Degradation mechanisms and future challenges of titanium and its alloys for dental implant applications in oral environment
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
OBJECTIVE For many decades the failure of titanium implants due to corrosion and wear were approached individually and their synergic effect was not considered. In recent past, developments and understanding of the tribocorrosion aspects have thrown deeper understanding on the failure of implants and this has been reviewed in this article extensively. METHODS Medline, google scholar and Embase search was conducted to identify studies published between 1993 and 2016 which were related to the analysis of degradation mechanism which the dental implants undergo after implantation. RESULTS In-vitro tests has been extensively carried out to evaluate the tribocorrosion behavior of titanium based dental implants. However, there is still a lack of knowledge about the tangible behavior of materials under in-vivo condition, because the in-vitro experiments are conducted using different testing protocols and conditions (solutions, pH, time, equipment, and testing parameters). Hence, there is an urgent need to perform round-robin test in different laboratories which will help to overcome the gap between in-vitro and in-vivo conditions. CONCLUSION Tribocorrosion has been identified as the major degradation mechanisms that result in the failure of dental implants. Hence, it is of utmost importance to improve the service period of dental implants by reducing the tribocorrosion effects through developing new dental implant materials using nobler alloying elements or through modifying the surface of the implants. In order to have a thorough understanding of tribocorrosion behavior and failure mechanisms, round robin test are to be conducted and new protocols/standards are to be developed for the testing of implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Wang, W. H., Dong, C., & Shek, C. H. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.03.001 · Cited by 2,803
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Fauchais, P. L., Heberlein, J. V. R., & Boulos, M. I. (2014) · Springer eBooks · doi:10.1007/978-0-387-68991-3 · Cited by 857
A review on the wettability of dental implant surfaces II: Biological and clinical aspects
Gittens, R. A., Scheideler, L., Rupp, F., Hyzy, S. L., Geis-Gerstorfer, J., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.032 · Cited by 849
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia
Osman, R. B., & Swain, M. V. (2015) · Materials · doi:10.3390/ma8030932 · Cited by 664
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A., Ghazali, M. J., Razali, M., & Otsuka, Y. (2015) · BioMed Research International · doi:10.1155/2015/791725 · Cited by 611
Otsuki, B., Takemoto, M., Fujibayashi, S., Neo, M., Kokubo, T., & Nakamura, T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.013 · Cited by 574
Cochran, D. L., Buser, D., Ten Bruggenkate, C. M., Weingart, D., Taylor, T. M., Bernard, J., Peters, F., & Simpson, J. P. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130204.x · Cited by 568
Processing and biocompatibility evaluation of laser processed porous titanium
Xue, W., Krishna, B. V., Bandyopadhyay, A., & Bose, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.05.009 · Cited by 471
A Brief Historical Perspective on Dental Implants, Their Surface Coatings and Treatments
Abraham, C. M. (2014) · The Open Dentistry Journal · doi:10.2174/1874210601408010050 · Cited by 298
An overview of the corrosion aspect of dental implants (titanium and its alloys)
Chaturvedi, T. P. (2009) · Indian Journal of Dental Research · doi:10.4103/0970-9290.49068 · Cited by 297
The effects on bone cells of metal ions released from orthopaedic implants. A review
Sansone, V (2013) · CLINICAL CASES IN MINERAL AND BONE METABOLISM · doi:10.11138/ccmbm/2013.10.1.034 · Cited by 289
Roy, M., Bandyopadhyay, A. K., & Bose, S. (2010) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2010.10.042 · Cited by 288
Surface Engineering for Bone Implants: A Trend from Passive to Active Surfaces
Bosco, R., Van Den Beucken, J., Leeuwenburgh, S., & Jansen, J. (2012) · Coatings · doi:10.3390/coatings2030095 · Cited by 265
Titanium allergy: could it affect dental implant integration?
Siddiqi, A., Payne, A. G. T., De Silva, R. K., & Duncan, W. J. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02081.x · Cited by 222
Thermal Sprayed Coatings Used Against Corrosion and Corrosive Wear
Fauchais, P. L., & Vardelle, A. M. (2012) · InTech eBooks · doi:10.5772/34448 · Cited by 177
Tribo-electrochemical characterization of metallic biomaterials for total joint replacement
Diomidis, N., Mischler, S., More, N. S., & Roy, M. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.034 · Cited by 161
Dental implants: Maintenance, care and treatment of peri‐implant infection
Chen, S., & Darby, I. B. (2003) · Australian Dental Journal · doi:10.1111/j.1834-7819.2003.tb00034.x · Cited by 122
Mathew, M. T., Abey, S., Hallab, N. J., Hall, D. J., Sukotjo, C., & Wimmer, M. A. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32735 · Cited by 120
Thermal plasma processing of materials: A review
Taylor, P. R., & Pirzada, S. A. (1994) · Advanced Performance Materials · doi:10.1007/bf00705312 · Cited by 93
The influence of proteins on the fretting–corrosion behaviour of a Ti6Al4V alloy
Hiromoto, S., & Mischler, S. (2006) · Wear · doi:10.1016/j.wear.2006.03.032 · Cited by 93
Advanced Plasma Spray Applications
(2012) · doi:10.5772/1921 · Cited by 81
In vitro and in vivo studies on Ti-based bulk metallic glass as potential dental implant material
Wang, Y. B., Li, H., Cheng, Y., Zheng, Y., & Ruan, L. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.04.038 · Cited by 76
Tribocorrosion behavior of veneering biomedical PEEK to Ti6Al4V structures
Sampaio, M., Buciumeanu, M., Henriques, B. A. P. D. C., Silva, F. S., Souza, J. C. M., & Gomes, J. R. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.09.010 · Cited by 76
Nanostructured Surfaces of Dental Implants
Bressan, E. A., Sbricoli, L., Guazzo, R., Tocco, I., Roman, M., Vindigni, V., Stellini, E., Gardin, C., Ferroni, L., Sivolella, S., et al. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms14011918 · Cited by 76
Insights into Surface Treatment Methods of Titanium Dental Implants
Guo, C. Y., Tang, A. T. H., & Matinlinna, J. P. (2012) · Journal of Adhesion Science and Technology · doi:10.1163/016942411x569390 · Cited by 71
Drago, C. J. (2003) · PubMed · Cited by 55
Mechanical characteristics and corrosion behavior of (Ti,Al)N coatings on dental alloys
Liu, G. T., Duh, J., CHUNG, K. ‐., & Wang, J. H. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.07.124 · Cited by 46
Tribocorrosion and bio-tribocorrosion in the oral environment : the case of dental implants
Cruz, H. M. V., Souza, J. C. M., Henriques, M., & Rocha, L. A. (2011) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 42
Faverani, L. P., Barão, V. A. R., Pires, M. F. A., Yuan, J. C., Sukotjo, C., Mathew, M. T., & Assunção, W. G. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.06.033 · Cited by 35
Titanium dental implant surfaces
Elias, C. N. (2010) · Matéria (Rio de Janeiro) · doi:10.1590/s1517-70762010000200008 · Cited by 28
Dental Implant Surfaces – Physicochemical Properties, Biological Performance, and Trends
Ahmed, M. H., Omar, O., Xia, W., & Palmquist, A. (2011) · InTech eBooks · doi:10.5772/17512 · Cited by 27
Ostrovska, L., Vištějnová, L., Džugan, J., Sláma, P., Kubina, T., Ukraintsev, E., Kubies, D., Králíčková, M., & Kalbáčová, M. H. (2015) · Journal of Materials Science · doi:10.1007/s10853-015-9619-3 · Cited by 24
Cited by
Soft Bioelectronics Based on Nanomaterials
Cho, K. W., Sunwoo, S.-H., Hong, Y. J., Koo, J. H., Kim, J. H., Baik, S., Hyeon, T., & Kim, D.-H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00531 · Cited by 244
Recent progress on parylene C polymer for biomedical applications: A review
Golda-Cepa, M., Engvall, K., Hakkarainen, M., & Kotarba, A. (2020) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2019.105493 · Cited by 197
Fit and forget: The future of dental implant therapy via nanotechnology
Gulati, K., Chopra, D., Kocak-Oztug, N. A., & Verron, E. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114900 · Cited by 89
Metadata
- Authors
- Revathi, A., Borrás, A. D., Muñoz, A. I., Richard, C., & Manivasagam, G.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2017-07
- Volume
- 76
- Pages
- 1354-1368
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2592262327
- Cited by
- 182
- References
- 35
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.