CoChat

Temperature-controlled liquid–liquid microextraction using a biocompatible hydrophobic deep eutectic solvent for microextraction of palladium from catalytic converter and road dust samples prior to ETAAS determination

Abdi, Khosrou, Ezoddin, Maryam, Pirooznia, Nazanin · 2020 · Microchemical Journal
Cited by 55

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

A simple method based on temperature-controlled liquid–liquid microextraction (TC-LLME) using a novel hydrophobic deep eutectic solvent (DES) was developed for preconcentration of palladium. Deep eutectic solvent based on phenyl salicylate (salol) and DL-menthol (1:1) was used as the extraction solvent. The control of temperature enhanced the dispersion of deep eutectic solvent and a homogeneous solution was made. Upon cooling the solution in an ice bath, a cloudy solution was formed. Afterwards, the mixture was centrifuged and the sediment phase was analyzed by Electrothermal Atomic Absorption Spectroscopy (ETAAS). To improve the extraction efficiency, the main parameters were optimized. Under the optimized extraction conditions, the limit of detection (LOD) and limit of quantification (LOQ) were 0.03 μg L−1 and 0.10 μg L−1 respectively. Preconcentration factor was obtained 191. The precision, expressed as the relative standard deviation (RSD, n = 10), found to be 4.6%. Finally, the method was an effective procedure for the determination of palladium in water, catalytic converter and road dust samples with acceptable extraction recoveries of 95.1% to 100.4%. The obtained results confirmed the ability of the developed method in the different samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.microc.2020.104999

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 29

  1. P. Patnaik Handbook of Inorganic Chemicals, The McGraw-Hill Companies 2003 New York, USA 686.
  2. M. Nemakal S. Aralekallu I. Mohammed K.P. C.P., L. Koodlur Sannegowda, Chemisorbed palladium phthalocyanine for simultaneous determination of biomolecules Microchemical Journal 143 2018 82 91. · DOI
  3. Dobrzyńska, 2019, Palladium adsorption and preconcentration onto thiol- and amine-functionalized mesoporous silicas with respect to analytical applications, Microporous Mesoporous Mater., 274, 127, 10.1016/j.micromeso.2018.07.038 · DOI
  4. Van Loon, 1999, Recent advances in the determination of the platinum group elements and gold, Talanta, 49, 1, 10.1016/S0039-9140(98)00347-6 · doi:10.1016/s0039-9140(98)00347-6
  5. Ravindra, 2004, Platinum group elements in the environment and their health risk, Sci. Total Environ., 318, 1, 10.1016/S0048-9697(03)00372-3 · DOI · Paper page
  6. Alimohammadi, 2019, Utilization of a robust syringe-to-syringe displacement-assisted dispersive liquid-phase microextraction to the preconcentration and determination of palladium in environmental samples with the aid of experimental design, J Iran Chem Soc., 1
  7. Butcher, 2017, Recent highlights in graphite furnace atomic absorption spectrometry, Appl. Spect. Rev., 52, 755, 10.1080/05704928.2017.1303504 · doi:10.1080/05704928.2017.1303504
  8. Zhang, 2015, A rapid and practical strategy for the determination of platinum, palladium, ruthenium, rhodium, iridium and gold in large amounts of ultrabasic rock by inductively coupled plasma optical emission spectrometry combined with ultrasound extraction, Opt. Spectrosc., 118, 513, 10.1134/S0030400X15040049 · doi:10.1134/s0030400x15040049
  9. Leśniewska, 2006, Elimination of interferences in determination of platinum and palladium in environmental samples by inductively coupled plasma mass spectrometry, Anal. Chim. Acta, 564, 236, 10.1016/j.aca.2006.01.066 · doi:10.1016/j.aca.2006.01.066
  10. Farajvand, 2017, Optimization of solvent terminated dispersive liquid–liquid micro-extraction of copper ions in water and food samples using artificial neural networks coupled bee algorithm, Bull Environ Contam Toxicol., 100, 402, 10.1007/s00128-017-2263-7 · DOI
  11. Liu, 2018, Determination of ultra-trace Pt, Pd and Rh in seawater using an off-line pre-concentration method and inductively coupled plasma mass spectrometry, Chemosphere, 212, 429, 10.1016/j.chemosphere.2018.08.098 · DOI
  12. da Luz Potes, 2019, Investigation of the conditions for selenium determination by photochemical vapor generation coupled to graphite furnace atomic absorption spectrometry, Microchem J., 147, 324, 10.1016/j.microc.2019.03.053 · DOI
  13. Habila, 2019, A new amine based microextraction of lead (II) in real water samples using flame atomic absorption spectrometry, Microchem J., 148, 214, 10.1016/j.microc.2019.04.078 · DOI
  14. Amirifard, 2018, Preconcentration of Pd ion in novel modified magnetic graphene oxide nanoparticles in different samples and its determination by ETAAS, Environ. Nanotechnol. Monit Manag., 10, 140
  15. Hasegawa, 2018, Selective recovery of gold, palladium, or platinum from acidic waste solution, Microchem J., 139, 174, 10.1016/j.microc.2018.02.025 · doi:10.1016/j.microc.2018.02.025
  16. Anthemidis, 2001, Stopped-flow injection liquid–liquid extraction spectrophotometric determination of palladium in airborne particulate matter and automobile catalysts, Talanta, 54, 37, 10.1016/S0039-9140(00)00620-2 · DOI
  17. Ghaedi, 2009, Cloud point extraction and flame atomic absorption spectrometric determination of cadmium(II), lead(II), palladium(II) and silver(I) in environmental samples, J. Hazard. Mater., 168, 1022, 10.1016/j.jhazmat.2009.02.130 · DOI · Paper page
  18. Tavakoli, 2008, Development of cloud point extraction forsimulta- neous extraction and determination of gold and palladium using ICP-OES, J. Hazard. Mater., 152, 737, 10.1016/j.jhazmat.2007.07.039 · DOI
  19. Ezoddin, 2015, Ultrasound-assisted supramolecular dispersive liquid–liquid microextraction based on solidification of floating organic drops for preconcentration of palladium in water and road dust samples, J Mol Liq., 209, 515, 10.1016/j.molliq.2015.06.031 · DOI
  20. Pouyan, 2016, Determination of ultra-trace palladium (II) in water, soil, and food samples by dispersive liquid-liquid microextraction-atomic absorption spectrometry using 2-mercaptobenzimidazole as a complexing agent, Microchem. J., 127, 46, 10.1016/j.microc.2016.02.003 · DOI
  21. Kokya, 2009, Optimization of dispersive liquid–liquid microextraction for the selective determination of trace amounts of palladium by flame atomic absorption spectroscopy, J. Hazard. Mater., 169, 726, 10.1016/j.jhazmat.2009.04.005 · DOI
  22. Ragheb, 2015, A Novel Dispersive Liquid-Liquid Microextraction Method Based on Solidification of Floating Organic Drop for Preconcentration of Pd(II) by Graphite Furnace Atomic Absorption Spectrometry after Complexation by a Thienyl Substituted 1,2-Ethanediamine, Anal Sci., 31, 119, 10.2116/analsci.31.119 · DOI
  23. Abbott, 2003, V. Tambyrajah, Novel solvent properties of choline chloride/urea mixtures, Chem. Commun., 1, 70, 10.1039/b210714g · DOI · Paper page
  24. Zarei, 2017, Deep eutectic solvent based magnetic nanofluid in the development of stir bar sorptive dispersive microextraction: an efficient hyphenated sample preparation for ultra-trace nitroaromatic explosives extraction in wastewater, J Sep Sci., 4757, 10.1002/jssc.201700915 · DOI · Paper page
  25. Lamei, 2017, Dispersion of magnetic grapheme oxide nanoparticles coated with a deep eutectic solvent using ultrasound assistance for preconcentration of methadone in biological and water samples followed by GC–FID and GC–MS, Anal. Bioanal. Chem., 409, 6113, 10.1007/s00216-017-0547-8 · DOI · Paper page
  26. F. Kamarei, H. Ebrahimzadeh, Y. Yamini. Optimization of temperature-controlled ionic liquid dispersive liquid phase microextraction combined with high performance liquid chromatography for analysis of chlorobenzenes in water samples, Talanta83 (2010)36–41. https://doi.org/10.1016/j.talanta.2010.08.035. · DOI
  27. M. Nedaei, A. R. Zarei, S. A. Ghorbanian, Development of a new emulsification microextraction method based on solidification of settled organic drop: Application of novel ultra-hydrophobic tailor-made deep eutectic solvent. New Journal of Chemistry.
  28. Amin, 2016, Utility of cloud-point preconcentration and spectrophotometry for determination of trace amounts of palladium(II) and their analytical applications, Arabian J. Chem., 9, S326, 10.1016/j.arabjc.2011.04.003 · doi:10.1016/j.arabjc.2011.04.003
  29. Ezoddin, 2016, Development of air assisted liquid phase microextraction based on switchable-hydrophilicity solvent for the determination of palladium in environmental samples, Talanta, 153, 247, 10.1016/j.talanta.2016.03.018 · DOI

Metadata

Authors
Abdi, K., Ezoddin, M., & Pirooznia, N.
Venue
Microchemical Journal
Publisher
Elsevier BV
Published
2020-09
Volume
157
Pages
104999
ISSN
0026-265X (ISSN-L)
OpenAlex
W3022597750
Cited by
55
References
5
FWCI
4.82
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temperature-controlled liquid–liquid microextraction using a biocompatible hydrophobic deep eutectic solvent for microextraction of palladium from catalytic converter and road dust samples prior to ETAAS determination. https://app.cochat.ai/papers/10.1016/j.microc.2020.104999
The paper
Abdi, K., Ezoddin, M., & Pirooznia, N. (2020). Temperature-controlled liquid–liquid microextraction using a biocompatible hydrophobic deep eutectic solvent for microextraction of palladium from catalytic converter and road dust samples prior to ETAAS determination. Microchemical Journal. https://doi.org/10.1016/j.microc.2020.104999

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.