Susceptibility-Weighted Imaging: Clinical Angiographic Applications
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
By combining filtered phase and magnitude information to create a novel and intrinsic source of contrast, susceptibility-weighted imaging (SWI) has shown great promise in clinical angiography and venography. SWI has contributed to new insights into traumatic brain injury, the role of calcification in atherosclerosis, and the possible relationship between blood settling and deep venous thrombosis. A further contribution from SWI to deep venous thrombosis research (and also stroke) involves its application to the noninvasive measurement of oxygen saturation in the brain and in other tissues. Altogether, SWI offers manifold and diverse avenues for further research using angiographic and venographic techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582 · cited 1×
“It has been shown that four multiplications produces good contrast-to-noise for a wide range of phase values.(32) In each individual slice, the veins now appear dark and look likea setofcircles orvessel cross-sections.”
BackgroundSelf-citationImaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Self-citationCostes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101
Comparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98
Cited by
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Self-citationSusceptibility mapping as a means to visualize veins and quantify oxygen saturation
Haacke, E. M., Tang, J., Neelavalli, J., & Cheng, Y. C. N. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22276 · Cited by 306
Self-citationA review of neuroimaging findings in repetitive brain trauma
Koerte, I. K., Lin, A. P., Willems, A., Muehlmann, M., Hufschmidt, J., Coleman, M. J., Green, I., Liao, H., Tate, D. F., Wilde, E. A., et al. (2015) · Brain Pathology · doi:10.1111/bpa.12249 · Cited by 160
“In what follows we introduce the concept of mTBI before describing repetitive concussive brain trauma and repetitive subconcussive head impacts/brain trauma.”
MethodInfluentialMehta, R. I., Carpenter, J. S., Mehta, R. I., Haut, M. W., Wang, P., Ranjan, M., Najib, U., D’Haese, P.-F., & Rezai, A. R. (2023) · Fluids and Barriers of the CNS · doi:10.1186/s12987-023-00447-y · Cited by 74
Metadata
- Authors
- Barnes, S. R. S., & Haacke, E. M.
- Venue
- Magnetic Resonance Imaging Clinics of North America
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 17
- Issue
- 1
- Pages
- 47-61
- ISSN
- 1064-9689 (ISSN-L)
- OpenAlex
- W2152590731
- Cited by
- 117
- References
- 4
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Susceptibility-Weighted Imaging: Clinical Angiographic Applications. https://app.cochat.ai/papers/10.1016/j.mric.2008.12.002
- The paper
- Barnes, S. R. S., & Haacke, E. M. (2009). Susceptibility-Weighted Imaging: Clinical Angiographic Applications. Magnetic Resonance Imaging Clinics of North America. https://doi.org/10.1016/j.mric.2008.12.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.