Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: 1) a method is described to create a consensus centerline with multiple observers, 2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, 3) a database containing thirty-two cardiac CTA datasets with corresponding reference standard is described and made available, and 4) thirteen coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Martin, D., Fowlkes, C., Tal, D., & Malik, J. (2002) · Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001 · doi:10.1109/iccv.2001.937655 · Cited by 8,216 · cited 2×
“Motivation The value of a standardized evaluation methodology and a publicly available image repository has been shown in a number of medical image analysis and general computer vision applications, for example in the Retrospective Image Registration Evaluation Project [14], the Digital Retinal Images for Vessel Extra…”
BackgroundA Taxonomy and Evaluation of Dense Two-Frame Stereo Correspondence Algorithms
Scharstein, D., & Szeliski, R. (2002) · International Journal of Computer Vision · doi:10.1023/a:1014573219977 · Cited by 6,740 · cited 1×
“, 2004), the Middlebury Stereo Vision evaluation (Scharstein and Szeliski, 2002), the Range Image Segmentation Comparison (Hoover et al.”
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202 · cited 1×
“The correspondence is determined with the algorithm explained in section 4.3.”
MethodInfluentialMedical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001 · cited 1×
“• GVFTube’n’Linkage [58]: This method uses a Gradient Vector Flow [59] based tube detection procedure for identification of vessels surrounded by arbitrary tissues [60, 61].”
MethodWriting Group Members, Rosamond, W., Flegal, K., Furie, K., Go, A., Greenlund, K., Haase, N., Hailpern, S. M., Ho, M., Howard, V., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.187998 · Cited by 3,711
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
Self-citationWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 1×
“Moreover, in order to get a good reference standard, annotations are needed from multiple observers and combining annotations from multiple observers is known to be difficult (Warfield et al., 2004) and until recently unexplored for three-dimensional curves (Walsum et al.”
BackgroundSelf-citationAccuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Cited by
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
“Open challenges, such as recently organized for liver segmentation [65] and coronary artery centerline extraction [66], would be an interesting way to compare image”
BackgroundA review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes
Lesage, D., Angelini, E. D., Bloch, I., & Funka-Lea, G. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.011 · Cited by 920
Evaluation of prostate segmentation algorithms for mri: The promise12 challenge
Litjens, G., Toth, R., van de Ven, W., Hoeks, C., Kerkstra, S., van Ginneken, B., Vincent, G., Guillard, G., Birbeck, N., Zhang, J., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.12.002 · Cited by 857
Qi, Y., He, Y., Qi, X., Zhang, Y., & Yang, G. (2023) · 2023 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv51070.2023.00558 · Cited by 617
Self-citationBlood vessel segmentation algorithms — Review of methods, datasets and evaluation metrics
Moccia, S., De Momi, E., El Hadji, S., & Mattos, L. S. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.02.001 · Cited by 567
State-of-the-Art Deep Learning in Cardiovascular Image Analysis
Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.06.009 · Cited by 388
Why rankings of biomedical image analysis competitions should be interpreted with care
Maier-Hein, L., Eisenmann, M., Reinke, A., Onogur, S., Stankovic, M., Scholz, P., Arbel, T., Bogunovic, H., Bradley, A. P., Carass, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07619-7 · Cited by 380
Self-citationLongitudinal multiple sclerosis lesion segmentation: Resource and challenge
Carass, A., Roy, S., Jog, A., Cuzzocreo, J. L., Magrath, E., Gherman, A., Button, J., Nguyen, J., Prados, F., Sudre, C. H., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.064 · Cited by 357
Self-citationA survey on skeletonization algorithms and their applications
Saha, P. K., Borgefors, G., & Sanniti di Baja, G. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2015.04.006 · Cited by 353
Wolterink, J. M., Leiner, T., de Vos, B. D., van Hamersvelt, R. W., Viergever, M. A., & Išgum, I. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.04.004 · Cited by 321
Computer-aided Diagnosis: How to Move from the Laboratory to the Clinic
van Ginneken, B., Schaefer-Prokop, C. M., & Prokop, M. (2011) · Radiology · doi:10.1148/radiol.11091710 · Cited by 306
Zreik, M., Lessmann, N., van Hamersvelt, R. W., Wolterink, J. M., Voskuil, M., Viergever, M. A., Leiner, T., & Išgum, I. (2018) · Medical Image Analysis · doi:10.1016/j.media.2017.11.008 · Cited by 216
“Manual delineation of the coronary rtery centerline is a time consuming and cumbersome task, and ost of the commercially available software packages occasionally equire substantial manual interaction, especially in images with xcessive atherosclerotic plaque or imaging artefacts ( Schaap et al., 009 ). A number of app…”
MethodWolterink, J. M., van Hamersvelt, R. W., Viergever, M. A., Leiner, T., & Išgum, I. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.10.005 · Cited by 207
Multiple hypothesis template tracking of small 3D vessel structures
Friman, O., Hindennach, M., Kühnel, C., & Peitgen, H.-O. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.003 · Cited by 180
Self-citationBig Heart Data: Advancing Health Informatics Through Data Sharing in Cardiovascular Imaging
Suinesiaputra, A., Medrano-Gracia, P., Cowan, B. R., & Young, A. A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2370952 · Cited by 45
Parallel centerline extraction on the GPU
Liu, B., Telea, A. C., Roerdink, J. B. T. M., Clapworthy, G. J., Williams, D., Yang, P., Dong, F., Codreanu, V., & Chiarini, A. (2014) · Computers & Graphics · doi:10.1016/j.cag.2014.02.003 · Cited by 14
Metadata
- Authors
- Schaap, M., Metz, C. T., van Walsum, T., van der Giessen, A. G., Weustink, A. C., Mollet, N. R., Bauer, C., Bogunović, H., Castro, C., Deng, X., Dikici, E., O’Donnell, T., Frenay, M., Friman, O., Hoyos, M. H., Kitslaar, P. H., Krissian, K., Kühnel, C., Luengo-Oroz, M. A., Orkisz, M., Smedby, Ö., Styner, M., Szymczak, A., Tek, H., Wang, C., Warfield, S. K., Zambal, S., Zhang, Y., Krestin, G. P., & Niessen, W. J.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 13
- Issue
- 5
- Pages
- 701-714
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2165023525
- Cited by
- 362
- References
- 29
- FWCI
- 19.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.