The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions
Abstract
CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this area has adopted isotropic assignment strategy due to its simplicity. However, bone material has been recognized as an orthotropic material. This work is aimed to investigate the effects of orthotropic material property assignment on femoral finite element model by comparing with isotropic material property assignment on the same model. There were 72 finite element models obtained from the frozen CT male dataset of visible human project. Based on the analysis results of the maximum equivalent Von Mises stress and the maximum nodal displacement, three parameters were defined to achieve this comparison. The results have shown that the differences between the two material property assignments are small under two loading conditions (double-leg standing and single-leg standing) investigated in this work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The Visible Human Male: A Technical Report
Spitzer, V., Ackerman, M. J., Scherzinger, A. L., & Whitlock, D. (1996) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1996.96236280 · Cited by 705
Wirtz, D. C., Schiffers, N., Pandorf, T., Radermacher, K., Weichert, D., & Forst, R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00069-5 · Cited by 500
Improved prediction of proximal femoral fracture load using nonlinear finite element models
Keyak, J. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00045-5 · Cited by 314
Taddei, F., Pancanti, A., & Viceconti, M. (2004) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00138-3 · Cited by 274
Keyak, J. H., & Falkinstein, Y. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00081-x · Cited by 259
Determination of orthotropic bone elastic constants using FEA and modal analysis
Taylor, W. R., Roland, E., Ploeg, H., Hertig, D., Klabunde, R., Warner, M. D., Hobatho, M. C., Rakotomanana, L., & Clift, S. E. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00022-2 · Cited by 238
A comparative study on different methods of automatic mesh generation of human femurs
Viceconti, M., Bellingeri, L., Cristofolini, L., & Toni, A. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00049-0 · Cited by 217
Cited by
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Schileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.017 · Cited by 372
Topology optimization additive manufacturing-oriented for a biomedical application
Cucinotta, F., Guglielmino, E., Longo, G., Risitano, G., Santonocito, D., & Sfravara, F. (2019) · Lecture Notes in Mechanical Engineering · doi:10.1007/978-3-030-12346-8_18 · Cited by 36
Metadata
- Authors
- Peng, L., Bai, J., Zeng, X., & Zhou, Y.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2005-08-01
- Volume
- 28
- Issue
- 3
- Pages
- 227-233
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1966388799
- Cited by
- 262
- References
- 15
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions. https://app.cochat.ai/papers/10.1016/j.medengphy.2005.06.003
- The paper
- Peng, L., Bai, J., Zeng, X., & Zhou, Y. (2006). Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2005.06.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.