On-column trypsin digestion coupled with LC-MS/MS for quantification of apolipoproteins
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Apolipoproteins measured in plasma or serum are potential biomarkers for assessing metabolic irregularities that are associated with the development of cardiovascular disease (CVD). LC-MS/MS allows quantitative measurement of multiple apolipoproteins in the same sample run. However, the accuracy and precision of the LC-MS/MS measurement depends on the reproducibility of the enzymatic protein digestion step. With the application of an immobilized enzyme reactor (IMER), the reproducibility of the trypsin digestion can be controlled with high precision via flow rate, column volume and temperature. In this report, we demonstrate the application of an integrated IMER-LC-MS/MS platform for the simultaneous quantitative analysis of eight apolipoproteins. Using a dilution series of a characterized serum pool as calibrator, the method was validated by repeated analysis of pooled sera and individual serum samples with a wide range of lipid profiles, all showing intra-assay CV < 4.4% and inter-assay CV < 8%. In addition, the method was compared with traditional homogeneous digestion coupled LC-MS/MS for the quantification of apoA-I and apoB-100. Applied in large scale human population studies, this method can serve the translation of a wider panel of apolipoprotein biomarkers from research to clinical application. Significance: Currently, the translation of apolipoprotein biomarkers to clinical application is impaired because of the high cost of large cohort studies using traditional single-analyte immunoassays. The application of on-line tryptic digestion coupled with LC-MS/MS analysis is an effective way to address this problem. In this work we demonstrate a high throughput, multiplexed, automated proteomics workflow for the simultaneous analysis of multiple proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marcovina, S. M., Albers, J. J., Henderson, L. O., & Hannon, W. H. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.5.773 · Cited by 342
Apolipoprotein E isoforms and lipoprotein metabolism
Phillips, M. C. (2014) · IUBMB Life · doi:10.1002/iub.1314 · Cited by 328
Topology of human apolipoprotein E3 uniquely regulates its diverse biological functions
Chen, J., Li, Q., & Wang, J. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1106420108 · Cited by 283
Marcovina, S. M., Albers, J. J., Kennedy, H., Mei, J. V., Henderson, L. O., & Hannon, W. H. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.4.586 · Cited by 243
Agger, S. A., Marney, L. C., & Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.152264 · Cited by 143
Hoofnagle, A. N., Becker, J. O., Oda, M. N., Cavigiolio, G., Mayer, P., & Vaisar, T. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.173856 · Cited by 140
Kay, R. G., Gregory, B., Grace, P. B., & Pleasance, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3130 · Cited by 119
Chunyu, Z., Christina, K., Katsunori, I., & Sacks, F. M. (2007) · Journal of Lipid Research · doi:10.1194/jlr.p600011-jlr200 · Cited by 95
Lassman, M. E., McLaughlin, T. M., Somers, E. P., Stefanni, A. C., Chen, Z., Murphy, B. A., Bierilo, K. K., Flattery, A. M., Wong, K. K., Castro‐Perez, J. M., et al. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5296 · Cited by 51
Quantifying Protein Measurands by Peptide Measurements: Where Do Errors Arise?
van den Broek, I., Romijn, F. P. H. T. M., Smit, N. P. M., van der Laarse, A., Drijfhout, J. W., van der Burgt, Y. E. M., & Cobbaert, C. M. (2015) · Journal of Proteome Research · doi:10.1021/pr5011179 · Cited by 49
Cited by
Neubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109
van den Broek, I., Fu, Q., Kushon, S., Kowalski, M. P., Millis, K., Percy, A., Holewinski, R. J., Venkatraman, V., & Van Eyk, J. E. (2017) · Clinical Mass Spectrometry · doi:10.1016/j.clinms.2017.08.004 · Cited by 62
Graf, T., Heinrich, K., Grunert, I., Wegele, H., Haberger, M., Bulau, P., & Leiss, M. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113251 · Cited by 46
Delatour, V., Clouet-Foraison, N., Gaie-Levrel, F., Marcovina, S. M., Hoofnagle, A. N., Kuklenyik, Z., Caulfield, M. P., Otvos, J. D., Krauss, R. M., Kulkarni, K. R., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.288746 · Cited by 39
Self-citationApolipoprotein profiling as a personalized approach to the diagnosis and treatment of dyslipidaemia
Renee Ruhaak, L., van der Laarse, A., & Cobbaert, C. M. (2019) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563219827620 · Cited by 38
Clouet-Foraison, N., Gaie-Levrel, F., Gillery, P., & Delatour, V. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0091 · Cited by 30
Process analytics 4.0: A paradigm shift in rapid analytics for biologics development
Wasalathanthri, D. P., Shah, R., Ding, J., Leone, A., & Li, Z. J. (2021) · Biotechnology Progress · doi:10.1002/btpr.3177 · Cited by 17
Metadata
- Authors
- Toth, C. A., Kuklenyik, Z., Jones, J. I., Parks, B. A., Gardner, M. S., Schieltz, D. M., Rees, J. C., Andrews, M. L., McWilliams, L. G., Pirkle, J. L., & Barr, J. R.
- Venue
- Journal of Proteomics
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 150
- Pages
- 258-267
- ISSN
- 1874-3919 (ISSN-L)
- OpenAlex
- W2523568958
- Cited by
- 55
- References
- 13
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.