Advancements in CAD/CAM technology: Options for practical implementation
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this review is to present a comprehensive review of the current published literature investigating the various methods and techniques for scanning, designing, and fabrication of CAD/CAM generated restorations along with detailing the new classifications of CAD/CAM technology. STUDY SELECTION: I performed a review of a PubMed using the following search terms "CAD/CAM, 3D printing, scanner, digital impression, and zirconia". The articles were screened for further relevant investigations. The search was limited to articles written in English, published from 2001 to 2015. In addition, a manual search was also conducted through articles and reference lists retrieved from the electronic search and peer-reviewed journals. RESULTS: CAD/CAM technology has advantages including digital impressions and models, and use of virtual articulators. However, the implementation of this technology is still considered expensive and requires highly trained personnel. Currently, the design software has more applications including complete dentures and removable partial denture frameworks. The accuracy of restoration fabrication can be best attained with 5 axes milling units. The 3D printing technology has been incorporated into dentistry, but does not include ceramics and is limited to polymers. In the future, optical impressions will be replaced with ultrasound impressions using ultrasonic waves, which have the capability to penetrate the gingiva non-invasively without retraction cords and not be affected by fluids. CONCLUSION: The coming trend for most practitioners will be the use of an acquisition camera attached to a computer with the appropriate software and the capability of forwarding the image to the laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
Ender, A., & Mehl, A. (2013) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(13)60028-1 · Cited by 622
Intraoral Digital Impression Technique: A Review
Su, T.-S., & Jian, S. (2014) · Journal of Prosthodontics · doi:10.1111/jopr.12218 · Cited by 492
Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams
Abduo, J., Lyons, K., & Bennamoun, M. (2014) · International Journal of Dentistry · doi:10.1155/2014/783948 · Cited by 424
Bidra, A. S., Taylor, T. D., & Agar, J. R. (2013) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(13)60318-2 · Cited by 418
Örtorp, A., Jönsson, D., Mouhsen, A., & von Steyern, P. V. (2010) · Dental Materials · doi:10.1016/j.dental.2010.11.015 · Cited by 387
Rapid Prototyping Technologies and their Applications in Prosthodontics, a Review of Literature.
Torabi, K., Farjood, E., & Hamedani, S. (2015) · PubMed Central · Cited by 343
Direct Inkjet Printing of Dental Prostheses Made of Zirconia
Ebert, J., Özkol, E., Zeichner, A., Uibel, K., Weiss, Ö., Koops, U., Telle, R., & Fischer, H. (2009) · Journal of Dental Research · doi:10.1177/0022034509339988 · Cited by 281
Mously, H. A., Finkelman, M., Zandparsa, R., & Hirayama, H. (2014) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.03.017 · Cited by 230
A comparison of plaster, digital and reconstructed study model accuracy
Keating, A. P., Knox, J., Bibb, R., & Zhurov, A. I. (2008) · Journal of Orthodontics · doi:10.1179/146531207225022626 · Cited by 225
CAD/CAM Complete Dentures: A Review of Two Commercial Fabrication Systems
Kattadiyil, M. T., Goodacre, C. J., & Baba, N. Z. (2013) · Journal of the California Dental Association · doi:10.1080/19424396.2013.12222317 · Cited by 197
Anadioti, E., Aquilino, S. A., Gratton, D. G., Holloway, J. A., Denry, I., Thomas, G. W., & Qian, F. (2014) · Journal of Prosthodontics · doi:10.1111/jopr.12180 · Cited by 183
Ahrberg, D., Lauer, H. C., Ahrberg, M., & Weigl, P. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-015-1504-6 · Cited by 163
Patzelt, S. B. M., Bishti, S., Stampf, S., & Att, W. (2014) · The Journal of the American Dental Association · doi:10.14219/jada.2014.87 · Cited by 156
Pradíes, G., Zarauz, C., Valverde, A., Ferreiroa, A., & Martínez‐Rus, F. (2014) · Journal of Dentistry · doi:10.1016/j.jdent.2014.12.007 · Cited by 155
Tooth preparation for full-coverage restorations—a literature review
Podhorsky, A., Rehmann, P., & Wöstmann, B. (2015) · Clinical Oral Investigations · doi:10.1007/s00784-015-1439-y · Cited by 122
Diagnostic accuracy of impression-free digital models
Akyalçın, S., Cozad, B. E., English, J. D., Colville, C. D., & Laman, S. (2013) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.04.024 · Cited by 107
CEREC CAD/CAM Chairside System.
Sannino, G., Germano, F., Arcuri, L., Bigelli, E., Arcuri, C., & Barlattani, A. (2014) · PubMed · doi:10.11138/orl/2014.7.3.057 · Cited by 94
The Role of Virtual Articulator in Prosthetic and Restorative Dentistry
Koralakunte, P. R. (2014) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2014/8929.4648 · Cited by 69
Direct transfer of the position of digitized casts to a virtual articulator
Solaberrieta, E., Mínguez, R., Barrenetxea, L., & Etxaniz, O. (2013) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(13)60330-3 · Cited by 67
Kim, J., Kim, K.-B., Kim, W., Kim, J., & Kim, H. (2014) · The Korean Journal of Orthodontics · doi:10.4041/kjod.2014.44.2.69 · Cited by 46
Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns
Alghazzawi, T. F. F., Al-Samadani, K. H., Lemons, J. E., Liu, P., Essig, M. E., Bartolucci, A. A., & Janowski, G. M. (2015) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2014.10.006 · Cited by 38
Self-citationHigh-Frequency Ultrasound as an Option for Scanning of Prepared Teeth: An in Vitro Study
Pekam, F. C., Marotti, J., Wolfart, S., Tinschert, J., Radermacher, K., & Heger, S. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.08.023 · Cited by 24
Cited by
Revilla-León, M., Jiang, P., Sadeghpour, M., Piedra-Cascón, W., Zandinejad, A., Özcan, M., & Krishnamurthy, V. R. (2020) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2019.06.003 · Cited by 318
Goujat, A., Abouelleil, H., Colon, P., Jeannin, C., Pradelle, N., Seux, D., & Grosgogeat, B. (2019) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.06.006 · Cited by 208
“The rotary instrument size and shape of the milling unit can influence the adaptation of a restoration.(2,4,25,61,67,70,77) Overmilling of any surface details less than the diameter of the milling rotary instrument will result in a less accurate restoration,(2,70) especially at the line angles of the preparation.”
BackgroundEndodontic applications of 3D printing
Anderson, J., Wealleans, J., & Ray, J. (2018) · International Endodontic Journal · doi:10.1111/iej.12917 · Cited by 207
Additive manufacturing of dental polymers: An overview on processes, materials and applications
JOCKUSCH, J., & ÖZCAN, M. (2020) · Dental Materials Journal · doi:10.4012/dmj.2019-123 · Cited by 169
Sim, J.-Y., Jang, Y., Kim, W.-C., Kim, H.-Y., Lee, D.-H., & Kim, J.-H. (2019) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2018.02.002 · Cited by 168
Metadata
- Authors
- Alghazzawi, T. F.
- Venue
- Journal of Prosthodontic Research
- Publisher
- Japan Prosthodontic Society
- Published
- 2016-04
- Volume
- 60
- Issue
- 2
- Pages
- 72-84
- ISSN
- 1883-1958 (ISSN-L)
- OpenAlex
- W2290108649
- Cited by
- 637
- References
- 23
- FWCI
- 53.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.