The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Open accessAbstract
It is still an open challenge to find a biodegradable metallic material exhibiting sufficient mechanical properties and degradation behavior to serve as an arterial stent. In this study, Zn-Mg alloys of 0.002 (Zn-002Mg), 0.005 (Zn-005Mg) and 0.08 wt% Mg (Zn-08Mg) content were cast, extruded and drawn to 0.25 mm diameter, and evaluated as potential biodegradable stent materials. Structural analysis confirmed formation of Mg2Zn11 intermetallic in all three alloys with the average grain size decreasing with increasing Mg content. Tensile testing, fractography analysis and micro hardness measurements showed the best integration of strength, ductility and hardness for the Zn-08Mg alloy. Yield strength, tensile strength, and elongation to failure values of >200–300 MPa, >300–400 MPa, and >30% respectively, were recorded for Zn-08Mg. This metal appears to be the first formulated biodegradable material that satisfies benchmark values desirable for endovascular stenting. Unfortunately, the alloy reveals signs of age hardening and strain rate sensitivity, which need to be addressed before using this metal for stenting. The explants of Zn-08Mg alloy residing in the abdominal aorta of adult male Sprague-Dawley rats for 1.5, 3, 4.5, 6 and 11 months demonstrated similar, yet slightly elevated inflammation and neointimal activation for the alloy relative to what was recently reported for pure zinc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Hansen, M., Anderko, K., & Salzberg, H. W. (1958) · Journal of The Electrochemical Society · doi:10.1149/1.2428700 · Cited by 14,782
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Hall–Petch relation and boundary strengthening
Hansen, N. (2004) · Scripta Materialia · doi:10.1016/j.scriptamat.2004.06.002 · Cited by 3,799
Saris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
Self-citationErbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S. (2007) · Circulation · doi:10.1161/circulationaha.106.658237 · Cited by 839
Vojtěch, D., Kubásek, J., Šerák, J., & Novák, P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.008 · Cited by 708
Predictive Factors of Restenosis After Coronary Stent Placement
Kastrati, A., Schömig, A., Elezi, S., Schühlen, H., Dirschinger, J., Hadamitzky, M., Wehinger, A., Hausleiter, J., Walter, H., & Neumann, F.-J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00334-3 · Cited by 685
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.029 · Cited by 558
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Self-citationDevelopment of biodegradable Zn-1X binary alloys with nutrient alloying elements Mg, Ca and Sr
Li, H. F., Xie, X. H., Zheng, Y. F., Cong, Y., Zhou, F. Y., Qiu, K. J., Wang, X., Chen, S. H., Huang, L., Tian, L., et al. (2015) · Scientific Reports · doi:10.1038/srep10719 · Cited by 515
Vessel Size and Long-Term Outcome After Coronary Stent Placement
Elezi, S., Kastrati, A., Neumann, F.-J., Hadamitzky, M., Dirschinger, J., & Schömig, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1875 · Cited by 484
Daniels, A. U., Chang, M. K. O., Andriano, K. P., & Heller, J. (1990) · Journal of Applied Biomaterials · doi:10.1002/jab.770010109 · Cited by 483
Mostaed, E., Sikora-Jasinska, M., Mostaed, A., Loffredo, S., Demir, A. G., Previtali, B., Mantovani, D., Beanland, R., & Vedani, M. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.03.018 · Cited by 475
Drug‐Eluting Bioabsorbable Magnesium Stent
DI MARIO, C., GRIFFITHS, H., GOKTEKIN, O., PEETERS, N., VERBIST, J., BOSIERS, M., DELOOSE, K., HEUBLEIN, B., ROHDE, R., KASESE, V., et al. (2004) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2004.04081.x · Cited by 428
Kubásek, J., Vojtěch, D., Jablonská, E., Pospíšilová, I., Lipov, J., & Ruml, T. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.08.015 · Cited by 360
Calcium orthophosphate coatings on magnesium and its biodegradable alloys
Dorozhkin, S. V. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.026 · Cited by 332
Degradable metallic biomaterials: Design and development of Fe–Mn alloys for stents
Hermawan, H., Dube, D., & Mantovani, D. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32224 · Cited by 332
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330
Corrosion mechanism of model zinc–magnesium alloys in atmospheric conditions
Prosek, T., Nazarov, A., Bexell, U., Thierry, D., & Serak, J. (2008) · Corrosion Science · doi:10.1016/j.corsci.2008.06.008 · Cited by 321
Li, H., Yang, H., Zheng, Y., Zhou, F., Qiu, K., & Wang, X. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.05.089 · Cited by 296
Gong, H., Wang, K., Strich, R., & Zhou, J. G. (2015) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33341 · Cited by 264
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents
Bowen, P. K., Guillory, R. J., Shearier, E. R., Seitz, J.-M., Drelich, J., Bocks, M., Zhao, F., & Goldman, J. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.07.022 · Cited by 261
Self-citationWillbold, E., Gu, X., Albert, D., Kalla, K., Bobe, K., Brauneis, M., Janning, C., Nellesen, J., Czayka, W., Tillmann, W., et al. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.09.041 · Cited by 254
Biocorrosion behavior of magnesium alloy in different simulated fluids for biomedical application
Yang, L., & Zhang, E. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2009.01.014 · Cited by 250
Comparative in vitro Study on Pure Metals (Fe, Mn, Mg, Zn and W) as Biodegradable Metals
Cheng, J., Liu, B., Wu, Y. H., & Zheng, Y. F. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.019 · Cited by 249
Recent Advances in Biodegradable Metals for Medical Sutures: A Critical Review
Seitz, J., Durisin, M., Goldman, J., & Drelich, J. W. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500189 · Cited by 243
Self-citationLiu, X., Sun, J., Qiu, K., Yang, Y., Pu, Z., Li, L., & Zheng, Y. (2016) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2015.10.116 · Cited by 233
The role of trace minerals in osteoporosis.
Saltman, P. D., & Strause, L. G. (1993) · Journal of the American College of Nutrition · doi:10.1080/07315724.1993.10718327 · Cited by 230
Cytotoxicity evaluation of biodegradable Zn–3Mg alloy toward normal human osteoblast cells
Murni, N. S., Dambatta, M. S., Yeap, S. K., Froemming, G. R. A., & Hermawan, H. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.01.056 · Cited by 218
Zhu, S., Huang, N., Xu, L., Zhang, Y., Liu, H., Sun, H., & Leng, Y. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.12.019 · Cited by 192
Effects of Mg on microstructure and corrosion properties of Zn–Mg alloy
Yao, C., Wang, Z., Tay, S. L., Zhu, T., & Gao, W. (2014) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2014.03.025 · Cited by 183
Shen, C., Liu, X., Fan, B., et al. (2016) · RSC Advances · doi:10.1039/c6ra14300h · Cited by 151
Honoring Leslie A. Geddes - Farewell ...
Valentinuzzi, M. E. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-1 · Cited by 129
Bioresorbable scaffold technologies.
Onuma, Y., Ormiston, J., & Serruys, P. (2011) · Circulation Journal · doi:10.1253/circj.cj-10-1135 · Cited by 122
Chen, Y., Zhao, S., Лю, Б., Chen, M., Mao, J., He, H., Zhao, Y., Huang, N., & Wan, G. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am506741d · Cited by 120
Self-citationFe–Au and Fe–Ag composites as candidates for biodegradable stent materials
Huang, T., Cheng, J. B., Bian, D., & Zheng, Y. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33389 · Cited by 110
Dambatta, M. S., Izman, S., Kurniawan, D., et al. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.06.181 · Cited by 109
In vitro investigation of ultra-pure Zn and its mini-tube as potential bioabsorbable stent material
Liu, X., Sun, J., Yang, Y., et al. (2015) · Materials Letters · doi:10.1016/j.matlet.2015.06.107 · Cited by 107
Microstructure, Mechanical Properties and Fracture Behavior of As-Extruded Zn–Mg Binary Alloys
Wang, L., Ren, Y., Sun, S., et al. (2017) · Acta Metallurgica Sinica (English Letters) · doi:10.1007/s40195-017-0585-4 · Cited by 105
In vitro mechanical and corrosion properties of biodegradable Mg-Ag alloys
Tie, D., Feyerabend, F., Hort, N., Höche, D., Kainer, K. U., Willumeit‐Römer, R., & Müeller, W. D. (2013) · Materials and Corrosion · doi:10.1002/maco.201206903 · Cited by 102
Grabow, N., Bünger, C. M., Schultze, C., Schmohl, K., Martin, D. P., Williams, S. F., Sternberg, K., & Schmitz, K. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9376-9 · Cited by 96
Addition of Zn to the ternary Mg–Ca–Sr alloys significantly improves their antibacterial properties
He, G., Wu, Y., Zhang, Y., Zhu, Y., Liu, Y., Li, N., Li, M., Zheng, G., He, B., Yin, Q., et al. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb01319d · Cited by 90
Rates ofin vivo(arterial) andin vitrobiocorrosion for pure magnesium
Bowen, P. K., Drelich, A. J., Drelich, J. W., & Goldman, J. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35179 · Cited by 88
Self-citationChung, W.-S., Park, C. S., Seung, K. B., Kim, P.-J., Lee, J.-M., Koo, B., Jang, Y., Yang, J.-Y., Yoon, J., Kim, D., et al. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.033 · Cited by 85
A Biodegradable Poly‐l‐lactic Acid Coronary Stent in the Porcine Coronary Artery
Tamai, H., Igaki, K., Tsuji, T., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Motohara, S., Uehata, H., et al. (1999) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.1999.tb00673.x · Cited by 76
Factors that affect mass transport from drug eluting stents into the artery wall
O’Connell, B. M., McGloughlin, T. M., & Walsh, M. T. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-15 · Cited by 52
Bünger, C. M., Grabow, N., Sternberg, K., Goosmann, M., Schmitz, K., Kreutzer, H. J., İnce, H., Kische, S., Nienaber, C. A., Martin, D. P., et al. (2007) · Journal of Endovascular Therapy · doi:10.1177/152660280701400518 · Cited by 52
Zinc intervention on macrophages and lymphocytes response
Lastra, M. D., Pastelin‐Palacios, R., Camacho, A., Monroy, B., & Aguilar, A. E. (2001) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/s0946-672x(01)80019-5 · Cited by 39
Liu, Y., Bian, D., Wu, Y., Li, N., Qiu, K., Zheng, Y., & Han, Y. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.05.050 · Cited by 34
Thermodynamic description of Cu–Mg–Ni and Cu–Mg–Zn systems
Miettinen, J. (2008) · Calphad · doi:10.1016/j.calphad.2008.03.005 · Cited by 34
Cited by
Alloying design of biodegradable zinc as promising bone implants for load-bearing applications
Yang, H., Jia, B., Zhang, Z., Qu, X., Li, G., Lin, W., Zhu, D., Dai, K., & Zheng, Y. (2020) · Nature Communications · doi:10.1038/s41467-019-14153-7 · Cited by 756
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Self-citationFundamental Theory of Biodegradable Metals—Definition, Criteria, and Design
Liu, Y., Zheng, Y., Chen, X., Yang, J., Pan, H., Chen, D., Wang, L., Zhang, J., Zhu, D., Wu, S., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805402 · Cited by 519
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Metadata
- Authors
- Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2018-03
- Volume
- 84
- Pages
- 67-79
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2768779222
- Cited by
- 271
- References
- 57
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.