Inner filter effect in fluorescence spectroscopy: As a problem and as a solution
The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
This article discusses three aspects of inner filter effect (IFE) in fluorescence spectroscopy. (i) First, IFE as undesirable in fluorescence measurements: IFE results in non-linear fluorescence response of the analyte under study and it has been verified that IFE cannot be eliminated; it can either be minimized or corrected for intensity loss. Over the years, researchers have proposed many intensity correction methods to avoid IFE related issues. Often analysts using fluorescence spectroscopy, knowingly or unknowingly, ignore IFE or use an inappropriate intensity correction method. Herein, we have highlighted the basis and significances of various correction models that are proposed since 1970s to till date. (ii) Second, IFE mediated concentration dependent red shift (CDRS) as an analytical tool: the conventional fluorescence measurements and IFE correction strategies cannot be applied in analysis of optically dense multi-fluorophoric samples like oils, petrochemicals, biological samples and food samples etc. The strategy for exclusive inclusion of IFE and IFE induced CDRS as characteristics of the system for development of fluorescence based assay, towards maximizing fluorescence sensitivity of optically dense multi-fluorophoric systems, have been discussed. (iii) Third, IFE based sensing: when the sample contains chromophores, which absorb either at the excitation or at the emission wavelength range of the fluorophore, then the chromophores act as a filter. Thus tuning either the absorber or fluorophore concentration will lead to development of fluorescence based assay for a selective analyte. Principles and protocols are described to identify whether a sensing event is due to IFE or any other fluorescence mechanism. Additionally, a brief description is given on advanced findings and progresses made in sensing of for various classes of analytes in the recent past, using IFE concept. The second and third aspect combined together serve as a tool towards enhancing sensitivity of fluorescence measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Molecular Fluorescence: Principles and Applications
Valeur, B., & Berberan‐Santos, M. N. (2012) · Wiley eBooks · doi:10.1002/9783527650002 · Cited by 4,098
Fluorescence spectroscopy and multi-way techniques. PARAFAC
Murphy, K. R., Stedmon, C. A., Graeber, D., & Bro, R. (2013) · Analytical Methods · doi:10.1039/c3ay41160e · Cited by 2,060
Ohno, T. (2002) · Environmental Science & Technology · doi:10.1021/es0155276 · Cited by 1,619
The quenching of the fluorescence of carbon dots: A review on mechanisms and applications
Zu, F., Yan, F., Bai, Z., Xu, J., Wang, Y., Huang, Y., & Zhou, X. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2318-9 · Cited by 1,602
Murphy, K. R., Butler, K. D., Spencer, R. G. M., Stedmon, C. A., Boehme, J. R., & Aiken, G. R. (2010) · Environmental Science & Technology · doi:10.1021/es102362t · Cited by 753
Gauthier, T. D., Shane, E. C., Guerin, W. F., Seitz, W. R., & Grant, C. L. (1986) · Environmental Science & Technology · doi:10.1021/es00153a012 · Cited by 598
Experimental correction for the inner-filter effect in fluorescence spectra
Kubista, M., Sjöback, R., Eriksson, S., & Albinsson, B. (1994) · The Analyst · doi:10.1039/an9941900417 · Cited by 402
Inner filter correction of dissolved organic matter fluorescence
Kothawala, D. N., Murphy, K. R., Stedmon, C. A., Weyhenmeyer, G. A., & Tranvik, L. J. (2013) · Limnology and Oceanography: Methods · doi:10.4319/lom.2013.11.616 · Cited by 373
UV–VIS absorption spectroscopy: Lambert-Beer reloaded
Mäntele, W., & Deniz, E. (2017) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2016.09.037 · Cited by 341
Amino-Functionalized Al–MOF for Fluorescent Detection of Tetracyclines in Milk
Li, C., Zhu, L., Yang, W., Xie, H., Zhao, S., Zhang, X., Tang, W., Wang, J., Yue, T., & Li, Z. (2019) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.8b06253 · Cited by 338
Smartphone Fluorescence Spectroscopy
Yu, H., Tan, Y., & Cunningham, B. T. (2014) · Analytical Chemistry · doi:10.1021/ac502080t · Cited by 281
Quantum dot enabled detection of Escherichia coli using a cell-phone
Zhu, H., Sikora, U., & Ozcan, A. (2012) · The Analyst · doi:10.1039/c2an35071h · Cited by 277
Müller, M. G., Georgakoudi, I., Zhang, Q., Wu, J., & Feld, M. S. (2001) · Applied Optics · doi:10.1364/ao.40.004633 · Cited by 256
Correction for light absorption in fluorescence studies of protein-ligand interactions
Birdsall, B., King, R. W., Wheeler, M. R., Lewis, C. A., Goode, S. R., Dunlap, R. B., & Roberts, G. C. K. (1983) · Analytical Biochemistry · doi:10.1016/0003-2697(83)90020-9 · Cited by 255
Fluorescence of Dyes in Solutions with High Absorbance. Inner Filter Effect Correction
Fonin, A. V., Sulatskaya, A. I., Kuznetsova, I. M., & Turoverov, K. K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103878 · Cited by 248
Current status and prospects on chemical structure driven photoluminescence behaviour of carbon dots
Barman, M. K., & Patra, A. (2018) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2018.08.001 · Cited by 239
Bhatt, S., Bhatt, M., Kumar, A., Vyas, G., Gajaria, T., & Paul, P. (2018) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2018.04.008 · Cited by 235
Fluorescence spectroscopy and chemometrics in the food classification - a review
Sádecká, J., & Tóthová, J. (2007) · Czech Journal of Food Sciences · doi:10.17221/687-cjfs · Cited by 213
Meng, X., Chang, Q. M., Xue, C., Yang, J., & Hu, S. (2017) · Chemical Communications · doi:10.1039/c7cc00461c · Cited by 213
Gong, P., Sun, L., Wang, F., Liu, X., Yan, Z., Wang, M., Zhang, L., Tian, Z., Liu, Z., & You, J. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.09.100 · Cited by 204
Fluorescence spectrometry. A review
Parker, C. A., & Rees, W. T. (1962) · The Analyst · doi:10.1039/an9628700083 · Cited by 188
Larsson, T., Wedborg, M., & Turner, D. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.09.067 · Cited by 174
Zhang, Y., Fang, X., Zhao, H., & Li, Z. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.027 · Cited by 164
Miao, H., Wang, Y., & Yang, X. (2018) · Nanoscale · doi:10.1039/c8nr02405g · Cited by 150
Xiao, N., Liu, S. G., Mo, S., Li, N., Ju, Y. J., Yu, L. D., Li, N. B., & Luo, H. Q. (2018) · Talanta · doi:10.1016/j.talanta.2018.02.114 · Cited by 144
Singh, A. K., Singh, V. K., Singh, M., Singh, P., Khadim, S. R., Singh, U., Koch, B., Hasan, S. H., & Asthana, R. K. (2019) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2019.02.023 · Cited by 143
Wang, M., Wan, Y., Zhang, K., Fu, Q., Wang, L., Zeng, J., Xia, Z., & Gao, D. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01712-6 · Cited by 141
Sorensen, J., Vivanco, A., Ascott, M., Gooddy, D. C., Lapworth, D. J., Read, D. S., Rushworth, C. M., Bucknall, J., Herbert, K., Karapanos, I., et al. (2018) · Water Research · doi:10.1016/j.watres.2018.03.001 · Cited by 128
Assessment of inner filter effect corrections in fluorimetry
Puchalski, M. M., Morra, M. J., & von Wandruszka, R. (1991) · Fresenius Journal of Analytical Chemistry · doi:10.1007/bf00321578 · Cited by 127
Sulatskaya, A. I., Lavysh, A. V., Maskevich, A. A., Kuznetsova, I. М., & Константинович, Т. К. (2017) · Scientific Reports · doi:10.1038/s41598-017-02237-7 · Cited by 122
Tanwar, A. S., Adil, L. R., Afroz, M. A., & Iyer, P. K. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00093 · Cited by 114
Guo, X., Yue, G., Huang, J., Liu, C., Zeng, Q., & Wang, L. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b10529 · Cited by 113
Carbogenic nanodots derived from organo-templated zeolites with modulated full-color luminescence
Mu, Y., Wang, N., Sun, Z., Wang, J., Li, J., & Yu, J. (2016) · Chemical Science · doi:10.1039/c6sc00085a · Cited by 109
Qian, S., Qiao, L., Xu, W., Jiang, K., Wang, Y., & Lin, H. (2018) · Talanta · doi:10.1016/j.talanta.2018.10.097 · Cited by 109
Smith, J. A., Singh‐Wilmot, M. A., Carter, K. P., Cahill, C. L., & Ridenour, J. A. (2018) · Crystal Growth & Design · doi:10.1021/acs.cgd.8b01426 · Cited by 109
Synchronous fluorescence spectrometry: Conformational investigation or inner filter effect?
Pacheco, M. E., & Bruzzone, L. (2013) · Journal of Luminescence · doi:10.1016/j.jlumin.2012.12.056 · Cited by 100
Boron doped carbon dots as a multifunctional fluorescent probe for sorbate and vitamin B12
Jia, Y. F., Hu, Y., Li, Y., Zeng, Q., Jiang, X., & Cheng, Z. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3196-5 · Cited by 100
Das, P., Ganguly, S., Bose, M., Ray, D., Ghosh, S., Mondal, S., Aswal, V. K., Das, A. K., Banerjee, S., & Das, N. C. (2019) · New Journal of Chemistry · doi:10.1039/c8nj06308g · Cited by 92
Tawfik, S. M., Sharipov, M., Kakhkhorov, S. A., Elmasry, M. R., & Lee, Y. (2018) · Advanced Science · doi:10.1002/advs.201801467 · Cited by 87
Li, N., Liu, S. G., Fan, Y. Z., Ju, Y. J., Xiao, N., Luo, H. Q., & Li, N. B. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.01.049 · Cited by 84
Du, F., Li, G., Gong, X., Guo, Z., Shuang, S., Xian, M., & Dong, C. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.027 · Cited by 83
Singh, V. K., Singh, V., Yadav, P. K., Chandra, S., Bano, D., Kumar, V., Koch, B., Talat, M., & Hasan, S. H. (2018) · New Journal of Chemistry · doi:10.1039/c8nj02126k · Cited by 79
Xiao, N., Liu, S. G., Mo, S., Yang, Y. Z., Han, L., Ju, Y. J., Li, N. B., & Luo, H. Q. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.097 · Cited by 75
Prediction of Cell Culture Media Performance Using Fluorescence Spectroscopy
Ryan, P. W., Li, B., Shanahan, M., Leister, K. J., & Ryder, A. G. (2010) · Analytical Chemistry · doi:10.1021/ac902337c · Cited by 73
Li, C., Liu, W., Sun, X., Pan, W., Yu, G., & Wang, J. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.02.050 · Cited by 72
Tanwar, A. S., Patidar, S., Ahirwar, S. K., Dehingia, S., & Iyer, P. K. (2018) · The Analyst · doi:10.1039/c8an01970c · Cited by 72
Jiang, N., Li, G., Che, W., Zhu, D., Su, Z., & Bryce, M. R. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04250k · Cited by 69
Jiang, K., Luo, S., Pang, C., Wang, B., Wu, H., & Wang, Z. (2018) · Dyes and Pigments · doi:10.1016/j.dyepig.2018.10.041 · Cited by 69
Gong, P., Zhang, L., Yuan, X., Liu, X., Diao, X., Zhao, Q., Tian, Z., Sun, J., Liu, Z., & You, J. (2018) · Dyes and Pigments · doi:10.1016/j.dyepig.2018.10.031 · Cited by 68
Wei, J., Yang, Y. P., Dong, J., Wang, S., & Li, P. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3175-x · Cited by 64
A Comparison of Fluorescence Inner-Filter Effects for Different Cell Configurations
Kao, S., Asanov, A. N., & Oldham, P. B. (1998) · Instrumentation Science & Technology · doi:10.1080/10739149808001906 · Cited by 63
Fang, B., Lu, X., Hu, J., Zhang, G., Zheng, X., He, L., Cao, J., Gu, J. J., & Cao, F. (2018) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2018.10.088 · Cited by 63
Panigrahi, A., Sahu, B. P., Mandani, S., Nayak, D., Giri, S., & Sarma, T. K. (2019) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2019.01.029 · Cited by 63
Liu, Q., Yan, X., Lai, Q., & Su, X. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.040 · Cited by 62
Correction for inner filter effects in turbid samples: fluorescence assays of mitochondrial NADH
French, S. A., Territo, P. R., & Balaban, R. S. (1998) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1998.275.3.c900 · Cited by 59
Surface Modifications for Photon-Upconversion-Based Energy-Transfer Nanoprobes
Andresen, E., Resch‐Genger, U., & Schäferling, M. (2019) · Langmuir · doi:10.1021/acs.langmuir.9b00238 · Cited by 59
A fluorometric paper test for chromium(VI) based on the use of N-doped carbon dots
Lu, K.-H., Lin, J.-H., Lin, C.-Y., Chen, C., & Yeh, Y.-C. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3337-5 · Cited by 57
Zhong, Y., Xue, F., Wei, P., Li, R., Cao, C., & Yi, T. (2018) · Nanoscale · doi:10.1039/c8nr05549a · Cited by 55
Insights into gold nanoparticles as a mucoadhesive system
Ouellette, M., Masse, F., Lefebvre-Demers, M., Maestracci, Q., Grenier, P., Millar, R. P., Bertrand, N., PRIETO, M. J. E., & Boisselier, É. (2018) · Scientific Reports · doi:10.1038/s41598-018-32699-2 · Cited by 54
Chen, H., Lu, Q., He, K., Liu, M., Zhang, Y., & Yao, S. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.085 · Cited by 51
Yang, Y., Hou, J., Huo, D., Wang, X., Li, J., Xu, G., Bian, M., He, Q., Hou, C., & Yang, M. J. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3361-5 · Cited by 51
Cao, M., Li, Y., Zhao, Y., Shen, C., Zhang, H., & Huang, Y. (2019) · RSC Advances · doi:10.1039/c9ra00290a · Cited by 49
Panigrahi, S. K., & Mishra, A. K. (2019) · Photochemical & Photobiological Sciences · doi:10.1039/c8pp00498f · Cited by 47
Lu, H., Yu, C., Zhang, Y., & Xu, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.10.025 · Cited by 44
Wang, L., Cao, H., Pan, C.-G., He, Y., Liu, H., Zhou, L.-H., Li, C.-Q., & Liang, G. (2018) · Microchimica Acta · doi:10.1007/s00604-018-3153-3 · Cited by 44
Gong, X., Wang, H., Liu, Y., Hu, Q., Gao, Y., Yang, Z., Shuang, S., & Dong, C. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.01.012 · Cited by 44
Riesz, J., Gilmore, J., & Meredith, P. (2005) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2004.08.014 · Cited by 43
Chen, B., Chai, S., Liu, J., Liu, C., Li, Y., He, J., Yu, Z., Yang, T., Feng, C., & Huang, C. Z. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01670-z · Cited by 43
Correction of Inner Filter Effect in Mirror Coating Cells for Trace Level Fluorescence Measurements
Fanget, B., Devos, O., & Draye, M. (2003) · Analytical Chemistry · doi:10.1021/ac0262255 · Cited by 42
Real‐Time compensation of the inner filter effect in high‐density bioluminescent cultures
Konstantinov, K. B., Dhurjati, P., Dyk, T. K. V., Majarian, W. R., & LaRossa, R. A. (1993) · Biotechnology and Bioengineering · doi:10.1002/bit.260421009 · Cited by 40
de Oliveira, G. F., Bertone, E., Stewart, R. A., Awad, J., Holland, A., O’Halloran, K., & Bird, S. (2018) · Water · doi:10.3390/w10091146 · Cited by 38
Tarai, M., & Mishra, A. K. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.08.041 · Cited by 37
Lewkowicz, A., Bojarski, P., Synak, A., Grobelna, B., Akopova, I., Gryczyński, I., & Kułak, L. (2012) · The Journal of Physical Chemistry C · doi:10.1021/jp3022562 · Cited by 36
Dialysed caramel as an effective fluorophore for the simultaneous detection of three nitrophenols
Ma, J., Bian, L., Zhao, L., Feng, X., Zhao, L., Wang, Z., & Pu, Q. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.006 · Cited by 36
Zhang, F., He, X., Ma, P., Sun, Y. X., Wang, X., & Song, D. (2018) · Talanta · doi:10.1016/j.talanta.2018.07.031 · Cited by 34
Ryder, A. G., Stedmon, C. A., Harrit, N., & Bro, R. (2017) · Pure and Applied Chemistry · doi:10.1515/pac-2017-0610 · Cited by 32
Hu, L., Zhang, Q., Gan, X., Yin, W., & Fu, W. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1374-2 · Cited by 32
Tang, D., Zhang, J., Zhou, R., Xie, Y., Hou, X., Xu, K., & Wu, P. (2018) · Nanoscale · doi:10.1039/c8nr01355a · Cited by 31
Li, C., Zhao, J., Chen, Y., Wang, X., Sun, X., Pan, W., Yu, G., Yan, Z., & Wang, J. (2018) · The Analyst · doi:10.1039/c8an00962g · Cited by 31
Fluorescence-tunable copper nanoclusters and their application in hexavalent chromium sensing
Lin, Y., Chiu, T., & Hu, C.-C. (2019) · RSC Advances · doi:10.1039/c9ra00916g · Cited by 31
Wu, Z., He, D., & Cui, B. (2018) · Microchimica Acta · doi:10.1007/s00604-018-3058-1 · Cited by 30
A turn-on fluorescent probe for vitamin C based on the use of a silicon/CoOOH nanoparticle system
Lu, Q., Chen, X., Liu, D., Wu, C., Liu, M., Li, H., Zhang, Y., & Yao, S. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3181-z · Cited by 30
Quatela, A., Gilmore, A. M., Gall, K. E. S., Sandros, M. G., Csatorday, K., Siemiarczuk, A., Yang, B., & Camenen, L. (2018) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/aaa818 · Cited by 28
A green emissive carbon-dot-based sensor with diverse responsive manners for multi-mode sensing
Pan, X., Zhang, Y., Sun, X., Pan, W., & Wang, J. (2018) · The Analyst · doi:10.1039/c8an01552j · Cited by 27
Su, W. W., Liu, B., Lu, W., Xu, N., Du, G., & Tan, J. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20510 · Cited by 26
Effect of Concentration on the Photophysics of Dyes in Light‐Scattering Materials.
Rodríguez, H. B., & Román, E. S. (2013) · Photochemistry and Photobiology · doi:10.1111/php.12107 · Cited by 25
Zhang, C., Liu, M., Han, B., & Xing, X. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2009.04.029 · Cited by 24
Wu, B., Yang, M., Yin, R., & Zhang, S. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2017.04.011 · Cited by 22
Xue, D., Yu, F., Zhang, Z., & Yang, Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.101 · Cited by 22
A Generalized Model on the Effects of Nanoparticles on Fluorophore Fluorescence in Solution
Zhang, D., & Nettles, C. B. (2015) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5b00597 · Cited by 21
Panigrahi, S. K., Thakur, S., Sarathi, R., & Mishra, A. K. (2017) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2017.006592 · Cited by 20
Zeng, L., Wang, C., Wang, T., & Li, D.-L. (2016) · The Analyst · doi:10.1039/c6an00836d · Cited by 15
Wilczek-Vera, G., & Salin, E. D. (2010) · Journal of Chemical Education · doi:10.1021/ed1005129 · Cited by 13
Cited by
Porous organic polymers as a platform for sensing applications
Wang, S., Li, H., Huang, H., Cao, X., Chen, X., & Cao, D. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00059h · Cited by 363
Metal organic framework based fluorescence sensor for detection of antibiotics
Marimuthu, M., Arumugam, S. S., Sabarinathan, D., Li, H., & Chen, Q. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.08.022 · Cited by 341
Luminescence in Crystalline Organic Materials: From Molecules to Molecular Solids
Gierschner, J., Shi, J., Milián‐Medina, B., Roca‐Sanjuán, D., Varghese, S., & Park, S. (2021) · Advanced Optical Materials · doi:10.1002/adom.202002251 · Cited by 301
Zero-Dimensional Carbon Nanomaterials for Fluorescent Sensing and Imaging
Yang, Z., Xu, T., Li, H., She, M., Chen, J., Wang, Z., Zhang, S., & Li, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00186 · Cited by 300
Dual Emission: Classes, Mechanisms, and Conditions
Behera, S. K., Park, S. Y., & Gierschner, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009789 · Cited by 292
Metadata
- Authors
- Kumar Panigrahi, S., & Kumar Mishra, A.
- Venue
- Journal of Photochemistry and Photobiology C: Photochemistry Reviews
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 41
- Pages
- 100318
- ISSN
- 1389-5567 (ISSN-L)
- OpenAlex
- W2972600456
- Cited by
- 485
- References
- 95
- FWCI
- 21.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.