Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion MRI due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whole brain, removing them in advance should enhance the CBF quantification quality for ASL MRI. The purpose of this paper was to assess this potential benefit. Three methods were proposed to suppress each or both of the two global nuisances. Their performances for CBF quantification were validated using ASL data acquired from 13 subjects. Evaluation results showed that covarying out both global nuisances significantly improved temporal SNR and test-retest stability of CBF measurement. Although the concept of removing both nuisances is not technically novel per se, this paper clearly showed the benefits for ASL CBF quantification. Dissemination of the proposed methods in a free ASL data processing toolbox should be of interest to a broad range of ASL users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Brain's Default Network: Anatomy, Function, and Relevance to Disease
Buckner, R. L., Andrews‐Hanna, J. R., & Schacter, D. L. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1440.011 · Cited by 9,761
Spontaneous fluctuations in brain activity observed with functional magnetic resonance imaging
Fox, M. D., & Raichle, M. E. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2201 · Cited by 6,700 · cited 1×
“Removal of whole brain global signal has long been discussed in the BOLD fMRI literature [16–19], but still not explicitly addressed in ASL MRI.”
A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
Behzadi, Y., Restom, K., Liau, J., & Liu, T. T. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.042 · Cited by 4,502 · cited 1×
“It has also been adapted in ASL MRI for confound removal [22,23] and for CBF quantification in Ref.”
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Murphy, K., Birn, R. M., Handwerker, D. A., Jones, T. B., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.036 · Cited by 2,387
The global signal and observed anticorrelated resting state brain networks
Fox, M. D., Zhang, D., Snyder, A. Z., & Raichle, M. E. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90777.2008 · Cited by 1,877 · cited 1×
“Removing global signal has been skeptical in BOLD fMRI due to the possibility of introducing apparent anti-correlations [26–28].”
A method for removal of global effects from fMRI time series
Macey, P. M., Macey, K. E., Kumar, R., & Harper, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.042 · Cited by 407 · cited 1×
“Removal of whole brain global signal has long been discussed in the BOLD fMRI literature [16–19], but still not explicitly addressed in ASL MRI.”
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403 · cited 1×
“Since the spectrum of ASL perfusion signal tends to be flat [7], the noise in the subtracted ASL perfusion data tends to be white noise.”
Arterial spin labeling perfusion fMRI with very low task frequency
Wang, J., Aguirre, G. K., Kimberg, D. Y., Roc, A. C., Li, L., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10437 · Cited by 316 · cited 1×
“(1) can be used as the baseline MR signal M0, and CBF can be calculated with f = βidealλR1aexp ωR1a ð Þ 2cα 1−exp −τR1a ð Þ 1⁄2 , where f is CBF, R1a is the longitudinal relaxation rate of blood,τ is the labeling time, ω is the post labeling delay time, α is the labeling efficiency and λ is blood/tissue water partitio…”
Cited by
Towards a consensus regarding global signal regression for resting state functional connectivity MRI
Murphy, K., & Fox, M. D. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.052 · Cited by 1,048
Psychedelic drugs: neurobiology and potential for treatment of psychiatric disorders
Vollenweider, F. X., & Preller, K. H. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-020-0367-2 · Cited by 570
Akeju, O., Loggia, M. L., Catana, C., Pavone, K. J., Vazquez, R., Rhee, J., Contreras Ramirez, V., Chonde, D. B., Izquierdo-Garcia, D., Arabasz, G., et al. (2014) · eLife · doi:10.7554/elife.04499 · Cited by 168
Targeted genetic analysis of cerebral blood flow imaging phenotypes implicates the INPP5D gene
Yao, X., Risacher, S. L., Nho, K., Saykin, A. J., Wang, Z., & Shen, L. (2019) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2019.06.003 · Cited by 40
“ASL images were processed with the following steps: motion correction (MoCo) (Wang, 2012), temporal denoising, spatial smoothing, CBF quantification, outlier cleaning, partial volume correction (PVC) (Hu et al., 2010), spatial registration to the Montreal Neurology Institute (MNI) standard brain…”
MethodSelf-citation
Metadata
- Authors
- Wang, Z.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 30
- Issue
- 10
- Pages
- 1409-1415
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2007543006
- Cited by
- 157
- References
- 11
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations. https://app.cochat.ai/papers/10.1016/j.mri.2012.05.004
- The paper
- Wang, Z. (2012). Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2012.05.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.