Cited by 31Body Composition Measurement TechniquesBone health and osteoporosis researchHIV-related health complications and treatments

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Utilization of BIA-Derived Bone Mineral Estimates Exerts Minimal Impact on Body Fat Estimates via Multicompartment Models in Physically Active Adults

Nickerson, Brett S., Tinsley, Grant M.·2018·Journal of Clinical Densitometry

Abstract

The purpose of this study was to compare body fat estimates and fat-free mass (FFM) characteristics produced by multicompartment models when utilizing either dual energy X-ray absorptiometry (DXA) or single-frequency bioelectrical impedance analysis (SF-BIA) for bone mineral content (BMC) in a sample of physically active adults. Body fat percentage (BF%) was estimated with 5-compartment (5C), 4-compartment (4C), 3-compartment (3C), and 2-compartment (2C) models, and DXA. The 5C-Wang with DXA for BMC (i.e., 5C-Wang DXA) was the criterion. 5C-Wang using SF-BIA for BMC (i.e., 5C-Wang BIA), 4C-Wang DXA (DXA for BMC), 4C-Wang BIA (BIA for BMC), and 3C-Siri all produced values similar to 5C-Wang DXA (r > 0.99; total error [TE] < 0.83%; standard error of estimate < 0.67%; 95% limits of agreement [LOAs] < ±1.35%). The 2C models (2C-Pace, 2C-Siri, and 2C-Brozek) and DXA each produced similar standard error of estimate and 95% LOAs (2.13%-3.12% and ±4.15%-6.14%, respectively). Furthermore, 3C-Lohman DXA (underwater weighing for body volume and DXA for BMC) and 3C-Lohman BIA (underwater weighing for body volume and SF-BIA for BMC) produced the largest 95% LOAs (±5.94%-8.63%). The FFM characteristics (i.e., FFM density, water/FFM, mineral/FFM, and protein/FFM) for 5C-Wang DXA and 5C-Wang BIA were each compared with the "reference body" cadavers of Brozek et al. 5C-Wang BIA FFM density differed significantly from the "reference body" in women (1.103 ± 0.007 g/cm 3; p < 0.001), but no differences were observed for 5C-Wang DXA or either 5C model in men. Moreover, water/FFM and mineral/FFM were significantly lower in men and women when comparing 5C-Wang DXA and 5C-Wang BIA with the "reference body," whereas protein/FFM was significantly higher (all p ≤ 0.001). 3C-Lohman BIA and 3C-Lohman DXA produced error similar to 2C models and DXA and are therefore not recommended multicompartment models. Although more advanced multicompartment models (e.g., 4C-Wang and 5C-Wang) can utilize BIA-derived BMC with minimal impact on body fat estimates, the increased accuracy of these models over 3C-Siri is minimal.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.jocd.2018.02.003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other research has demonstrated that BIA-derived bone mineral content can be used in multi-compartment models in place of DXA.

    “Previous research has also shown BIA scales to give inaccurate estimates of bone mineral content in comparison to DXA [59,60], while other research has demonstrated that BIA-derived bone mineral content can be used in multi-compartment models in place of DXA [61].”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 24

  1. Moon, 2009, Estimating body fat in NCAA Division I female athletes: a five-compartment model validation of laboratory methods, Eur J Appl Physiol, 105, 119, 10.1007/s00421-008-0881-9 · DOI
  2. Wang, 1998, Six-compartment body composition model: inter-method comparisons of total body fat measurement, Int J Obes Relat Metab Disord, 22, 329, 10.1038/sj.ijo.0800590 · DOI
  3. Wilson, 2013, Improved 4-compartment body-composition model for a clinically accessible measure of total body protein, Am J Clin Nutr, 97, 497, 10.3945/ajcn.112.048074 · DOI · Paper page
  4. Kyle, 2004, Bioelectrical impedance analysis. Part I. Review of principles and methods, Clin Nutr, 23, 1226, 10.1016/j.clnu.2004.06.004 · DOI · Paper page
  5. Patil, 2012, Estimation of bone mineral content from bioelectrical impedance analysis in Indian adults aged 23–81 years: a comparison with dual energy X-ray absorptiometry, Int J Biomed Eng Technol, 8, 99, 10.1504/IJBET.2012.045360 · DOI
  6. Stone, 2018, Comparison of bioelectrical impedance analysis and dual energy x-ray absorptiometry for estimating bone mineral content, Int J Sport Nutr Exerc Metab, 1
  7. LaForgia, 2008, Body composition: validity of segmental bioelectrical impedance analysis, Asia Pac J Clin Nutr, 17, 586
  8. Lohman, 1993, Multicomponent models in body composition research: opportunities and pitfalls, Basic Life Sci, 60, 53
  9. Wang, 2002, Multicomponent methods: evaluation of new and traditional soft tissue mineral models by in vivo neutron activation analysis, Am J Clin Nutr, 76, 968, 10.1093/ajcn/76.5.968 · DOI · Paper page
  10. Brozek, 1963, Densitometric analysis of body composition: revision of some quantitative assumptions, Ann N Y Acad Sci, 110, 113, 10.1111/j.1749-6632.1963.tb17079.x · DOI
  11. Booth, 2003, International physical activity questionnaire: 12-country reliability and validity, Med Sci Sports Exerc, 35, 1381, 10.1249/01.MSS.0000078924.61453.FB · DOI · Paper page
  12. Cheuvront, 2005, Hydration assessment of athletes, Sports Sci Exch, 18, 1
  13. Kavouras, 2002, Assessing hydration status, Curr Opin Clin Nutr Metab Care, 5, 519
  14. Heymsfield, 1989, Dual-photon absorptiometry: comparison of bone mineral and soft tissue mass measurements in vivo with established methods, Am J Clin Nutr, 49, 1283, 10.1093/ajcn/49.6.1283 · DOI
  15. Siri, 1961, Body composition from fluid spaces and density: analysis of methods, Tech Measuring Body Compost, 61, 223
  16. Hopkins, 2009, Progressive statistics for studies in sports medicine and exercise science, Med Sci Sports Exerc, 41, 3, 10.1249/MSS.0b013e31818cb278 · DOI · Paper page
  17. Tinsley, 2017, Proportional bias between dual-energy x-ray absorptiometry and bioelectrical impedance analysis varies based on sex in active adults consuming high- and low-carbohydrate diets, Nutr Res, 42, 85, 10.1016/j.nutres.2017.05.003 · DOI
  18. Fuller, 1992, Four-component model for the assessment of body composition in humans: comparison with alternative methods, and evaluation of the density and hydration of fat-free mass, Clin Sci, 82, 687, 10.1042/cs0820687 · DOI
  19. Prior, 2001, Muscularity and the density of the fat-free mass in athletes, J Appl Physiol, 90, 1523, 10.1152/jappl.2001.90.4.1523 · DOI
  20. Wang, 1998, Six-compartment body composition model: inter-method comparisons of total body fat measurement, Int J Obes Relat Metab Disord, 22, 10.1038/sj.ijo.0800590 · DOI
  21. Wang, 1999, Hydration of fat-free body mass: review and critique of a classic body-composition constant, Am J Clin Nutr, 69, 833, 10.1093/ajcn/69.5.833 · DOI
  22. Nickerson, 2017, Validity of selected bioimpedance equations for estimating body composition in men and women: a four-compartment model comparison, J Strength Cond Res, 31, 1963, 10.1519/JSC.0000000000001648 · DOI
  23. Tinsley, 2017, Impact of acute dietary manipulations on DXA and BIA body composition estimates, Med Sci Sports Exerc, 49, 823, 10.1249/MSS.0000000000001148 · DOI
  24. Wang, 1998, Six-compartment body composition model: inter-method comparisons of total body fat measurement, Int J Obes Relat Metab Disord, 22, 329, 10.1038/sj.ijo.0800590 · DOI

Cited by

Sorted by citations

Metadata

Authors
Nickerson, B. S., & Tinsley, G. M.
Affiliations
  • Texas A&M International University (US)
  • Texas Tech University (US)
Corresponding author
Nickerson, Brett S.
Venue
Journal of Clinical Densitometry
Publisher
Elsevier BV
Published
2018-10
Volume
21
Issue
4
Pages
541-549
ISSN
1094-6950 (ISSN-L)
OpenAlex
W2794193368
Cited by
31
References
1
Citations by year
2025: 1 · 2024: 4 · 2023: 2 · 2022: 5 · 2021: 3 · 2020: 6 · 2019: 5 · 2018: 5
FWCI
3.28
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Clinical Densitometry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Infectious Diseases › HIV-related health complications and treatments
Keywords
dual-energy X-ray absorptiometry, bone mineral content, body fat percentage, fat-free mass, physically active adults, underwater weighing
MeSH terms
Adolescent, Adult, Female, Humans, Male, Reproducibility of Results, Exercise, Absorptiometry, Photon, Bone Density, Body Mass Index, Electric Impedance, Body Fat Distribution, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review