The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Highly stretchable and self-healing strain sensors for motion detection in wireless human-machine interface
Abstract
Abstract The highly stretchable, flexible and self-healing strain sensor is considered as a promising wearable device for motion detection in fields such as robotics and human-machine interface. Herein, a strain sensor with high stretchability and sensitivity is designed and fabricated based on the poly(acrylamide) (PAAm) hydrogel. The ionic conductive PAAm hydrogel shows an excellent self-healing property with fast electrical self-healing speed (within 1.8 s) and high self-healing efficiency (99%). The PAAm hydrogel based strain sensor exhibits excellent performance with large stretchability (>900%), high sensitivity (with maximum gauge factor of 6.44), fast response time (~150 ms), and good cycling durability (>3000 cycles). As the wearable device, the strain sensor can detect various human motions and is able to transmit the data to the smart phone combined with a readout and wireless system. Furthermore, a smart glove was fabricated by coupling multiple strain sensors and the corresponding circuit. The smart glove is capable of expressing and recognizing American Sign Language and can be used to control a robotic hand wirelessly through the hand gestures. Thus, the highly stretchable, self-healing hydrogel-based strain sensor shows a potential application for the human-machine interface, personal healthcare and sports training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
A bioinspired flexible organic artificial afferent nerve
Kim, Y., Chortos, A., Xu, W., Liu, Y., Oh, J. Y., Son, D., Kang, J., Foudeh, A. M., Zhu, C., Lee, Y., et al. (2018) · Science · doi:10.1126/science.aao0098 · Cited by 1,466
Learning the signatures of the human grasp using a scalable tactile glove
Sundaram, S., Kellnhofer, P., Li, Y., Zhu, J.-Y., Torralba, A., & Matusik, W. (2019) · Nature · doi:10.1038/s41586-019-1234-z · Cited by 1,162
Cai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Self-citationPark, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Instant tough bonding of hydrogels for soft machines and electronics
Wirthl, D., Pichler, R., Drack, M., Kettlguber, G., Moser, R., Gerstmayr, R., Hartmann, F., Bradt, E., Kaltseis, R., Siket, C. M., et al. (2017) · Science Advances · doi:10.1126/sciadv.1700053 · Cited by 471
Cited by
High‐Stretchability, Ultralow‐Hysteresis ConductingPolymer Hydrogel Strain Sensors for Soft Machines
Shen, Z., Zhang, Z., Zhang, N., Li, J., Zhou, P., Hu, F., Rong, Y., Lu, B., & Gu, G. (2022) · Advanced Materials · doi:10.1002/adma.202203650 · Cited by 574
Yao, X., Zhang, S., Qian, L., Wei, N., Nica, V., Coseri, S., & Han, F. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204565 · Cited by 487
Liu, X., Miao, J., Fan, Q., Zhang, W., Zuo, X., Tian, M., Zhu, S., Zhang, X., & Qu, L. (2022) · Advanced Fiber Materials · doi:10.1007/s42765-021-00126-3 · Cited by 350
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Mechanically Durable Memristor Arrays Based on a Discrete Structure Design
Wang, T., Cui, Z., Liu, Y., Lu, D., Wang, M., Wan, C., Leow, W. R., Wang, C., Pan, L., Cao, X., et al. (2022) · Advanced Materials · doi:10.1002/adma.202106212 · Cited by 42
Metadata
- Authors
- Hang, C.-Z., Zhao, X.-F., Xi, S.-Y., Shang, Y.-H., Yuan, K.-P., Yang, F., Wang, Q.-G., Wang, J.-C., Zhang, D. W., & Lu, H.-L.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 76
- Pages
- 105064
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3037296202
- Cited by
- 187
- References
- 7
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly stretchable and self-healing strain sensors for motion detection in wireless human-machine interface. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.105064
- The paper
- Hang, C.-Z., Zhao, X.-F., Xi, S.-Y., Shang, Y.-H., Yuan, K.-P., Yang, F., Wang, Q.-G., Wang, J.-C., Zhang, D. W., & Lu, H.-L. (2020). Highly stretchable and self-healing strain sensors for motion detection in wireless human-machine interface. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.105064
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.