The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)
Abstract
A better understanding of the mechanisms producing the radial force in transcatheter heart valves is essential in order to reduce the reported cases of migration and atrio-ventricular block and improve the effectiveness of the treatment. This paper presents a numerical study of the different mechanisms responsible for the radial force exerted on the aortic annulus by self-expanding and balloon-expandable prostheses. The behavior of the Medtronic CoreValve (self-expanding) and the Edwards SAPIEN (balloon-expandable) devices, both of size 26, has been simulated and compared. The results indicate that, for both prostheses, the radial force may vary considerably within the recommended functional range for the valve implantation and is substantially higher at the smallest annular sizes. In particular, in the case of the self-expanding valve the radial force is essentially dependent on the diameter of the left ventricular outflow tract, while for the balloon-expandable valve the radial force produced is influenced by both the geometry and stiffness of the host tissue. The outcomes of this study provide a better insight into the phenomenon and useful information that could support the development of improved solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iung, B. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00201-x · Cited by 3,530
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Self-citation
Cited by
Abdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., et al. (2014) · JAMA · doi:10.1001/jama.2014.3316 · Cited by 686
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Nazif, T. M., Dizon, J. M., Hahn, R. T., Xu, K., Babaliaros, V., Douglas, P. S., El-Chami, M. F., Herrmann, H. C., Mack, M., Makkar, R. R., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.07.022 · Cited by 532
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Metadata
- Authors
- Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., & Burriesci, G.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2012-05-26
- Volume
- 35
- Issue
- 1
- Pages
- 125-130
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2004657623
- Cited by
- 179
- References
- 2
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). https://app.cochat.ai/papers/10.1016/j.medengphy.2012.04.009
- The paper
- Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., & Burriesci, G. (2013). Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2012.04.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.