Abstract

The increasing employment of non-degradable polymers based single-use, disposable medical devices have led to huge environmental pressure. Replacement of non-degradable polymers with biodegradable alternatives could be one solution. Since terminal sterilization is a necessary procedure for medical devices to eliminate infections, in this paper, the modifications of sterilization on the transparency, yellow index, dimensional stability and mechanical properties of commercial biodegradable poly(lactic acid) (PLA), poly(butylenes adipate-co-terephthalate) (PBAT) and their blends were investigated. The samples were prepared by compression molding and exposed to four sterilization treatments including ethylene oxide gas (EtO), saturated steam (SS), electron beam (EB), and hydrogen peroxide gas plasma (HPGP). It is concluded that EB can be applied for the sterilization of all the materials investigated, while SS and EtO are not recommended for PLA, and HPGP is not for PBAT and PLA/PBAT blends. This study demonstrates that, when a suitable sterilization process is chosen, PLA has potential to be used for transparent medical devices such as the barrel of syringes or microfluidic chips, while PBAT and PLA/PBAT blends for other non-transparent medical packaging applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.msec.2019.110041

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 91

Metadata

Authors
Zhao, Y., Zhu, B., Wang, Y., Liu, C., & Shen, C.
Venue
Materials Science and Engineering: C
Publisher
Elsevier BV
Published
2019-12
Volume
105
Pages
110041
ISSN
0928-4931 (ISSN-L)
OpenAlex
W2966707638
Cited by
91
References
6
FWCI
3.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of different sterilization methods on the properties of commercial biodegradable polyesters for single-use, disposable medical devices. https://app.cochat.ai/papers/10.1016/j.msec.2019.110041
The paper
Zhao, Y., Zhu, B., Wang, Y., Liu, C., & Shen, C. (2019). Effect of different sterilization methods on the properties of commercial biodegradable polyesters for single-use, disposable medical devices. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2019.110041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.