The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
Abstract
The introduction of three-dimensional high-resolution peripheral in vivo quantitative computed tomography (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland; voxel size 82 microm) provides a new approach to monitor micro-architectural bone changes longitudinally. The accuracy of HR-pQCT for three important determinants of bone quality, including bone mineral density (BMD), architectural measurements and bone mechanics, was determined through a comparison with micro-computed tomography (microCT) and dual energy X-ray absorptiometry (DXA). Forty measurements from 10 cadaver radii with low bone mass were scanned using the three modalities, and image registration was used for 3D data to ensure identical regions were analyzed. The areal BMD of DXA correlated well with volumetric BMD by HR-pQCT despite differences in dimensionality (R(2) = 0.69), and the correlation improved when non-dimensional bone mineral content was assessed (R(2) = 0.80). Morphological parameters measured by HR-pQCT in a standard patient analysis, including bone volume ratio, trabecular number, derived trabecular thickness, derived trabecular separation, and cortical thickness correlated well with muCT measures (R(2) = 0.59-0.96). Additionally, some non-metric parameters such as connectivity density (R(2) = 0.90) performed well. The mechanical stiffness assessed by finite element analysis of HR-pQCT images was generally higher than for microCT data due to resolution differences, and correlated well at the continuum level (R(2) = 0.73). The validation here of HR-pQCT against gold-standards microCT and DXA provides insight into the accuracy of the system, and suggests that in addition to the standard patient protocol, additional indices of bone quality including connectivity density and mechanical stiffness may be appropriate to include as part of a standard patient analysis for clinical monitoring of bone quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Osteoporosis Prevention, Diagnosis, and Therapy
NIH Consensus Development Panel on Osteoporosis Prevention, D. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.6.785 · Cited by 5,529
Neer, R. M., Arnaud, C. D., Zanchetta, J. R., Prince, R., Gaich, G. A., Reginster, J.-Y., Hodsman, A. B., Eriksen, E. F., Ish-Shalom, S., Genant, H. K., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105103441904 · Cited by 4,602
Risk Factors for Hip Fracture in White Women
Cummings, S. R., Nevitt, M. C., Browner, W. S., Stone, K., Fox, K. M., Ensrud, K. E., Cauley, J., Black, D., & Vogt, T. M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503233321202 · Cited by 3,595
ASSESSMENT OF FRACTURE RISK AND ITS APPLICATION TO SCREENING FOR POSTMENOPAUSAL OSTEOPOROSIS
Alexeeva, L. P., Burkhardt, P., Christiansen, C., Cooper, C. C., Delmas, P. D., Johnell, O., Johnston, C. C., Kanis, J. A., Lips, P. T. A. M., Melton, L. J., et al. (1994) · Cited by 2,655
A new method for the model‐independent assessment of thickness in three‐dimensional images
Hildebrand, T., & Rüegsegger, P. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.1340694.x · Cited by 1,818
Parfitt, A. M., Mathews, C. H., Villanueva, A. R., Kleerekoper, M., Frame, B., & Rao, D. S. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111096 · Cited by 1,545
Boutroy, S., Bouxsein, M. L., Munoz, F., & Delmas, P. D. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1258 · Cited by 1,192
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Quantification of Bone Microarchitecture with the Structure Model Index
HILDEBRAND, T., & RÜEGSEGGER, P. (1997) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/01495739708936692 · Cited by 1,051
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
PET-CT image registration in the chest using free-form deformations
Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809072 · Cited by 871
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Kleerekoper, M., Villanueva, A. R., Stanciu, J., Rao, D. S., & Parfitt, A. M. (1985) · Calcified Tissue International · doi:10.1007/bf02554913 · Cited by 695
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
Odgaard, A., & Gundersen, H. J. G. (1993) · Bone · doi:10.1016/8756-3282(93)90245-6 · Cited by 680
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
Pistoia, W., van Rietbergen, B., Lochmüller, E.-M., Lill, C. A., Eckstein, F., & Rüegsegger, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00736-6 · Cited by 643
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603
Khosla, S., Riggs, B. L., Atkinson, E. J., Oberg, A. L., McDaniel, L. J., Holets, M., Peterson, J. M., & Melton, L. J. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050916 · Cited by 583
Peacock, M., Turner, C. H., Econs, M. J., & Foroud, T. (2002) · Endocrine Reviews · doi:10.1210/edrv.23.3.0464 · Cited by 468
In vivo high resolution 3D-QCT of the human forearm
Laib, A., Häuselmann, H. J., & Rüegsegger, P. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-606 · Cited by 454
Body, J.-J., Gaich, G. A., Scheele, W. H., Kulkarni, P. M., Miller, P. D., Peretz, A., Dore, R. K., Correa-Rotter, R., Papaioannou, A., Cumming, D. C., et al. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-020334 · Cited by 365
Hollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture
van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00093-0 · Cited by 263
Muller, R., Hildebrand, T., & Ruegsegger, P. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/009 · Cited by 245
Zanchetta, Jr., Bogado, C., Ferretti, J., Wang, O., Wilson, M., Sato, M., Gaich, G., Dalsky, G., & Myers, S. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.3.539 · Cited by 241
Müller, R., Hahn, M., Vogel, M., Delling, G., & Rüegsegger, P. (1996) · Bone · doi:10.1016/8756-3282(95)00489-0 · Cited by 209
THOMSEN, J. S., LAIB, A., KOLLER, B., PROHASKA, S., MOSEKILDE, L., & GOWIN, W. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01469.x · Cited by 188
Comparison of structure extraction methods for in vivo trabecular bone measurements
Laib, A., & Rüegsegger, P. (1999) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(98)00071-8 · Cited by 169
Application of homogenization theory to the study of trabecular bone mechanics
Hollister, S. J., Fyhrie, D. P., Jepsen, K. J., & Goldstein, S. A. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90308-a · Cited by 151
Impact of Spatial Resolution on the Prediction of Trabecular Architecture Parameters
Kothari, M., Keaveny, T. M., Lin, J. C., Newitt, D. C., Genant, H. K., & Majumdar, S. (1998) · Bone · doi:10.1016/s8756-3282(98)00031-3 · Cited by 144
Hodsman, A. B., Kisiel, M., Adachi, J. D., Fraher, L. J., & Watson, P. H. (2000) · Bone · doi:10.1016/s8756-3282(00)00316-1 · Cited by 134
Kinney, J. H., & Ladd, A. J. C. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.5.839 · Cited by 131
MacNeil, J. A., & Boyd, S. K. (2007) · Bone · doi:10.1016/j.bone.2007.02.029 · Cited by 122
Self-citationMechanical and Architectural Bone Adaptation in Early Stage Experimental Osteoarthritis
Boyd, S. K., Müller, R., & Zernicke, R. F. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.4.687 · Cited by 119
Self-citationLane, N. E., Thompson, J. M., Haupt, D. L., Kimmel, D. B., Modin, G., & Kinney, J. H. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.2.229 · Cited by 107
Smooth surface meshing for automated finite element model generation from 3D image data
Boyd, S. K., & Müller, R. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.03.006 · Cited by 101
Self-citationPistoia, W., van Rietbergen, B., Laib, A., & Ruegsegger, P. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1352734 · Cited by 100
Load transfer analysis of the distal radius from in-vivo high-resolution CT-imaging
Ulrich, D., van Rietbergen, B., Laib, A., & Ruegsegger, P. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00062-7 · Cited by 94
Boyd, S. K., Moser, S., Kuhn, M. H., Klinck, R. J., Krauze, P. L., Müller, R., & Gasser, J. A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9168-7 · Cited by 69
Self-citationThe Zürich Experience: One Decade of Three-Dimensional High-Resolution Computed Tomography
Müller, R. (2002) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200210000-00003 · Cited by 59
Yeni, Y. N., Christopherson, G. T., Dong, X. N., Kim, D., & Fyhrie, D. P. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835346 · Cited by 57
Formica, C., Nieves, J. W., Cosman, F., Garrett, P., & Lindsay, R. (1998) · Osteoporosis International · doi:10.1007/s001980050092 · Cited by 52
Su, R., Campbell, G. M., & Boyd, S. K. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.06.010 · Cited by 27
Self-citationInfrared imaging microscopy of bone: Illustrations from a mouse model of Fabry disease
Boskey, A. L., Goldberg, M., Kulkarni, A. B., & Gomez, S. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.019 · Cited by 24
Cited by
Assessment methods in human body composition
Lee, S. Y., & Gallagher, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e32830b5f23 · Cited by 694
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Buie, H. R., Campbell, G. M., Klinck, R. J., MacNeil, J. A., & Boyd, S. K. (2007) · Bone · doi:10.1016/j.bone.2007.07.007 · Cited by 601
Self-citationMacdonald, H. M., Nishiyama, K. K., Kang, J., Hanley, D. A., & Boyd, S. K. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.171 · Cited by 375
Self-citationNishiyama, K. K., Macdonald, H. M., Buie, H. R., Hanley, D. A., & Boyd, S. K. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091020 · Cited by 313
Self-citation
Metadata
- Authors
- MacNeil, J. A., & Boyd, S. K.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2007-12-01
- Volume
- 29
- Issue
- 10
- Pages
- 1096-1105
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2148508563
- Cited by
- 386
- References
- 46
- FWCI
- 28.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.