CoChat

Utilization, patency, and complications associated with vascular access for hemodialysis in the United States

Open access
Arhuidese, Isibor J., Orandi, Babak J., Nejim, Besma, Malas, Mahmoud · 2018 · Journal of Vascular Surgery
Cited by 196

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Background: This study examines the utilization and outcomes of vascular access for long‐term hemodialysis in the United States and describes the impact of temporizing catheter use on outcomes. We aimed to evaluate the prevalence, patency, and associated patient survival for pre‐emptively placed autogenous fistulas and prosthetic grafts; for autogenous fistulas and prosthetic grafts placed after a temporizing catheter; and for hemodialysis catheters that remained in use. Methods: We performed a retrospective study of all patients who initiated hemodialysis in the United States during a 5‐year period (2007‐2011). The United States Renal Data System‐Medicare matched national database was used to compare outcomes after pre‐emptive autogenous fistulas, preemptive prosthetic grafts, autogenous fistula after temporizing catheter, prosthetic graft after temporizing catheter, and persistent catheter use. Outcomes were primary patency, primary assisted patency, secondary patency, maturation, catheter‐free dialysis, severe access infection, and mortality. Results: There were 73,884 (16%) patients who initiated hemodialysis with autogenous fistula, 16,533 (3%) who initiated hemodialysis with prosthetic grafts, 106,797 (22%) who temporized with hemodialysis catheter prior to autogenous fistula use, 32,890 (7%) who temporized with catheter prior to prosthetic graft use, and 246,822 (52%) patients who remained on the catheter. Maturation rate and median time to maturation were 79% vs 84% and 47 days vs 29 days for pre‐emptively placed autogenous fistulas vs prosthetic grafts. Primary patency (adjusted hazard ratio [aHR], 1.26; 95% confidence interval [CI], 1.25‐1.28; P < .001) and primary assisted patency (aHR, 1.36; 95% CI, 1.35‐1.38; P < .001) were significantly higher for autogenous fistula compared with prosthetic grafts. Secondary patency was higher for autogenous fistulas beyond 2 months (aHR, 1.36; 95% CI, 1.32‐1.40; P < .001). Severe infection (aHR, 9.6; 95% CI, 8.86‐10.36; P < .001) and mortality (aHR, 1.29; 95% CI, 1.27‐1.31; P < .001) were higher for prosthetic grafts compared with autogenous fistulas. Temporizing with a catheter was associated with a 51% increase in mortality (aHR, 1.51; 95% CI, 1.48‐1.53; P < .001), 69% decrease in primary patency (aHR, 0.31; 95% CI, 0.31‐0.32; P < .001), and 130% increase in severe infection (aHR, 2.3; 95% CI, 2.2‐2.5; P < .001) compared to initiation with autogenous fistulas or prosthetic grafts. Mortality was 2.2 times higher for patients who remained on catheters compared to those who initiated hemodialysis with autogenous fistulas (aHR, 2.25; 95% CI, 2.21‐2.28; P < .001). Conclusions: Temporizing catheter use was associated with higher mortality, higher infection, and lower patency, thus undermining the highly prevalent approach of electively using catheters as a bridge to permanent access. Autogenous fistulas are associated with longer time to catheter‐free dialysis but better patency, lower infection risk, and lower mortality compared with prosthetic grafts in the general population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jvs.2018.01.049

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 196

Metadata

Authors
Arhuidese, I. J., Orandi, B. J., Nejim, B., & Malas, M.
Venue
Journal of Vascular Surgery
Publisher
Elsevier BV
Published
2018-10
Volume
68
Issue
4
Pages
1166-1174
ISSN
0741-5214 (ISSN-L)
OpenAlex
W2889817815
Cited by
196
References
21
FWCI
23.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.