CoChat

Bioengineered self-seeding heart valves

Open access
Jordan, James E., Williams, J. Koudy, Lee, Sang-Jin, Raghavan, Devanathan, Atala, Anthony, Yoo, James J. · 2012 · The Journal of Thoracic and Cardiovascular Surgery
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE Mechanical and biological prostheses are used to replace damaged heart valves but are associated with significant morbidities. Although there is increased interest in bioengineering cell-seeded heart valve scaffolds, it is a time-consuming and technically difficult process. The goal of this project was to engineer self-seeding heart valves that mature quickly in vivo and have a shorter preparation time. METHODS Porcine pulmonary valves were decellularized using detergent methods and then either (1) left untreated (unconjugated, n = 6), (2) reseeded with autologous endothelial progenitor cell-derived endothelial cells (cell-seeded, n = 4), or (3) conjugated with CD133 antibodies (conjugated, n = 8). The valve constructs were transplanted into the pulmonary position of sheep using standard surgical techniques. After 1 or 3 months, the implants were removed and assessed for cell and matrix content as well as biomechanical properties. RESULTS Endothelial cells expressing von Willebrand factor lined the entire length of both ventricular and arterial surfaces of conjugated valves by 1 month after implantation. Interstitial cell and structural protein content of conjugated valves increased from 1 month to 3 months with interstitial expression of metalloproteinase-9 and new collagen formation. In contrast, there were few endothelial or interstitial cells associated with unconjugated, or cell-seeded valves at any time point. No calcification or thrombi were noted on any of the valves. Young's modulus and tensile strength was greater in the conjugated valves versus unconjugated or cell-seeded valves. CONCLUSIONS Results indicate that tissue-engineered heart valve replacement constructs can be made quickly and therefore may be a clinically relevant option for patients needing heart valve surgery in a timely fashion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jtcvs.2011.10.005

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Jordan, J. E., Williams, J. K., Lee, S.-J., Raghavan, D., Atala, A., & Yoo, J. J.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
2012-01
Volume
143
Issue
1
Pages
201-208
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2004910407
Cited by
80
References
2
FWCI
7.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.