Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 386

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality

MacNeil, Joshua A., Boyd, Steven K.·2007·Medical Engineering & Physics

Abstract

The introduction of three-dimensional high-resolution peripheral in vivo quantitative computed tomography (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland; voxel size 82 microm) provides a new approach to monitor micro-architectural bone changes longitudinally. The accuracy of HR-pQCT for three important determinants of bone quality, including bone mineral density (BMD), architectural measurements and bone mechanics, was determined through a comparison with micro-computed tomography (microCT) and dual energy X-ray absorptiometry (DXA). Forty measurements from 10 cadaver radii with low bone mass were scanned using the three modalities, and image registration was used for 3D data to ensure identical regions were analyzed. The areal BMD of DXA correlated well with volumetric BMD by HR-pQCT despite differences in dimensionality (R(2) = 0.69), and the correlation improved when non-dimensional bone mineral content was assessed (R(2) = 0.80). Morphological parameters measured by HR-pQCT in a standard patient analysis, including bone volume ratio, trabecular number, derived trabecular thickness, derived trabecular separation, and cortical thickness correlated well with muCT measures (R(2) = 0.59-0.96). Additionally, some non-metric parameters such as connectivity density (R(2) = 0.90) performed well. The mechanical stiffness assessed by finite element analysis of HR-pQCT images was generally higher than for microCT data due to resolution differences, and correlated well at the continuum level (R(2) = 0.73). The validation here of HR-pQCT against gold-standards microCT and DXA provides insight into the accuracy of the system, and suggests that in addition to the standard patient protocol, additional indices of bone quality including connectivity density and mechanical stiffness may be appropriate to include as part of a standard patient analysis for clinical monitoring of bone quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2006.11.002

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

See all 386

Metadata

Authors
MacNeil, J. A., & Boyd, S. K.
Venue
Medical Engineering & Physics
Published
2007-12-01
Volume
29
Issue
10
Pages
1096-1105
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2148508563
Cited by
386
References
46
FWCI
28.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. https://app.cochat.ai/papers/10.1016/j.medengphy.2006.11.002
The paper
MacNeil, J. A., & Boyd, S. K. (2007). Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2006.11.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.