The DOI matches its Crossref record.
Delocalizing strain in a thin metal film on a polymer substrate
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Stretchable Interconnects for Elastic Electronic Surfaces
Lacour, S. P., Jones, J., Wagner, S., Li, T., & Suo, Z. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.851502 · Cited by 621
Self-citationPlasticity in Confined Dimensions
Kraft, O., Gruber, P. A., Mönig, R., & Weygand, D. (2010) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-082908-145409 · Cited by 429
Highly stretchable and transparent nanomesh electrodes made by grain boundary lithography
Guo, C. F., Sun, T., Liu, Q., Suo, Z., & Ren, Z. (2014) · Nature Communications · doi:10.1038/ncomms4121 · Cited by 427
Self-citationMetal films on polymer substrates stretched beyond 50%
Lu, N., Wang, X., Suo, Z., & Vlassak, J. (2007) · Applied Physics Letters · doi:10.1063/1.2817234 · Cited by 410
Self-citationWalia, S., Shah, C. M., Gutruf, P., Nili, H., Chowdhury, D. R., Withayachumnankul, W., Bhaskaran, M., & Sriram, S. (2015) · Applied Physics Reviews · doi:10.1063/1.4913751 · Cited by 392
Electronic skin: architecture and components
Wagner, S., Lacour, S. P., Jones, J., Hsu, P.-H. I., Sturm, J. C., Li, T., & Suo, Z. (2004) · Physica E: Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2004.06.032 · Cited by 309
Self-citationHigh ductility of a metal film adherent on a polymer substrate
Xiang, Y., Li, T., Suo, Z., & Vlassak, J. J. (2005) · Applied Physics Letters · doi:10.1063/1.2108110 · Cited by 306
Self-citationRecent Advances in Stretchable and Transparent Electronic Materials
McCoul, D., Hu, W., Gao, M., Mehta, V., & Pei, Q. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201500407 · Cited by 293
Design and Performance of Thin Metal Film Interconnects for Skin-Like Electronic Circuits
Lacour, S. P., Jones, J., Suo, Z., & Wagner, S. (2004) · IEEE Electron Device Letters · doi:10.1109/led.2004.825190 · Cited by 260
Self-citationStretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
“Enhancing the grip of the substrate to the thin film with better dhesion essentially increases the mec anical properties due to strain delocalization [56,58,59].”
Background
Metadata
- Authors
- Li, T., Huang, Z. Y., Xi, Z. C., Lacour, S. P., Wagner, S., & Suo, Z.
- Venue
- Mechanics of Materials
- Publisher
- Elsevier BV
- Published
- 2005-02
- Volume
- 37
- Issue
- 2-3
- Pages
- 261-273
- ISSN
- 0167-6636 (ISSN-L)
- OpenAlex
- W2123935475
- Cited by
- 233
- References
- 0
- FWCI
- 16.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.