Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We investigate whether pulse rate variability (PRV) extracted from finger photo-plethysmography (Pleth) waveforms can be the substitute of heart rate variability (HRV) from RR intervals of ECG signals during obstructive sleep apnea (OSA). Simultaneous measurements (ECG and Pleth) were taken from 29 healthy subjects during normal (undisturbed sleep) breathing and 22 patients with OSA during OSA events. Highly significant (p<0.01) correlations (1.0>r>0.95) were found between heart rate (HR) and pulse rate (PR). Bland-Altman plot of HR and PR shows good agreement (<5% difference). Comparison of 2 min recording epochs demonstrated significant differences (p<0.01) in time, frequency domains and complexity analysis, between normal and OSA events using PRV as well as HRV measures. Results suggest that both HRV and PRV indices could be used to distinguish OSA events from normal breathing during sleep. However, several variability measures (SDNN, RMSSD, HF power, LF/HF and sample entropy) of PR and HR were found to be significantly (p<0.01) different during OSA events. Therefore, we conclude that PRV provides accurate inter-pulse variability to measure heart rate variability under normal breathing in sleep but does not precisely reflect HRV in sleep disordered breathing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
Cited by
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
Mobile healthcare applications: system design review, critical issues and challenges
Baig, M. M., GholamHosseini, H., & Connolly, M. J. (2015) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-014-0315-4 · Cited by 234
“Various techniques were applied to collect high quality data [103, 127–132].”
MethodA review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
Akar, S. A., Kara, S., Latifoğlu, F., & Bilgiç, V. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9580-8 · Cited by 35
“The correlation is not found in some studies with ambulatory recordings, exercise and sleep [2, 42].”
Background
Metadata
- Authors
- Khandoker, A. H., Karmakar, C. K., & Palaniswami, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2010-10-25
- Volume
- 33
- Issue
- 2
- Pages
- 204-209
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2111889024
- Cited by
- 98
- References
- 4
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.