (74%-81%), respectively; positive likelihood ratio 6.8 (4.5%-10%), 3 (2.5%-3.7%), 5.2 (3.6%-7.4%), 3.5 (3%-4.2%), respectively; negative likelihood ratio 0.25 (0.18%-0.35%), 0.34 (0.27%-0.43%), 0.19 (0.13%-0.28%), 0.28 (0.23%-0.34%), respectively; pooled area under the operator curve 0.77, 0.7, 0.83, 0.73, respectively. The pooled area under the operator curve for all modalities was not significantly different (all: P ≥ .4). CONCLUSION As a result of the systemic review and meta-analysis, we identified TVUS and MRI as good and comparable non-invasive imaging methods for diagnosisng adenomayosis, leading us to recommend TVUS as the first-line diagnostic imagin method and MRI as second if TVUS is inconclusive.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jmig.2019.11.001

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Tellum, T., Nygaard, S., & Lieng, M.
Venue
Journal of Minimally Invasive Gynecology
Publisher
Elsevier BV
Published
2020-02
Volume
27
Issue
2
Pages
408-418.e3
ISSN
1553-4650 (ISSN-L)
OpenAlex
W2983644103
Cited by
149
References
6
FWCI
2.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.