Microfluidic devices for modeling cell–cell and particle–cell interactions in the microvasculature
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Cell-fluid and cell-cell interactions are critical components of many physiological and pathological conditions in the microvasculature. Similarly, particle-cell interactions play an important role in targeted delivery of therapeutics to tissue. Development of in vitro fluidic devices to mimic these microcirculatory processes has been a critical step forward in our understanding of the inflammatory process, development of nano-particulate drug carriers, and developing realistic in vitro models of the microvasculature and its surrounding tissue. However, widely used parallel plate flow based devices and assays have a number of important limitations for studying the physiological conditions in vivo. In addition, these devices are resource hungry and time consuming for performing various assays. Recently developed, more realistic, microfluidic based devices have been able to overcome many of these limitations. In this review, an overview of the fluidic devices and their use in studying the effects of shear forces on cell-cell and cell-particle interactions is presented. In addition, use of mathematical models and Computational Fluid Dynamics (CFD) based models for interpreting the complex flow patterns in the microvasculature are highlighted. Finally, the potential of 3D microfluidic devices and imaging for better representing in vivo conditions under which cell-cell and cell-particle interactions take place are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Getting to the site of inflammation: the leukocyte adhesion cascade updated
Ley, K., Laudanna, C., Cybulsky, M. I., & Nourshargh, S. (2007) · Nature Reviews Immunology · doi:10.1038/nri2156 · Cited by 4,354 · cited 2×
“These cell-cell interactions include the leukocyte adhesion cascade (Ley et al., 2007), which includes leukocyte rolling, adhesion to the endothelium and subsequent migration into the tissue, platelet adhesion (Jackson et al., 2009), and tumor cell adhesion (Zigler et al., 2010).”
BackgroundSelectins and their ligands: Current concepts and controversies
Kansas, G. (1996) · Blood · doi:10.1182/blood.v88.9.3259.bloodjournal8893259 · Cited by 1,415
Cited by
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
SyM-BBB: a microfluidic blood brain barrier model
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Mills, I. R., Sidoryk-Wegrzynowicz, M., Aschner, M., & Pant, K. (2013) · Lab on a Chip · doi:10.1039/c2lc41208j · Cited by 339
Self-citationOrgans-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Tang, Y., Soroush, F., Sheffield, J. B., Wang, B., Prabhakarpandian, B., & Kiani, M. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-09815-9 · Cited by 102
Self-citationSynthetic tumor networks for screening drug delivery systems
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Garson, C. J., Mills, I. R., Matar, M. M., Fewell, J. G., & Pant, K. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.01.018 · Cited by 57
Self-citationRapid Assessment of Nanoparticle Extravasation in a Microfluidic Tumor Model
Vu, M. N., Rajasekhar, P., Poole, D. P., Khor, S. Y., Truong, N. P., Nowell, C. J., Quinn, J. F., Whittaker, M., Veldhuis, N. A., & Davis, T. P. (2019) · ACS Applied Nano Materials · doi:10.1021/acsanm.8b02056 · Cited by 52
Refining in vitro models for nanomaterial exposure to cells and tissues
Guggenheim, E. J., Milani, S., Röttgermann, P. J. F., Dusinska, M., Saout, C., Salvati, A., Rädler, J. O., & Lynch, I. (2018) · NanoImpact · doi:10.1016/j.impact.2018.02.008 · Cited by 36
Metadata
- Authors
- Prabhakarpandian, B., Shen, M.-C., Pant, K., & Kiani, M. F.
- Venue
- Microvascular Research
- Publisher
- Elsevier BV
- Published
- 2011-11
- Volume
- 82
- Issue
- 3
- Pages
- 210-220
- ISSN
- 0026-2862 (ISSN-L)
- OpenAlex
- W2095921273
- Cited by
- 89
- References
- 2
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.