Hierarchical elastomer tuned self-powered pressure sensor for wearable multifunctional cardiovascular electronics
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Abstract Wearable pressure sensors, as essential components of flexible wearable electronics, may play important roles in early diagnosis and mortality prevention for cardiovascular healthcare. However, traditional self-powered pressure sensors can hardly obtain both high sensitivity and wide pressure range, which makes perceiving both cardiac and vascular signals in a wearable self-powered way challenging as these physiological signals not only have imperceptible changes but also span a broad pressure range. Here, we develop a flexible hierarchical elastomer tuned self-powered pressure sensor, which achieves both high-sensitivity and wide pressure range, showing a high sensitivity of 7.989 V kPa−1 and wide pressure range of 0.1–60 kPa simultaneously. Fast response (40 ms) and high signal noise ratio (38 db) with good stability are also achieved. We demonstrate that the self-powered pressure sensor can not only sensitively monitor pulse, artery and heart condition but also monitor the wide range blood pressure, which satisfies the diverse needs of wearable cardiovascular healthcare. As most of the pressure related to human interface is less than 50 kPa, we envision the sensor holds great potential in wearable electronics, mobile healthcare and human-machine interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Global atlas on cardiovascular disease prevention and control.
Mendis, S., Puska, P., & Norrving, B. G. (2011) · Virtual Defense Library (Ministerio de Defensa) · Cited by 3,515
Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn404614z · Cited by 3,058
Heart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820
The Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,087
On Maxwell's displacement current for energy and sensors: the origin of nanogenerators
Wang, Z. L. (2017) · Materials Today · doi:10.1016/j.mattod.2016.12.001 · Cited by 2,083
Theoretical study of contact-mode triboelectric nanogenerators as an effective power source
Niu, S., Wang, S., Lin, L., Liu, Y., Zhou, Y. S., Hu, Y., & Wang, Z. L. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42571a · Cited by 1,956
Cited by
Li, X., He, L., Li, Y., Chao, M., Li, M., Wan, P., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.1c01751 · Cited by 473
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Self-citationChao, M., He, L., Gong, M., Li, N., Li, X., Peng, L., Shi, F., Zhang, L., & Wan, P. (2021) · ACS Nano · doi:10.1021/acsnano.1c00472 · Cited by 387
Ambulatory Cardiovascular Monitoring Via a Machine‐Learning‐Assisted Textile Triboelectric Sensor
Fang, Y., Zou, Y., Xu, J., Chen, G., Zhou, Y., Deng, W., Zhao, X., Roustaei, M., Hsiai, T. K., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202104178 · Cited by 380
Soft fibers with magnetoelasticity for wearable electronics
Zhao, X., Zhou, Y., Xu, J., Chen, G., Fang, Y., Tat, T., Xiao, X., Song, Y., Li, S., & Chen, J. (2021) · Nature Communications · doi:10.1038/s41467-021-27066-1 · Cited by 361
Wearable triboelectric nanogenerators for biomechanical energy harvesting
Zou, Y., Raveendran, V., & Chen, J. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105303 · Cited by 351
Li, M., Zhang, Y., Lian, L., Liu, K., Lu, M., Chen, Y., Zhang, L., Zhang, X., & Wan, P. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202208141 · Cited by 329
Progress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
Roles of MXene in Pressure Sensing: Preparation, Composite Structure Design, and Mechanism
Lei, D., Liu, N., Su, T., Zhang, Q., Wang, L., Ren, Z., & Gao, Y. (2022) · Advanced Materials · doi:10.1002/adma.202110608 · Cited by 253
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Ji, B., Zhou, Q., Hu, B., Zhong, J., Zhou, J., & Zhou, B. (2021) · Advanced Materials · doi:10.1002/adma.202100859 · Cited by 232
Self-citationYang, P., Shi, Y., Li, S., Tao, X., Liu, Z., Wang, X., Wang, Z. L., & Chen, X. (2022) · ACS Nano · doi:10.1021/acsnano.1c11321 · Cited by 195
Recent progress in self‐powered multifunctional e‐skin for advanced applications
Chen, Y., Gao, Z., Zhang, F., Wen, Z., & Sun, X. (2022) · Exploration · doi:10.1002/exp.20210112 · Cited by 186
Advances in self-powered triboelectric pressure sensors
Lei, H., Chen, Y., Gao, Z., Wen, Z., & Sun, X. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta03505c · Cited by 181
Chao, M., Di, P., Yuan, Y., Xu, Y., Zhang, L., & Wan, P. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108201 · Cited by 177
Textile Triboelectric Nanogenerators for Wearable Pulse Wave Monitoring
Chen, G., Au, C., & Chen, J. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.12.011 · Cited by 170
Cui, X., Huang, F., Zhang, X., Song, P., Zheng, H., Chevali, V., Wang, H., & Xu, Z. (2022) · iScience · doi:10.1016/j.isci.2022.104148 · Cited by 170
Self-citationWen, F., He, T., Liu, H., Chen, H.-Y., Zhang, T., & Lee, C. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105155 · Cited by 158
Metadata
- Authors
- Chen, S., Wu, N., Lin, S., Duan, J., Xu, Z., Pan, Y., Zhang, H., Xu, Z., Huang, L., Hu, B., & Zhou, J.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 70
- Pages
- 104460
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3000642422
- Cited by
- 196
- References
- 52
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.