Adversarial attack vulnerability of medical image analysis systems: Unexplored factors
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Adversarial attacks are considered a potentially serious security threat for machine learning systems. Medical image analysis (MedIA) systems have recently been argued to be vulnerable to adversarial attacks due to strong financial incentives and the associated technological infrastructure. In this paper, we study previously unexplored factors affecting adversarial attack vulnerability of deep learning MedIA systems in three medical domains: ophthalmology, radiology, and pathology. We focus on adversarial black-box settings, in which the attacker does not have full access to the target model and usually uses another model, commonly referred to as surrogate model, to craft adversarial examples that are then transferred to the target model. We consider this to be the most realistic scenario for MedIA systems. Firstly, we study the effect of weight initialization (pre-training on ImageNet or random initialization) on the transferability of adversarial attacks from the surrogate model to the target model, i.e., how effective attacks crafted using the surrogate model are on the target model. Secondly, we study the influence of differences in development (training and validation) data between target and surrogate models. We further study the interaction of weight initialization and data differences with differences in model architecture. All experiments were done with a perturbation degree tuned to ensure maximal transferability at minimal visual perceptibility of the attacks. Our experiments show that pre-training may dramatically increase the transferability of adversarial examples, even when the target and surrogate’s architectures are different: the larger the performance gain using pre-training, the larger the transferability. Differences in the development data between target and surrogate models considerably decrease the performance of the attack; this decrease is further amplified by difference in the model architecture. We believe these factors should be considered when developing security-critical MedIA systems planned to be deployed in clinical practice. We recommend avoiding using only standard components, such as pre-trained architectures and publicly available datasets, as well as disclosure of design specifications, in addition to using adversarial defense methods. When evaluating the vulnerability of MedIA systems to adversarial attacks, various attack scenarios and target-surrogate differences should be simulated to achieve realistic robustness estimates. The code and all trained models used in our experiments are publicly available.3
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332 · cited 2×
“In the MedIA field, DL meth-ods commonly use pre-training on natural images to improve performance (Litjens et al., 2017).”
Self-citationExplaining and Harnessing Adversarial Examples
Goodfellow, I. J., Shlens, J., & Szegedy, C. (2014) · arXiv · doi:10.48550/arxiv.1412.6572 · Cited by 10,381
Towards Evaluating the Robustness of Neural Networks
Carlini, N., & Wagner, D. (2017) · 2017 IEEE Symposium on Security and Privacy (SP) · doi:10.1109/sp.2017.49 · Cited by 8,859
Intriguing properties of neural networks
Szegedy, C., Zaremba, W., Sutskever, I., Bruna, J., Erhan, D., Goodfellow, I., & Fergus, R. (2013) · arXiv · doi:10.48550/arxiv.1312.6199 · Cited by 8,143
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697 · cited 3×
“…to achieve close or even superior performance to that of experts in many medical image analysis (MedIA) applications, including in ophthalmology (Gulshan et al., 2016; Ting et al., 2017), radiology (Rajpurkar et al., 2017), and pathology (Bejnordi et al., 2017; Bulten et al., 2020; Wetstein et…”
Towards Deep Learning Models Resistant to Adversarial Attacks
Madry, A., Makelov, A., Schmidt, L., Tsipras, D., & Vladu, A. (2017) · arXiv · doi:10.48550/arxiv.1706.06083 · Cited by 6,602
Adversarial examples in the physical world
Kurakin, A., Goodfellow, I. J., & Bengio, S. (2018) · Artificial Intelligence Safety and Security · doi:10.1201/9781351251389-8 · Cited by 5,375
DeepFool: A Simple and Accurate Method to Fool Deep Neural Networks
Moosavi-Dezfooli, S.-M., Fawzi, A., & Frossard, P. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.282 · Cited by 5,317 · cited 2×
“…attacks (Szegedy et al., 2013; Goodfellow et al., 2014), whereas other methods optimize the attack in an iterative way (Madry et al., 2017; Kurakin et al., 2016; Papernot et al., 2016b; Moosavi-Dezfooli et al., 2016; Carlini and Wagner, 2017b; Su et al., 2019; Moosavi-Dezfooli et al., 2017).”
Wang, X., Peng, Y., Lu, L., Lu, Z., Bagheri, M., & Summers, R. M. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.369 · Cited by 4,616 · cited 2×
“…systems pre-trained on nat-ural images have shown to achieve improved performance in shorter training times in several medical applications (Gulshan et al., 2016; Wang et al., 2017), pre-training on ImageNet has become a common design choice for development of MedIA systems (Litjens et al., 2017).”
Cited by
MedViT: A robust vision transformer for generalized medical image classification
Manzari, O. N., Ahmadabadi, H., Kashiani, H., Shokouhi, S. B., & Ayatollahi, A. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106791 · Cited by 526
González-Gonzalo, C., Thee, E. F., Klaver, C. C. W., Lee, A. Y., Schlingemann, R. O., Tufail, A., Verbraak, F., & Sánchez, C. I. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101034 · Cited by 103
“In Gonz ´ alez-Gonzalo et al. (2020b), an additional image quality score is provided for a system that performs joint automated detection of DR and AMD in CFP.”
BackgroundMethodInfluentialSelf-citationRevisiting the Trustworthiness of Saliency Methods in Radiology AI
Zhang, J., Chao, H., Dasegowda, G., Wang, G., Kalra, M. K., & Yan, P. (2024) · Radiology: Artificial Intelligence · doi:10.1148/ryai.220221 · Cited by 57
Joel, M. Z., Umrao, S., Chang, E., Choi, R., Yang, D. X., Duncan, J. S., Omuro, A., Herbst, R., Krumholz, H. M., & Aneja, S. (2022) · JCO Clinical Cancer Informatics · doi:10.1200/cci.21.00170 · Cited by 51
Prabhudesai, S., Wang, N. C., Ahluwalia, V., Huan, X., Bapuraj, J. R., Banovic, N., & Rao, A. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.740353 · Cited by 13
“Recent work has shown the importance to evaluate the models’ abilities to withstand adversarial attacks, especially in high-stakes scenarios such as radiology (Wetstein et al., 2020).”
Metadata
- Authors
- Bortsova, G., González-Gonzalo, C., Wetstein, S. C., Dubost, F., Katramados, I., Hogeweg, L., Liefers, B., van Ginneken, B., Pluim, J. P. W., Veta, M., Sánchez, C. I., & de Bruijne, M.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2021-10
- Volume
- 73
- Pages
- 102141
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W3035751626
- Cited by
- 126
- References
- 32
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.