Utilization of BIA-Derived Bone Mineral Estimates Exerts Minimal Impact on Body Fat Estimates via Multicompartment Models in Physically Active Adults
Abstract
The purpose of this study was to compare body fat estimates and fat-free mass (FFM) characteristics produced by multicompartment models when utilizing either dual energy X-ray absorptiometry (DXA) or single-frequency bioelectrical impedance analysis (SF-BIA) for bone mineral content (BMC) in a sample of physically active adults. Body fat percentage (BF%) was estimated with 5-compartment (5C), 4-compartment (4C), 3-compartment (3C), and 2-compartment (2C) models, and DXA. The 5C-Wang with DXA for BMC (i.e., 5C-Wang DXA) was the criterion. 5C-Wang using SF-BIA for BMC (i.e., 5C-Wang BIA), 4C-Wang DXA (DXA for BMC), 4C-Wang BIA (BIA for BMC), and 3C-Siri all produced values similar to 5C-Wang DXA (r > 0.99; total error [TE] < 0.83%; standard error of estimate < 0.67%; 95% limits of agreement [LOAs] < ±1.35%). The 2C models (2C-Pace, 2C-Siri, and 2C-Brozek) and DXA each produced similar standard error of estimate and 95% LOAs (2.13%-3.12% and ±4.15%-6.14%, respectively). Furthermore, 3C-Lohman DXA (underwater weighing for body volume and DXA for BMC) and 3C-Lohman BIA (underwater weighing for body volume and SF-BIA for BMC) produced the largest 95% LOAs (±5.94%-8.63%). The FFM characteristics (i.e., FFM density, water/FFM, mineral/FFM, and protein/FFM) for 5C-Wang DXA and 5C-Wang BIA were each compared with the "reference body" cadavers of Brozek et al. 5C-Wang BIA FFM density differed significantly from the "reference body" in women (1.103 ± 0.007 g/cm 3; p < 0.001), but no differences were observed for 5C-Wang DXA or either 5C model in men. Moreover, water/FFM and mineral/FFM were significantly lower in men and women when comparing 5C-Wang DXA and 5C-Wang BIA with the "reference body," whereas protein/FFM was significantly higher (all p ≤ 0.001). 3C-Lohman BIA and 3C-Lohman DXA produced error similar to 2C models and DXA and are therefore not recommended multicompartment models. Although more advanced multicompartment models (e.g., 4C-Wang and 5C-Wang) can utilize BIA-derived BMC with minimal impact on body fat estimates, the increased accuracy of these models over 3C-Siri is minimal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Other research has demonstrated that BIA-derived bone mineral content can be used in multi-compartment models in place of DXA.
“Previous research has also shown BIA scales to give inaccurate estimates of bone mineral content in comparison to DXA [59,60], while other research has demonstrated that BIA-derived bone mineral content can be used in multi-compartment models in place of DXA [61].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [61]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Flagged first, then by citations
Research works printed but not linked: 24
- Moon, 2009, Estimating body fat in NCAA Division I female athletes: a five-compartment model validation of laboratory methods, Eur J Appl Physiol, 105, 119, 10.1007/s00421-008-0881-9 · DOI
- Wang, 1998, Six-compartment body composition model: inter-method comparisons of total body fat measurement, Int J Obes Relat Metab Disord, 22, 329, 10.1038/sj.ijo.0800590 · DOI
- Wilson, 2013, Improved 4-compartment body-composition model for a clinically accessible measure of total body protein, Am J Clin Nutr, 97, 497, 10.3945/ajcn.112.048074 · DOI · Paper page
- Kyle, 2004, Bioelectrical impedance analysis. Part I. Review of principles and methods, Clin Nutr, 23, 1226, 10.1016/j.clnu.2004.06.004 · DOI · Paper page
- Patil, 2012, Estimation of bone mineral content from bioelectrical impedance analysis in Indian adults aged 23–81 years: a comparison with dual energy X-ray absorptiometry, Int J Biomed Eng Technol, 8, 99, 10.1504/IJBET.2012.045360 · DOI
- Stone, 2018, Comparison of bioelectrical impedance analysis and dual energy x-ray absorptiometry for estimating bone mineral content, Int J Sport Nutr Exerc Metab, 1
- LaForgia, 2008, Body composition: validity of segmental bioelectrical impedance analysis, Asia Pac J Clin Nutr, 17, 586
- Lohman, 1993, Multicomponent models in body composition research: opportunities and pitfalls, Basic Life Sci, 60, 53
- Wang, 2002, Multicomponent methods: evaluation of new and traditional soft tissue mineral models by in vivo neutron activation analysis, Am J Clin Nutr, 76, 968, 10.1093/ajcn/76.5.968 · DOI · Paper page
- Brozek, 1963, Densitometric analysis of body composition: revision of some quantitative assumptions, Ann N Y Acad Sci, 110, 113, 10.1111/j.1749-6632.1963.tb17079.x · DOI
- Booth, 2003, International physical activity questionnaire: 12-country reliability and validity, Med Sci Sports Exerc, 35, 1381, 10.1249/01.MSS.0000078924.61453.FB · DOI · Paper page
- Cheuvront, 2005, Hydration assessment of athletes, Sports Sci Exch, 18, 1
- Kavouras, 2002, Assessing hydration status, Curr Opin Clin Nutr Metab Care, 5, 519
- Heymsfield, 1989, Dual-photon absorptiometry: comparison of bone mineral and soft tissue mass measurements in vivo with established methods, Am J Clin Nutr, 49, 1283, 10.1093/ajcn/49.6.1283 · DOI
- Siri, 1961, Body composition from fluid spaces and density: analysis of methods, Tech Measuring Body Compost, 61, 223
- Hopkins, 2009, Progressive statistics for studies in sports medicine and exercise science, Med Sci Sports Exerc, 41, 3, 10.1249/MSS.0b013e31818cb278 · DOI · Paper page
- Tinsley, 2017, Proportional bias between dual-energy x-ray absorptiometry and bioelectrical impedance analysis varies based on sex in active adults consuming high- and low-carbohydrate diets, Nutr Res, 42, 85, 10.1016/j.nutres.2017.05.003 · DOI
- Fuller, 1992, Four-component model for the assessment of body composition in humans: comparison with alternative methods, and evaluation of the density and hydration of fat-free mass, Clin Sci, 82, 687, 10.1042/cs0820687 · DOI
- Prior, 2001, Muscularity and the density of the fat-free mass in athletes, J Appl Physiol, 90, 1523, 10.1152/jappl.2001.90.4.1523 · DOI
- Wang, 1998, Six-compartment body composition model: inter-method comparisons of total body fat measurement, Int J Obes Relat Metab Disord, 22, 10.1038/sj.ijo.0800590 · DOI
- Wang, 1999, Hydration of fat-free body mass: review and critique of a classic body-composition constant, Am J Clin Nutr, 69, 833, 10.1093/ajcn/69.5.833 · DOI
- Nickerson, 2017, Validity of selected bioimpedance equations for estimating body composition in men and women: a four-compartment model comparison, J Strength Cond Res, 31, 1963, 10.1519/JSC.0000000000001648 · DOI
- Tinsley, 2017, Impact of acute dietary manipulations on DXA and BIA body composition estimates, Med Sci Sports Exerc, 49, 823, 10.1249/MSS.0000000000001148 · DOI
- Wang, 1998, Six-compartment body composition model: inter-method comparisons of total body fat measurement, Int J Obes Relat Metab Disord, 22, 329, 10.1038/sj.ijo.0800590 · DOI
Cited by
Sorted by citations
Holmes, C. J., & Racette, S. B. (2021) · Nutrients · doi:10.3390/nu13082493 · Cited by 473
Metadata
- Authors
- Nickerson, B. S., & Tinsley, G. M.
- Affiliations
- Texas A&M International University (US)
- Texas Tech University (US)
- Corresponding author
- Nickerson, Brett S.
- Venue
- Journal of Clinical Densitometry
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 21
- Issue
- 4
- Pages
- 541-549
- ISSN
- 1094-6950 (ISSN-L)
- OpenAlex
- W2794193368
- Cited by
- 31
- References
- 1
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 2 · 2022: 5 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 5
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Densitometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Infectious Diseases › HIV-related health complications and treatments
- Keywords
- dual-energy X-ray absorptiometry, bone mineral content, body fat percentage, fat-free mass, physically active adults, underwater weighing
- MeSH terms
- Adolescent, Adult, Female, Humans, Male, Reproducibility of Results, Exercise, Absorptiometry, Photon, Bone Density, Body Mass Index, Electric Impedance, Body Fat Distribution, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review