Cited by 128Neuroscience and Neural EngineeringConducting polymers and applicationsAdvanced Sensor and Energy Harvesting Materials

Stretchable Polymeric Multielectrode Array for Conformal Neural Interfacing

Open access
Guo, Liang, Ma, Mingming, Zhang, Ning, Langer, Robert, Anderson, Daniel G.·2014·Advanced Materials

Abstract

A highly stretchable neural interface of concurrent robust electrical and mechanical properties is developed with a conducting polymer film as the sole conductor for both the electrodes and the leads. This neural interface offers the benefits of conducting polymer electrodes in a demanding stretchable format, including low electrode impedance and high chargeinjection capacity, due to the large electroactive surface area of the electrode.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201304140

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Nanomaterials and conductive polymers used in implantable stimulation electrodes have higher charge injection capacity (1-15 mC cm−2) than conventional materials such as Pt (0.05-0.15 mC cm−2) and TiN (0.9 mC cm−2).

    “In the recent decade, various nanomaterials[301,345,534,535] and conductive polymers[536–538] have also made their way into implantable stimulation electrodes, which have higher charge injection capacity (1~15 mC cm−2) compared to conventional materials (Pt 0.05~0.15 mC cm−2, TiN 0.9 mC cm−2).[39]”

    From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [535]

    The charge-injection passage (labeled Abstract in our copy; page unavailable) reports 3.9 mC cm−2 for a conducting-polymer electrode and says it outperformed many common electrode materials. It does not give the claimed Pt range of 0.05–0.15 mC cm−2 or TiN value of 0.9 mC cm−2, or establish the 1–15 mC cm−2 range for nanomaterials and conductive polymers generally. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. [18]a) Lacour SP Jones JE Wagner S Li T Suo Z Proc IEEE 2005 93 1459 b) Wagner S Lacour SP Jones J Hsu PI Sturm JC Li T Suo Z Physica E 2004 25 326
  2. [25]Maghribi M Hamilton J Polla D Rose K Wilson T Krule-vitch P Proc 2nd Annu Int IEEE-EMB Special Topic Conf Microtechnologies in Medicine and Biology 2002 80
  3. [26]Lacour SP Tsay C Wagner S Yu Z Morrison B Proc 4th IEEE Sensors Conf 2005 617
  4. [29]a) Wilks SJ Richardson-Burns SM Hendricks JL Martin DC Otto KJ Front Neuroeng 2009 2 Article 7 b) Venkatraman S Hendricks J King ZA Sereno AJ Richardson-Burns S Martin D Carmena JM IEEE T Neur Sys Reh 2011 19 307 21292598

Cited by

Sorted by citations

Authors
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G.
Affiliations
  • Koch Institute for Integrative Cancer Research At MIT (US)
  • David H. Koch Institute for Integrative Cancer Research Department of Chemical Engineering Division of Health Science and Technology Institute for Medical Engineering and Science Massachusetts Institute of Technology Cambridge Massachusetts 02139 USA
Corresponding author
Anderson, Daniel G.
Venue
Advanced Materials
Publisher
Wiley
Published
2013-10-22
Volume
26
Issue
9
Pages
1427-1433
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W1986261217
Cited by
128
References
42
Citations by year
2026: 2 · 2025: 6 · 2024: 4 · 2023: 14 · 2022: 6 · 2021: 15 · 2020: 15 · 2019: 14 · 2018: 18 · 2017: 13 · 2016: 10 · 2015: 8 · 2014: 2
FWCI
3.27
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc-sa)
  • PMC
Funders
  • Armed Forces Institute of Regenerative Medicine (W81XWH-08-2-0034)
  • National Heart, Lung, and Blood Institute (HHSN268201000045C)
  • National Cancer Institute (CA151884)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
microelectrode arrays, conducting polymer electrodes, electrode impedance, charge injection capacity, electrochemically active surface area, neural recording
MeSH terms
Animals, Electric Conductivity, Electric Stimulation, Electrodes, Electrophysiology, Materials Testing, Neurons, Polymers, Pyrroles, Rats, Inbred Lew, Sciatic Nerve, Tensile Strength, Linear Models, Electric Impedance, Muscle, Skeletal, Pliability, Bridged Bicyclo Compounds, Heterocyclic, Elastomers, Rats, Elastic Modulus

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›