Combining low- and high-energy tandem mass spectra for optimized peptide quantification with isobaric tags
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Isobaric tagging, via TMT or iTRAQ, is widely used in quantitative proteomics. To date, tandem mass spectrometric analysis of isobarically-labeled peptides with hybrid ion trap-orbitrap (LTQ-OT) instruments has been mainly carried out with higher-energy C-trap dissociation (HCD) or pulsed q dissociation (PQD). HCD provides good fragmentation of the reporter-ions, but peptide sequence-ion recovery is generally poor compared to collision-induced dissociation (CID). Herein, we describe an approach where CID and HCD spectra are combined. The approach ensures efficiently both identification and relative quantification of proteins. Tandem mass tags (TMTs) were used to label digests of human plasma and LC-MS/MS was performed with an LTQ-OT instrument. Different HCD collision energies were tested. The benefits to use CID and HCD with respect to HCD alone were demonstrated in terms of number of identifications, subsequent number of quantifiable proteins, and quantification accuracy. A program was developed to merge the peptide sequence-ion m/z range from CID spectra and the reporter-ion m/z range from HCD spectra, and alternatively to separate both spectral data into different files. As parallel CID in the LTQ almost doesn't affect the analysis duty cycle, the procedure should become a standard for quantitative analyses of proteins with isobaric tagging using LTQ-OT instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 2×
“Typically, the label can be introduced during cell growth [1–3] or during the sample preparation at the protein level (as, for example, ICAT [4]) or at the peptide”
BackgroundQuantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 2×
“[6] RossPL,HuangYN,Marchese JN,WilliamsonB,ParkerK,Hattan S, et al.”
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Cited by
Isobaric Labeling-Based Relative Quantification in Shotgun Proteomics
Rauniyar, N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500880b · Cited by 596
An insight into iTRAQ: where do we stand now?
Evans, C., Noirel, J., Ow, S. Y., Salim, M., Pereira-Medrano, A. G., Couto, N., Pandhal, J., Smith, D., Pham, T. K., Karunakaran, E., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5918-6 · Cited by 300
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Thompson, A., Wölmer, N., Koncarevic, S., Selzer, S., Böhm, G., Legner, H., Schmid, P., Kienle, S., Penning, P., Höhle, C., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04474 · Cited by 186
Wang, H., Alvarez, S., & Hicks, L. M. (2012) · Journal of Proteome Research · doi:10.1021/pr2008225 · Cited by 142
Metadata
- Authors
- Dayon, L., Pasquarello, C., Hoogland, C., Sanchez, J.-C., & Scherl, A.
- Venue
- Journal of Proteomics
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 73
- Issue
- 4
- Pages
- 769-777
- ISSN
- 1874-3919 (ISSN-L)
- OpenAlex
- W2065110399
- Cited by
- 104
- References
- 4
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.