Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 404

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Nanofluids effects on the evaporation rate in a solar still equipped with a heat exchanger

Mahian, Omid, Kianifar, Ali, Heris, Saeed Zeinali, Wen, Dongsheng, Sahin, Ahmet Z., Wongwises, Somchai·2017·Nano Energy

Abstract

Abstract In this paper, the performance of a solar still equipped with a heat exchanger using nanofluids has been studied both experimentally and theoretically through three key parameters, i.e., freshwater yield, energy efficiency and exergy efficiency. First, experiments are performed on a set-up, which is mainly composed of two flat plate solar collectors connected in series, and a solar still equipped with a heat exchanger. After heated in the collectors, the nanofluid enters the heat exchanger installed in the solar still basin to exchange heat with brackish water. The research question is to know how much the effect of nanofluids on the evaporation rate inside the solar desalination system is. The experiments are conducted for different nanoparticle volume fractions, two sizes of nanoparticles (7 and 40 nm), two depths of water in the solar still basin (4 and 8 cm), and three mass flow rates of nanofluids during various weather conditions. It is found that the weather conditions (mainly the sun radiation intensity) have a dominant influence on the solar still performance. To discover the effects of nanofluids, a mathematical model is developed and validated by experimental data at given weather conditions. The results reveal that using the heat exchanger at temperatures lower than 60 °C is not advantageous and the corresponding yield is smaller than that of solar still without the heat exchanger; although in such a case, using nanofluids as the working fluid in the heat exchanger can enhance the performance indices about 10%. At higher temperatures (e.g. 70 °C), the use of heat exchanger is beneficial; however, using nanofluids instead of water can augment the performance indices marginally i.e. just around 1%. In addition, it is found that in high temperatures using SiO 2 /water nanofluids, which have a lower effective thermal conductivity than that of Cu/water nanofluids, provides higher performance indices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2017.04.025

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 404

Metadata

Authors
Mahian, O., Kianifar, A., Heris, S. Z., Wen, D., Sahin, A. Z., & Wongwises, S.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2017-06
Volume
36
Pages
134-155
ISSN
2211-2855 (ISSN-L)
OpenAlex
W2606904263
Cited by
404
References
2
FWCI
15.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nanofluids effects on the evaporation rate in a solar still equipped with a heat exchanger. https://app.cochat.ai/papers/10.1016/j.nanoen.2017.04.025
The paper
Mahian, O., Kianifar, A., Heris, S. Z., Wen, D., Sahin, A. Z., & Wongwises, S. (2017). Nanofluids effects on the evaporation rate in a solar still equipped with a heat exchanger. Nano Energy. https://doi.org/10.1016/j.nanoen.2017.04.025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.