Effectiveness of artificial pancreas in the non-adult population: A systematic review and network meta-analysis
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE Artificial pancreas is a technology that minimizes user input by bridging continuous glucose monitoring and insulin pump treatment, and has proven safety in the adult population. The purpose of this systematic review and meta-analysis is to evaluate the efficacy of closed-loop (CL) systems in the glycemic control of non-adult type 1 diabetes patients in both a pairwise and network meta-analysis (NMA) context and investigate various parameters potentially affecting the outcome. METHODS Literature was systematically searched using the MEDLINE (1966-2018), Scopus (2004-2018), Cochrane Central Register of Controlled Trials (CENTRAL) (1999-2018), Clinicaltrials.gov (2008-2018) and Google Scholar (2004-2018) databases. Studies comparing the glycemic control in CL (either single- or dual-hormone) with continuous subcutaneous insulin infusion (CSII) in people with diabetes (PWD) aged <18 years old were deemed eligible. The primary outcome analysis was conducted with regard to time spent in the target glycemic range. All outcomes were evaluated in NMA in order to investigate potential between-algorithm differences. Pairwise meta-analysis and meta-regression were performed using the RevMan 5.3 and Open Meta-Analyst software. For NMA, the package pcnetmetain R 3.5.1 was used. RESULTS The meta-analysis was based on 25 studies with a total of 504 PWD. The CL group was associated with significantly higher percentage of time spent in the target glycemic range (Mean (SD): 67.59% (SD: 8.07%) in the target range and OL PWD spending 55.77% (SD: 11.73%), MD: -11.97%, 95% CI [-18.40, -5.54%]) and with lower percentages of time in hyperglycemia (MD: 3.01%, 95% CI [1.68, 4.34%]) and hypoglycemia (MD: 0.67%, 95% CI [0.21, 1.13%]. Mean glucose was also decreased in the CL group (MD: 0.75 mmol/L, 95% CI [0.18-1.33]). The NMA arm of the study showed that the bihormonal modality was superior to other algorithms and standard treatment in lowering mean glucose and increasing time spent in the target range. The DiAs platform was superior to PID in controlling hypoglycemia and mean glucose. Time in target range and mean glucose were unaffected by the confounding factors tested. CONCLUSIONS The findings of this meta-analysis suggest that artificial pancreas systems are superior to the standard sensor-augmented pump treatment of type 1 diabetes mellitus in non-adult PWD. Between-algorithm differences are also addressed, implying a superiority of the bihormonal treatment modality. Future large-scale studies are needed in the field to verify these outcomes and to determine the optimal algorithm to be used in the clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s062 · Cited by 5,491
Epidemiology of type 1 diabetes
Maahs, D. M., West, N. A., Lawrence, J. M., & Mayer-Davis, E. J. (2010) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2010.05.011 · Cited by 1,092
The appropriateness of asymmetry tests for publication bias in meta-analyses: A large survey
Ioannidis, J. P. A., & Trikalinos, T. A. (2007) · Canadian Medical Association Journal · doi:10.1503/cmaj.060410 · Cited by 1,052 · cited 1×
“Publication bias was evaluated by the visual inspection of funnel plots, since the high inter-study heterogeneity precluded the safe interpretation of the available statistical tests [17].”
MethodWeisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463 · cited 3×
“Thisfinding is in agreement with the respective findings of two recent meta-analyses [13,51], inwhich both adult and pediatric populationswere included.”
BackgroundResultHome Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450 · cited 1×
“The only available information comes from one study [25], which reported a non-significant decrease (−0.”
BackgroundBekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
Breton, M. D., Cherñavvsky, D. R., Forlenza, G. P., DeBoer, M. D., Robic, J., Wadwa, R. P., Messer, L. H., Kovatchev, B. P., & Maahs, D. M. (2017) · Diabetes Care · doi:10.2337/dc17-0883 · Cited by 179 · cited 2×
“21, I(2)=37%) after the exclusion of 5 studies [32,37,38,41,43].”
BackgroundDel Favero, S., Boscari, F., Messori, M., Rabbone, I., Bonfanti, R., Sabbion, A., Iafusco, D., Schiaffini, R., Visentin, R., Calore, R., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2815 · Cited by 94
Huyett, L. M., Ly, T. T., Forlenza, G. P., Reuschel-DiVirgilio, S., Messer, L. H., Wadwa, R. P., Gondhalekar, R., Doyle, F. J., Pinsker, J. E., Maahs, D. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0399 · Cited by 64 · cited 2×
“In time in hypoglycemia analysis, the exclusion of 3 studies [29,35,40] showed a more homogeneous (I(2) = 28%) but still significant mean difference favoring CL (Means (SD): 2.”
Background
Cited by
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Dhatariya, K. K., Glaser, N. S., Codner, E., & Umpierrez, G. E. (2020) · Nature Reviews Disease Primers · doi:10.1038/s41572-020-0165-1 · Cited by 461
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Metadata
- Authors
- Karageorgiou, V., Papaioannou, T. G., Bellos, I., Alexandraki, K., Tentolouris, N., Stefanadis, C., Chrousos, G. P., & Tousoulis, D.
- Venue
- Metabolism
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 90
- Pages
- 20-30
- ISSN
- 0026-0495 (ISSN-L)
- OpenAlex
- W2897839932
- Cited by
- 89
- References
- 10
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effectiveness of artificial pancreas in the non-adult population: A systematic review and network meta-analysis. https://app.cochat.ai/papers/10.1016/j.metabol.2018.10.002
- The paper
- Karageorgiou, V., Papaioannou, T. G., Bellos, I., Alexandraki, K., Tentolouris, N., Stefanadis, C., Chrousos, G. P., & Tousoulis, D. (2019). Effectiveness of artificial pancreas in the non-adult population: A systematic review and network meta-analysis. Metabolism. https://doi.org/10.1016/j.metabol.2018.10.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.