Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)

Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M.J., Burriesci, G. · 2013 · Medical Engineering & Physics

Abstract

A better understanding of the mechanisms producing the radial force in transcatheter heart valves is essential in order to reduce the reported cases of migration and atrio-ventricular block and improve the effectiveness of the treatment. This paper presents a numerical study of the different mechanisms responsible for the radial force exerted on the aortic annulus by self-expanding and balloon-expandable prostheses. The behavior of the Medtronic CoreValve (self-expanding) and the Edwards SAPIEN (balloon-expandable) devices, both of size 26, has been simulated and compared. The results indicate that, for both prostheses, the radial force may vary considerably within the recommended functional range for the valve implantation and is substantially higher at the smallest annular sizes. In particular, in the case of the self-expanding valve the radial force is essentially dependent on the diameter of the left ventricular outflow tract, while for the balloon-expandable valve the radial force produced is influenced by both the geometry and stiffness of the host tissue. The outcomes of this study provide a better insight into the phenomenon and useful information that could support the development of improved solutions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2012.04.009

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., & Burriesci, G.
Venue
Medical Engineering & Physics
Published
2012-05-26
Volume
35
Issue
1
Pages
125-130
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2004657623
Cited by
179
References
2
FWCI
8.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). https://app.cochat.ai/papers/10.1016/j.medengphy.2012.04.009
The paper
Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., & Burriesci, G. (2013). Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2012.04.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.