CoChat

Evaluation of nano hydrogel composite based on gelatin/HA/CS suffused with Asiatic acid/ZnO and CuO nanoparticles for second degree burns

A.V., Thanusha, Dinda, Amit Kumar, Koul, Veena · 2018 · Materials Science and Engineering: C
Cited by 111

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In the present work, a hydrogel platform composed of biopolymer gelatin, and glycosaminoglycan's (Hyaluronic acid and Chondroitin sulfate) incorporated with Asiatic acid (a triterpenoid) and nanoparticles (Zinc oxide and Copper oxide) has been designed and developed to find out the efficacy of healing in second degree burn wounds in Wistar rats. The developed hydrogel composite has been characterized by physico-chemical methods such as; SEM, swelling, mechanical strength, degradation and drug release kinetics. Results showed that the morphology of composite scaffolds are porous with maximum water uptake capacity of 1068% and possessed tensile strength of ~0.196 MPa. Anti-microbial evaluation depicted increase in zone of inhibition with hydrogel containing gelatin + ZnO (5.3 ± 0.2 mm in E. coli and 4.9 ± 0.6 mm in S. aureus) and gelatin + CuO (4.8 ± 0.7 mm in E. coli, 3.8 ± 0.3 mm in S. aureus) in comparison to hydrogel composite scaffold. In-vitro cytocompatibility of developed hydrogel composite was assessed in terms of MTT and DNA quantification on L929 fibroblast cells. In-vivo studies for the composite scaffolds were evaluated on Wistar rats after second degree burn wounds were induced and studied for 28 days which showed the significant wound healing activity in comparison to the control (NeuSkin™ and Cotton guaze) in terms of DNA, total protein, hexosamine and hydroxyproline content. Histopathology studies showed the significant progress in re-epithelization, collagen fibers arrangement and angiogenesis in comparison to control. Additionally, a decrease of TNF-α and increase of MMP-2 expression on day 7 of animal experiment support healing. Furthermore, no toxicity was seen with the developed scaffolds suggesting their suitability to use as a wound dressing in second degree burns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.msec.2018.03.034

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 111

Metadata

Authors
A.V., T., Dinda, A. K., & Koul, V.
Venue
Materials Science and Engineering: C
Publisher
Elsevier BV
Published
2018-08
Volume
89
Pages
378-386
ISSN
0928-4931 (ISSN-L)
OpenAlex
W2796703386
Cited by
111
References
5
FWCI
7.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of nano hydrogel composite based on gelatin/HA/CS suffused with Asiatic acid/ZnO and CuO nanoparticles for second degree burns. https://app.cochat.ai/papers/10.1016/j.msec.2018.03.034
The paper
A.V., T., Dinda, A. K., & Koul, V. (2018). Evaluation of nano hydrogel composite based on gelatin/HA/CS suffused with Asiatic acid/ZnO and CuO nanoparticles for second degree burns. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2018.03.034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.