CoChat

iDXA, Prodigy, and DPXL Dual-Energy X-ray Absorptiometry Whole-Body Scans: A Cross-Calibration Study

Open access
Hull, Holly, He, Qing, Thornton, John, Javed, Fahad, Allen, Lynn, Wang, Jack, Pierson, Richard N., Gallagher, Dympna · 2009 · Journal of Clinical Densitometry
Cited by 150

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Purpose Total body fat, lean, and bone mineral content (BMC) in addition to regional fat and lean mass values for arms, legs, and trunk were compared across a pencil-beam (Lunar DPX-L) and two fan-beam (GE Lunar Prodigy and GE Lunar iDXA) dual energy x-ray absorptiometry (DXA) systems. Methods Subjects were a multi-ethnic sample of 99 healthy adult males (47%) and females (mean ± SD: age 46.3 ± 16.9 yrs; weight 73.4±16.6 kg; height 167.6±9.7 cm; BMI 26.0±5.2 kg/m2) who had whole-body scans performed within a 3 hour period on the three systems. Repeated measures ANOVA was used to test the null hypothesis that the mean values for the three systems were equal. Translation equations between the methods were derived using regression techniques. Results BMC: For both genders, total BMC by iDXA was lower (P≤0.004) than the other systems. Lean: For males, iDXA was lower (P≤0.03) than the other systems for total, trunk and arms. For females, DPXL estimated higher (P<0.001) lean mass compared to the other systems for total, trunk and arms, but iDXA estimated greater legs lean mass. For both genders, all DPXL mean values were greater than Prodigy mean values (P<0.001). Fat: In females, all 3 systems were different from each other for total, trunk, and legs (P≤0.04). For arms, DPXL and iDXA were higher than Prodigy (P<0.0004). For males, DPXL was less (P<0.001) for total body, trunk and legs compared to the other two systems and greater than Prodigy only for arms (P<0.0007). These data were used to derive translation equations between systems. For several measurements, the differences between systems were related to gender. Conclusion For estimation of BMC and body composition, there was high agreement between all DXA systems (R2=0.85 to 0.99). Even so, cross-calibration equations should be used to examine data across systems to avoid erroneous conclusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jocd.2008.09.004

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 150

Metadata

Authors
Hull, H., He, Q., Thornton, J., Javed, F., Allen, L., Wang, J., Pierson, R. N., & Gallagher, D.
Venue
Journal of Clinical Densitometry
Publisher
Elsevier BV
Published
2009-01
Volume
12
Issue
1
Pages
95-102
ISSN
1094-6950 (ISSN-L)
OpenAlex
W1984379910
Cited by
113
References
17
FWCI
1.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.