The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Methods for gait event detection and analysis in ambulatory systems
Abstract
After stroke, hemiparesis is a common problem resulting in very individual needs for walking assistance. Often patients suffer from foot drop, i.e. inability to lift the foot from the ground during the swing phase of walking. Functional electrical stimulation is commonly used to correct foot drop. For all supporting stimulation devices, it is vital to adequately detect the gait events, which is traditionally obtained by a foot switch placed under the heel. To investigate present methods of gait analysis and detection for use in ambulatory rehabilitation systems, we carried out a meta-analysis on research studies. We found various sensors and sensor combinations capable of analyzing gait in ambulatory settings, ranging form simple force based binary switches to complex setups involving multiple inertial sensors and advanced algorithms. However additional effort is needed to minimize donning/doffing efforts, to overcome cosmetical aspects, and to implement those systems into closed loop ambulatory devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Gait Analysis: An Introduction
Whittle, M. W. (1986) · Cited by 920
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Gait Analysis — An Introduction
CONDIE, D. N. (1992) · International Journal of Rehabilitation Research · doi:10.1097/00004356-199206000-00017 · Cited by 650
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Automatic detection of gait events using kinematic data
O’Connor, C. M., Thorpe, S. K., O’Malley, M. J., & Vaughan, C. L. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.016 · Cited by 557
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Gait Analysis, Normal and Pathological Function.
Simon, S. R. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199303000-00027 · Cited by 494
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Jasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325
Corazza, S., Mündermann, L., Chaudhari, A. M., Demattio, T., Cobelli, C., & Andriacchi, T. P. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9122-8 · Cited by 325
Accelerometers in rehabilitation medicine for older adults
Culhane, K. M., O’Connor, M., Lyons, D., & Lyons, G. M. (2005) · Age and Ageing · doi:10.1093/ageing/afi192 · Cited by 302
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286
An inertial and magnetic sensor based technique for joint angle measurement
O’Donovan, K. J., Kamnik, R., O’Keeffe, D. T., & Lyons, G. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.010 · Cited by 281
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Development of a wearable sensor system for quantitative gait analysis
Liu, T., Inoue, Y., & Shibata, K. (2009) · Measurement · doi:10.1016/j.measurement.2009.02.002 · Cited by 262
A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
Miyazaki, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605434 · Cited by 194
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193
Real-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187
Application of tilt sensors in functional electrical stimulation
Dai, R., Stein, R. B., Andrews, B. J., James, K. B., & Wieler, M. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506403 · Cited by 167
Lau, H., & Tong, K. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.03.018 · Cited by 165
Real-time gait event detection for paraplegic FES walking
Skelly, M., & Chizeck, H. J. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918277 · Cited by 165
Gait event detection for FES using accelerometers and supervised machine learning
Williamson, R., & Andrews, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867873 · Cited by 164
The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking
Mansfield, A., & Lyons, G. M. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00116-4 · Cited by 160
Sensors for Use with Functional Neuromuscular Stimulation
Crago, P. E., Chizeck, H. J., Neuman, M. R., & Hambrecht, F. T. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325808 · Cited by 142
A Multicenter Trial of a Footdrop Stimulator Controlled by a Tilt Sensor
Stein, R. B., Chong, S., Everaert, D. G., Rolf, R., Thompson, A. K., Whittaker, M., Robertson, J., Fung, J., Preuss, R. A., Momose, K., et al. (2006) · Neurorehabilitation and neural repair · doi:10.1177/1545968306289292 · Cited by 135
Stair climbing detection during daily physical activity using a miniature gyroscope
Coley, B., Najafi, B., Paraschiv-Ionescu, A., & Aminian, K. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.08.008 · Cited by 131
Real-time gait assessment utilizing a new way of accelerometry
Willemsen, A., van Alste, J. A., & Boom, H. B. K. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90033-y · Cited by 130
Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system
Liu, K., Liu, T., SHIBATA, K., INOUE, Y., & Zheng, R. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.008 · Cited by 109
BIONic WalkAide for correcting foot drop
Weber, D. J., Stein, R. B., Chan, K. M., Loeb, G. E., RICHMOND, F. J. R., Rolf, R., James, K. B., & Chong, S. L. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847385 · Cited by 108
Veltink, P. H., Slycke, P., Hemssems, J., Buschman, R., Bultstra, G., & Hermens, H. J. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00041-3 · Cited by 101
Lower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92
Automatic detection of gait events: a case study using inductive learning techniques
Kirkwood, C. A., Andrews, B. J., & Mowforth, P. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90046-0 · Cited by 82
Programmed Six-Channel Electrical Stimulator for Complex Stimulation of Leg Muscles During Walking
Strojnik, P., Kralj, A. R., & Ursic, I. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326520 · Cited by 77
Human Movement: An Introductory Text
Trew, M., & Everett, T. (2005) · Medical Entomology and Zoology · Cited by 75
Detection of Spatio-Temporal Gait Parameters by Using Wearable Motion Sensors
Lee, S., Mase, K., & Kogure, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616075 · Cited by 49
The study of kinematic transients in locomotion using the integrated kinematic sensor
Wu, G., & Ladin, Z. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.536775 · Cited by 46
Sensor systems for lower limb functional electircal stimulation (FES) control
Williamson, R., & Andrews, B. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00038-2 · Cited by 42
Finite state control of functional electrical stimulation for the rehabilitation of gait
Sweeney, P. C., Lyons, G. M., & Veltink, P. H. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344765 · Cited by 36
A new method to measure foot contact
Nilsson, J. E., Stokes, V. P., & Thorstensson, A. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90017-x · Cited by 34
Automatic recognition of gait phases from accelerations of leg segments
Djuric, M. (2008) · Symposium on Neural Network Applications in Electrical Engineering · doi:10.1109/neurel.2008.4685586 · Cited by 23
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Shull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388
Activity Recognition Using a Single Accelerometer Placed at the Wrist or Ankle
MANNINI, A., INTILLE, S. S., ROSENBERGER, M., SABATINI, A. M., & HASKELL, W. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829736d6 · Cited by 383
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“[26] Review of sensor configurations and placements, and a brief review of gait detection methods Not specified Not a systematic review, gait detection methods were reviewed very briefly -”
BackgroundPorciuncula, F., Roto, A. V., Kumar, D., Davis, I., Roy, S., Walsh, C. J., & Awad, L. N. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.013 · Cited by 300
Metadata
- Authors
- Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2010-05-01
- Volume
- 32
- Issue
- 6
- Pages
- 545-552
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2030254544
- Cited by
- 350
- References
- 46
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.