The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Open accessAbstract
It is still an open challenge to find a biodegradable metallic material exhibiting sufficient mechanical properties and degradation behavior to serve as an arterial stent. In this study, Zn-Mg alloys of 0.002 (Zn-002Mg), 0.005 (Zn-005Mg) and 0.08 wt% Mg (Zn-08Mg) content were cast, extruded and drawn to 0.25 mm diameter, and evaluated as potential biodegradable stent materials. Structural analysis confirmed formation of Mg2Zn11 intermetallic in all three alloys with the average grain size decreasing with increasing Mg content. Tensile testing, fractography analysis and micro hardness measurements showed the best integration of strength, ductility and hardness for the Zn-08Mg alloy. Yield strength, tensile strength, and elongation to failure values of >200–300 MPa, >300–400 MPa, and >30% respectively, were recorded for Zn-08Mg. This metal appears to be the first formulated biodegradable material that satisfies benchmark values desirable for endovascular stenting. Unfortunately, the alloy reveals signs of age hardening and strain rate sensitivity, which need to be addressed before using this metal for stenting. The explants of Zn-08Mg alloy residing in the abdominal aorta of adult male Sprague-Dawley rats for 1.5, 3, 4.5, 6 and 11 months demonstrated similar, yet slightly elevated inflammation and neointimal activation for the alloy relative to what was recently reported for pure zinc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Hansen, M., Anderko, K., & Salzberg, H. W. (1958) · Journal of The Electrochemical Society · doi:10.1149/1.2428700 · Cited by 14,782
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Hall–Petch relation and boundary strengthening
Hansen, N. (2004) · Scripta Materialia · doi:10.1016/j.scriptamat.2004.06.002 · Cited by 3,799
Saris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
Self-citationErbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S. (2007) · Circulation · doi:10.1161/circulationaha.106.658237 · Cited by 839
Cited by
Alloying design of biodegradable zinc as promising bone implants for load-bearing applications
Yang, H., Jia, B., Zhang, Z., Qu, X., Li, G., Lin, W., Zhu, D., Dai, K., & Zheng, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-14153-7 · Cited by 756
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Self-citationFundamental Theory of Biodegradable Metals—Definition, Criteria, and Design
Liu, Y., Zheng, Y., Chen, X., Yang, J., Pan, H., Chen, D., Wang, L., Zhang, J., Zhu, D., Wu, S., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805402 · Cited by 519
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Current status and perspectives of zinc-based absorbable alloys for biomedical applications
Hernández-Escobar, D., Champagne, S., Yilmazer, H., Dikici, B., Boehlert, C. J., & Hermawan, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.034 · Cited by 309
Zheng, Y., Huang, C., Li, Y., Gao, J., Yang, Y., Zhao, S., Che, H., Yang, Y., Yao, S., Li, W., et al. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.05.023 · Cited by 63
Self-citation
Metadata
- Authors
- Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2018-03
- Volume
- 84
- Pages
- 67-79
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2768779222
- Cited by
- 271
- References
- 57
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.