A new way of assessing arm function in activity using kinematic Exposure Variation Analysis and portable inertial sensors—A validity study
Abstract
Portable motion systems based on inertial motion sensors are promising methods, with the advantage compared to optoelectronic cameras of not being confined to a laboratory setting. A challenge is to develop relevant outcome measures for clinical use. The aim of this study was to characterize elbow and shoulder motion during functional tasks, using portable motion sensors and a modified Exposure Variation Analysis (EVA) and evaluate system accuracy with optoelectronic cameras. Ten healthy volunteers and one participant with sequel after stroke performed standardised functional arm tasks. Motion was registered simultaneously with a custom developed motion sensor system, including gyroscopes and accelerometers, and an optoelectronic camera system. The EVA was applied on elbow and shoulder joints, and angular and angular velocity EVA plots was calculated. The EVA showed characteristic patterns for each arm task in the healthy controls and a distinct difference between the affected and unaffected arm in the participant with sequel after stroke. The accuracy of the portable system was high with a systematic error ranging between -1.2° and 2.0°. The error was direction specific due to a drift component along the gravity vector. Portable motion sensor systems have high potential as clinical tools for evaluation of arm function. EVA effectively illustrates joint angle and joint angle velocity patterns that may capture deficiencies in arm function and movement quality. Next step will be to manage system drift by including magnetometers, to further develop clinically relevant outcome variables and apply this for relevant patient groups.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Shoulder heterogeneity of results (RMSE 0.2-64.5° and r 0.69-1.00) and movements made it difficult to conclude validity.
“Despite a larger number of studies published for this joint, heterogeneity of results (RMSE between 0.2 and 64.5° and r from 0.69 to 1.00) and movements performed made it difficult to conclude the validity of using M/IMU systems for movement at this joint [31,32,33,34,35,37,38,39,42,43,44,45].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [31]
Elbow RMSE and correlation coefficient results ranged from 0.2 to 30.6° and 0.68 to 0.99, showing good to excellent validity.
“RMSE and correlation coefficient results range from 0.2 to 30.6° and 0.68 to 0.99, respectively, showing good to excellent validity [28,31,32,33,34,35,37,39,43,45].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [31]
Cites
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819 · see citing works
The Design and Analysis of Clinical Experiments.
Hills, M., & Fleiss, J. L. (1987) · Journal of the Royal Statistical Society Series A (General) · doi:10.2307/2982050 · Cited by 3,261 · see citing works
Muro, A., García-Zapirain, B., & Zorrilla, A. M. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,181 · see citing works
Platz, T., Pinkowski, C., van Wijck, F., Kim, I.-H., Bella, P. D., & Johnson, G. R. (2005) · Clinical Rehabilitation · doi:10.1191/0269215505cr832oa · Cited by 892 · see citing works
The gait deviation index: A new comprehensive index of gait pathology
Schwartz, M. H., & Rozumalski, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.05.001 · Cited by 770 · see citing works
Cole, G. K., Nigg, B. M., Ronsky, J. L., & Yeadon, M. R. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895496 · Cited by 471 · see citing works
Sturm, J. W., Donnan, G. A., Dewey, H. M., Macdonell, R. A. L., Gilligan, A. K., Srikanth, V. K., & Thrift, A. G. (2004) · Stroke · doi:10.1161/01.str.0000141977.18520.3b · Cited by 450 · see citing works
Murphy, M. A., Willén, C., & Sunnerhagen, K. S. (2010) · Neurorehabilitation and neural repair · doi:10.1177/1545968310370748 · Cited by 364 · see citing works
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aïssaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 315 · see citing works
Functional calibration procedure for 3D knee joint angle description using inertial sensors
Favre, J., Aïssaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.025 · Cited by 302 · see citing works
Use of multiple wearable inertial sensors in upper limb motion tracking
Zhou, H., Stone, T., Hu, H., & Harris, N. D. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.010 · Cited by 231 · see citing works
Quantifying variation in physical load using exposure-vs-time data
Mathiassen, S. E., & Winkel, J. (1991) · Ergonomics · doi:10.1080/00140139108964889 · Cited by 204 · see citing works
Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurement
Favre, J., Jolles, B. M., Siegrist, O., & Aminian, K. (2006) · Electronics Letters · doi:10.1049/el:20060124 · Cited by 159 · see citing works
Biomechanics of reaching: clinical implications for individuals with acquired brain injury
McCrea, P. H., Eng, J. J., & Hodgson, A. J. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110115393 · Cited by 158 · see citing works
Bourke, A. K., O’Donovan, K. J., & OLaighin, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.12.003 · Cited by 143 · see citing works
Woltring, H. J., Long, K., Osterbauer, P. J., & Fuhr, A. W. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90192-9 · Cited by 133 · see citing works
Assessment of Arm Activity Using Triaxial Accelerometry in Patients With a Stroke
van der Pas, S. C., Verbunt, J. A., Breukelaar, D. E., van Woerden, R., & Seelen, H. A. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.02.021 · Cited by 131 · see citing works
Gait analysis using gravitational acceleration measured by wearable sensors
Takeda, R., Tadano, S., Todoh, M., Morikawa, M., Nakayasu, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.027 · Cited by 128 · see citing works
Feasibility of using inertial sensors to assess human movement
Saber-Sheikh, K., Bryant, E. C., Glazzard, C., Hamel, A., & Lee, R. (2009) · Manual Therapy · doi:10.1016/j.math.2009.05.009 · Cited by 128 · see citing works
Validation of a New Biomechanical Model to Measure Muscle Tone in Spastic Muscles
Lindberg, P. G., Gäverth, J., Islam, M., Fagergren, A., Borg, J., & Forssberg, H. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968311403494 · Cited by 128 · see citing works
Gait Analysis Alters Decision-Making in Cerebral Palsy
Cook, R. E., Schneider, I., Hazlewood, M. E., Hillman, S. J., & Robb, J. (2003) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200305000-00004 · Cited by 126 · see citing works
Upper-Limb Spasticity During the First Year After Stroke
Opheim, A. I., Danielsson, A., Murphy, M. A., Persson, H., & Sunnerhagen, K. S. (2014) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000157 · Cited by 125 · see citing works
Voluntary movement at the elbow in spastic hemiparesis
Fellows, S. J., Kaus, C., & Thilmann, A. F. (1994) · Annals of Neurology · doi:10.1002/ana.410360311 · Cited by 94 · see citing works
Ha, T. H., Saber-Sheikh, K., Moore, A. P., & Jones, M. P. (2012) · Manual Therapy · doi:10.1016/j.math.2012.04.003 · Cited by 81 · see citing works
Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?
Theobald, P. S., Jones, M. D., & Williams, J. M. (2011) · Manual Therapy · doi:10.1016/j.math.2011.06.007 · Cited by 74 · see citing works
Automated measurement of proprioception following stroke
Leibowitz, N., Levy, N., Weingarten, S., Grinberg, Y., Karniel, A., Sacher, Y., Serfaty, C., & Soroker, N. (2008) · Disability and Rehabilitation · doi:10.1080/09638280701640145 · Cited by 65 · see citing works
Liu, K., INOUE, Y., SHIBATA, K., & Enguo, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089454 · Cited by 58 · see citing works
Riad, J., Coleman, S. C., Lundh, D., & Broström, E. W. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.09.022 · Cited by 57 · see citing works
DeJong, S. L., Schaefer, S. Y., & Lang, C. E. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968311425926 · Cited by 55 · see citing works
Ishigaki, N., Kimura, T., Usui, Y., Aoki, K., Narita, N., Shimizu, M., Hara, K., Ogihara, N., Nakamura, K., Kato, H., et al. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.016 · Cited by 47 · see citing works
Application of wearable inertial sensors in stroke rehabilitation
Zhou, H., Hu, H., & Harris, N. D. (2005) · doi:10.1109/iembs.2005.1616072 · Cited by 46 · see citing works
Straker, L. M., Campbell, A., Mathiassen, S. E., Abbott, R. A., Parry, S. P., & Davey, P. C. (2014) · Journal of Physical Activity and Health · doi:10.1123/jpah.2012-0105 · Cited by 38 · see citing works
van Kordelaar, J., van Wegen, E. E. H., Nijland, R. H. M., de Groot, J. H., Meskers, C. G. M., Harlaar, J., & Kwakkel, G. (2011) · Physical Therapy · doi:10.2522/ptj.20100341 · Cited by 37 · see citing works
Öhberg, F., Lundström, R., & Grip, H. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/8/085703 · Cited by 31 · see citing works
Self-citationSeitz, R. J., Hildebold, T., & Simeria, K. (2010) · Journal of Neurology · doi:10.1007/s00415-010-5778-y · Cited by 30 · see citing works
Motor impairment evaluation for upper limb in stroke patients on the basis of a microsensor
Huang, S., Luo, C., Ye, S., Liu, F., Xie, B., Wang, C., Yang, L., Huang, Z., & Wu, J. (2012) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0b013e328353053a · Cited by 28 · see citing works
Objective Assessment of shoulder mobility with a new 3D gyroscope - a validation study
El-Zayat, B. F., Efe, T., Heidrich, A., Wolf, U., Timmesfeld, N., Heyse, T. J., Lakemeier, S., Fuchs‐Winkelmann, S., & Schofer, M. D. (2011) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-12-168 · Cited by 22 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Wearable systems for shoulder kinematics assessment: a systematic review
Carnevale, A., Longo, U. G., Schena, E., Massaroni, C., Presti, D. L., Berton, A., Candela, V., & Denaro, V. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2930-4 · Cited by 129 · see citing works
Determining anatomical frames via inertial motion capture: A survey of methods
Vitali, R. V., & Perkins, N. C. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109832 · Cited by 100 · see citing works
Conversion of Upper-Limb Inertial Measurement Unit Data to Joint Angles: A Systematic Review
Fang, Z., Woodford, S. C., Senanayake, D., & Ackland, D. C. (2023) · Sensors · doi:10.3390/s23146535 · Cited by 73 · see citing works
Poitras, I., Bielmann, M., Campeau‐Lecours, A., Mercier, C., Bouyer, L. J., & Roy, J. (2019) · Sensors · doi:10.3390/s19081885 · Cited by 65 · see citing works
The importance of inertial measurement unit placement in assessing upper limb motion
Höglund, G., Grip, H., & Öhberg, F. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.03.010 · Cited by 59 · see citing works
Self-citationCable-driven lower limb rehabilitation robot
Barbosa, A. M., Carvalho, J. C. M., & Gonçalves, R. S. (2018) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-018-1172-y · Cited by 48 · see citing works
Park, E., Lee, K., Han, T., & Nam, H. S. (2020) · Journal of Medical Internet Research · doi:10.2196/20641 · Cited by 42 · see citing works
Baets, L. D., van der Straaten, R., Matheve, T., & Timmermans, A. A. A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.025 · Cited by 41 · see citing works
Validity and reliability of inertial sensors for elbow and wrist range of motion assessment
Costa, V., Ramírez, O. E. M., Otero, A., Muñoz‐García, D., Uribarri, S., & Raya, R. (2020) · PeerJ · doi:10.7717/peerj.9687 · Cited by 37 · see citing works
Aasa, U., Bengtsson, V., Berglund, L., & Öhberg, F. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1675751 · Cited by 31 · see citing works
Self-citationWu, Y., Tao, K., Chen, Q., Tian, Y., & Sun, L. (2022) · Sensors · doi:10.3390/s22186954 · Cited by 27 · see citing works
Torriani‐Pasin, C., Demers, M., Polese, J. C., Bishop, L., Wade, E., Hempel, S., & Winstein, C. J. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1953623 · Cited by 21 · see citing works
Severin, A. C., Burkett, B. J., McKean, M. R., Wiegand, A. N., & Sayers, M. G. L. (2017) · PLoS ONE · doi:10.1371/journal.pone.0182320 · Cited by 19 · see citing works
Li, J., Qiu, F., Gan, L., & Chou, L. (2024) · Wearable Technologies · doi:10.1017/wtc.2024.6 · Cited by 18 · see citing works
Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
Öhberg, F., Bäcklund, T., Sundström, N., & Grip, H. (2019) · Sensors · doi:10.3390/s19051241 · Cited by 18 · see citing works
Self-citationRojo, A., Cortina, J., Sánchez, C., Urendes, E. J., García-Carmona, R., & Raya, R. (2022) · Virtual Reality · doi:10.1007/s10055-022-00660-4 · Cited by 17 · see citing works
Towards the implementation of natural prosthetic elbow motion using upper limb joint coordination
Mérad, M., Roby-Brami, A., & Jarrassé, N. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523729 · Cited by 16 · see citing works
The Effect of Triangular Fibrocartilage Complex Tear on Wrist Proprioception
Park, J. H., Kim, D., Park, H. S., Jung, I., Youn, I., & Park, J. W. (2018) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2018.01.022 · Cited by 16 · see citing works
Baets, L. D., Vanbrabant, S., Dierickx, C., van der Straaten, R., & Timmermans, A. A. A. (2020) · Sensors · doi:10.3390/s20030876 · Cited by 16 · see citing works
Grip, H., Källströmer, A., & Öhberg, F. (2022) · Sensors · doi:10.3390/s22239557 · Cited by 9 · see citing works
Self-citationÖhberg, F., Vänn, M., Jonzén, K., Edström, U., & Sundström, N. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.10.005 · Cited by 9 · see citing works
Self-citationA Comparative Analysis of IMUs and Optical Systems in Layup Shot Biomechanics
Alkhalaf, N., Pain, M. T. G., & Hiley, M. J. (2025) · Applied Sciences · doi:10.3390/app15073847 · Cited by 6 · see citing works
DataSpoon: Validation of an Instrumented Spoon for Assessment of Self-Feeding
Krasovsky, T., Weiss, P. L., Zuckerman, O., Bar, A., Keren-Capelovitch, T., & Friedman, J. (2020) · Sensors · doi:10.3390/s20072114 · Cited by 6 · see citing works
Skvortsov, D. V., Николаевич, К. С., Ivanova, G. Е., Lobov, A. N., & Zhuravleva, A. N. (2017) · S S Korsakov Journal of Neurology and Psychiatry · doi:10.17116/jnevro201711712294-101 · Cited by 3 · see citing works
Reaching to inhibit a prepotent response: A wearable 3-axis accelerometer kinematic analysis
Angeli, A., Valori, I., Farroni, T., & Marfia, G. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254514 · Cited by 3 · see citing works
Berglund, L., Öhberg, F., Strömbäck, E., & Papacosta, D. (2024) · International Journal of Sports Physical Therapy · doi:10.26603/001c.122637 · Cited by 1 · see citing works
Self-citationBrusaca, L. A., Barbieri, D. F., Holtermann, A., Gupta, N., & Mathiassen, S. E. (2025) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2025.2573776 · Cited by 1 · see citing works
Thakkar, P., Sharma, D., Hodakowski, A. J., Bonadiman, J. A., Westrick, J. C., & Gustafson, J. A. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2026.2626474 · Cited by 1 · see citing works
Николаевич, К. С., Skvortsov, D. V., Ivanova, G. Е., Lobov, A. N., & Zhuravleva, A. I. (2018) · Problems of Balneology Physiotherapy and Exercise Therapy · doi:10.17116/kurort201895326 · Cited by 1 · see citing works
Upper-Limb Kinematics During Feeding and Drinking
Parra-Sánchez, S., Gómez-González, J. M., Quintero-Ortega, A. I., Castellano, L. E., Mendoza‐Novelo, B., Delgado-García, J. J., Cuéllar‐Cruz, M., & Vega‐González, A. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-4086-3_155
Николаевич, К. С., Skvortsov, D. V., & Ivanova, G. Е. (2020) · Journal of Medical Imaging and Case Reports · doi:10.17756/micr.2020-043
Bäcklund, T. (2021) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Beraldo, L. M., Silva, M. G., & Candotti, C. T. (2022) · Fisioterapia e Pesquisa · doi:10.1590/1809-2950/22006029032022pt
Beraldo, L. M., Silva, M. G., & Candotti, C. T. (2022) · Fisioterapia e Pesquisa · doi:10.1590/1809-2950/22006029032022en
Salinas, S. A., Berjis, M., Grolinger, K., & Trejos, A. L. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11063202
Posterior marker set for shoulder kinematic analysis using optoelectronic systems
Sanctis, L. D., Carnevale, A., Gulotta, L. V., Kontaxis, A., Schena, E., & Longo, U. G. (2026) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2026.113279
- Authors
- Ertzgaard, P., Öhberg, F., Gerdle, B., & Grip, H.
- Affiliations
- Linköping University (SE)
- Centre for Biomedical Engineering and Physics (SE)
- Corresponding author
- Ertzgaard, Per
- Venue
- Manual Therapy
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 21
- Pages
- 241-249
- ISSN
- 1356-689X (ISSN-L)
- OpenAlex
- W1922411293
- Cited by
- 41
- References
- 37
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 9 · 2019: 5 · 2018: 3 · 2017: 4 · 2016: 2
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Manual Therapy (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- shoulder joint motion, gyroscope drift, outcome measures, movement quality
- MeSH terms
- Adult, Biomechanical Phenomena, Elbow Joint, Female, Humans, Male, Middle Aged, Movement, Shoulder Joint, Range of Motion, Articular, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review