Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Measurement of human posture and movement is an important area of research in the bioengineering and rehabilitation fields. Various attempts have been initiated for different clinical application goals, such as diagnosis of pathological posture and movements, assessment of pre- and post-treatment efficacy and comparison of different treatment protocols. Image-based methods for measurements of human posture and movements have been developed, such as the photogrammetry, optoelectric technique and video analysis. However, it is found that these methods are complicated to set up, time-consuming to operate and could only be applied in laboratory environments. Electronic sensors and systems with advanced technology, namely accelerometer, gyroscope, flexible angular sensor, electromagnetic tracking system and sensing fabrics, have been developed and applied to solve the relevant application problems of the image-based methods. Nonetheless, other problems for using these electronic sensors emerged, including the environment influence and signal extraction difficulties. Further development of these electronic sensors and measurement methods could enhance their clinical applications in institutional as well as community levels. This article reviews the possible applications of these electronic sensors and systems, and precautions of their applications in analysis of human posture and movement. Such information would help researchers and clinicians in selecting and developing the most appropriate measurement techniques of using the electronic sensors for clinical applications of human posture and movement analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For historical and practical reasons (size, price, ease of use), conventional accelerometers tend to be the most commonly used sensors [15].”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [15]
Citations
Cites
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911 · cited 2×
“The measured acceleration of piezoresistive and capacitive accelerometers consists of two components, including a gravitational component and a component from other acceleration force (Bouten et al. 1997; Mathie et al. 2001; Westbrook 1994).”
BackgroundSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 2×
“One type of commercial gyroscope that has been considered for measuring human posture and motion analysis is shown in Figure 4 (Aminian et al. 2002; Sabatini et al. 2005).”
BackgroundMethodAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650 · cited 2×
“Sabatini et al. (2005) used the combined sensing unit affixed to the foot instep to estimate spatio-temporal gait parameters.”
MethodDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325 · cited 1×
“Thus, careful site selection and appropriate form of fixation of the sensor is very important for measurements (Mathie et al. 2001; Morris 1973).”
BackgroundRelations Between Standing Stability and Body Posture Parameters in Adolescent Idiopathic Scoliosis
Nault, M.-L., Allard, P., Hinse, S., Le Blanc, R., Caron, O., Labelle, H., & Sadeghi, H. (2002) · Spine · doi:10.1097/00007632-200209010-00018 · Cited by 285 · cited 2×
“1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al. 2003).”
BackgroundWearable sensor badge and sensor jacket for context awareness
Farringdon, J., Moore, A. J., Tilbury, N., Church, J., & Biemond, P. D. (2003) · Digest of Papers. Third International Symposium on Wearable Computers · doi:10.1109/iswc.1999.806681 · Cited by 239 · cited 1×
“It gives a linearly increasing asymptotic resistance when it is stretched, up to almost maximum stretch (Farringdon et al. 1999).”
BackgroundA description of an accelerometer-based mobility monitoring technique
Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.11.006 · Cited by 218 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
Background
Research works printed but not linked: 1
- Weissman, 1968, Anthropometric photogrammetry, Photogrammetr Engin, 34, 1134
Cited by
Comparative study on classifying human activities with miniature inertial and magnetic sensors
Altun, K., Barshan, B., & Tunçel, O. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.04.019 · Cited by 564
“A 016/j.patcog.2010.04.019 esponding author. ail address: billur@ee.bilkent.edu.tr (B. Barsha a b s t r a c t This paper provides a comparative study on the different techniques of classifying human activities that are performed using body-worn miniature inertial and magnetic sensors.”
BackgroundInfluentialSensors for daily life: A review
Javaid, M., Haleem, A., Rab, S., Pratap Singh, R., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100121 · Cited by 430
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
“Discussion of wearable-sensing technologies Advanced technologies have been developed and applied to solve the relevant application problems [27].”
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Metadata
- Authors
- Wong, W. Y., Wong, M. S., & Lo, K. H.
- Affiliations
- Hong Kong Polytechnic University (HK)
- ORCID
- Wong, Man Sang
- Venue
- Prosthetics & Orthotics International
- Published
- 2007-03
- Volume
- 31
- Issue
- 1
- Pages
- 62-75
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W2115115183
- Cited by
- 193
- References
- 59
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 10 · 2023: 10 · 2022: 8 · 2021: 15 · 2020: 12 · 2019: 8 · 2018: 17 · 2017: 10 · 2016: 11 · 2015: 13 · 2014: 10 · 2013: 12 · 2012: 6
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Prosthetics and Orthotics International (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- human motion analysis, electronic sensors, accelerometer, gyroscope, electromagnetic tracking, rehabilitation assessment, clinical application, signal extraction, environmental interference
- MeSH terms
- Biomechanical Phenomena, Biomedical Engineering, Electronics, Medical, Environment, Gait, Humans, Movement, Posture, Rehabilitation, Upper Extremity, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review. https://app.cochat.ai/papers/10.1080/03093640600983949
- The paper
- Wong, W. Y., Wong, M. S., & Lo, K. H. (2007). Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review. Prosthetics & Orthotics International. https://doi.org/10.1080/03093640600983949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.