The DOI matches its Crossref record.
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents
Open accessAbstract
Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Self-citationAntibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Self-citationZinc-based biomaterials for regeneration and therapy
Su, Y., Cockerill, I., Wang, Y., Qin, Y.-X., Chang, L., Zheng, Y., & Zhu, D. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.10.009 · Cited by 417
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Metadata
- Authors
- Bowen, P. K., Guillory, R. J., Shearier, E. R., Seitz, J.-M., Drelich, J., Bocks, M., Zhao, F., & Goldman, J.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 56
- Pages
- 467-472
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W932876511
- Cited by
- 261
- References
- 0
- FWCI
- 18.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents. https://app.cochat.ai/papers/10.1016/j.msec.2015.07.022
- The paper
- Bowen, P. K., Guillory, R. J., Shearier, E. R., Seitz, J.-M., Drelich, J., Bocks, M., Zhao, F., & Goldman, J. (2015). Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2015.07.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.