Automatic initialization and quality control of large-scale cardiac MRI segmentations
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
HighlightsA framework for LV detection, segmentation, and quality control in large CMR studies.Initialization and quality control steps that fully eliminate user intervention.An algorithm that uses large synthetic samples of image features and random forests.A quality control step that removes failed segmentations from subsequent analysis.A validation based on 1200+ healthy and abnormal cases from a large public database. Graphical abstract Figure. No Caption available. Abstract Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one‐stop‐shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three‐fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large‐scale cardiac MRI databases. The results obtained based on over 1200 cases from the Cardiac Atlas Project show the promise of fully automatic initialization and quality control for population studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Histograms of Oriented Gradients for Human Detection
Dalal, N., & Triggs, B. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.177 · Cited by 33,584
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190 · cited 12×
“The segmentation is performed based130 on a sparse ASM paradigm (SPASM) (van Assen et al., 2006), which uses statistical shape models (SSMs) of the heart to encode prior statistical knowledge about cardiac shape and MRI intensity in a training set.”
BackgroundMethodInfluentialLinear Model Selection by Cross-validation
Shao, J. (1993) · Journal of the American Statistical Association · doi:10.1080/01621459.1993.10476299 · Cited by 1,790 · cited 1×
“To evaluate the landmark detection, we conducted Monte Carlo Cross-Validation also known as repeated random sub-sampling cross-validation, which consists of repeated rounds of validation conducted on a fixed dataset (Shao, 1993).”
MethodBig Heart Data: Advancing Health Informatics Through Data Sharing in Cardiovascular Imaging
Suinesiaputra, A., Medrano-Gracia, P., Cowan, B. R., & Young, A. A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2370952 · Cited by 45
Self-citation
Cited by
Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge
Campello, V. M., Gkontra, P., Izquierdo, C., Martin-Isla, C., Sojoudi, A., Full, P. M., Maier-Hein, K., Zhang, Y., He, Z., Ma, J., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3090082 · Cited by 481
“The automation of such a tedious and timeconsuming task has been pursued for a long time by using multiple approaches, such as statistical shape models [3] or cardiac atlases [4].”
MethodSelf-citationKhened, M., Kollerathu, V. A., & Krishnamurthi, G. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.10.004 · Cited by 373
Medical image segmentation automatic quality control: A multi-dimensional approach
Fournel, J., Bartoli, A., Bendahan, D., Guye, M., Bernard, M., Rauseo, E., Khanji, M. Y., Petersen, S. E., Jacquier, A., & Ghattas, B. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102213 · Cited by 45
Luo, G., Dong, S., Wang, W., Wang, K., Cao, S., Tam, C., Zhang, H., Howey, J., Ohorodnyk, P., & Li, S. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101591 · Cited by 30
Metadata
- Authors
- Albà, X., Lekadir, K., Pereañez, M., Medrano-Gracia, P., Young, A. A., & Frangi, A. F.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2018-01
- Volume
- 43
- Pages
- 129-141
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2766085781
- Cited by
- 69
- References
- 7
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.