Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Wearable MXene nanocomposites-based strain sensor with tile-like stacked hierarchical microstructure for broad-range ultrasensitive sensing

Chao, Mingyuan, Wang, Yonggang, Ma, Di, Wu, Xiaoxuan, Zhang, Weixia, Zhang, Liqun, Wan, Pengbo·2020·Nano Energy

Abstract

Abstract Flexible wearable strain sensors with high sensitivity, broad sensing range, large stretchability and low strain detectability have drawn tremendous interest for various applications in electronic skins, human motion detection, and medical diagnosis. However, conventional strain sensors usually showed narrow sensing range, low sensitivity, and complicated fabrication process, which restrict their potential applications in precise detection of vital healthcare signals. In this work, we report the fabrication of a flexible wearable strain sensor by using the MXene/polyaniline fiber (PANIF) (MXene/PANIF) nanocomposites sensing layer with tile-like stacked hierarchical microstructures, inspired from the overlapped rooftop tiles of the ancient palace. The MXene/PANIF nanocomposites sensing layer with tile-like stacked hierarchical microstructures is prepared via spreading MXene and PANIF layer on the elastic rubber substrate respectively. The assembled strain sensor can be used to detect broad-range (up to 80% strain) human motion with ultralow detection limit (0.1538% strain), high sensitivity (up to 2369.1 for the gauge factor (GF)), and excellent reproducibility and stability. Furthermore, the strain sensor could be coupled to a wireless transmitter for wirelessly human motion monitoring. Therefore, the wearable MXene nanocomposites-based strain sensor is a promising and attractive future electronic device for various real-time human motion detection, personal healthcare monitoring, and clinical diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2020.105187

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 233

Metadata

Authors
Chao, M., Wang, Y., Ma, D., Wu, X., Zhang, W., Zhang, L., & Wan, P.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2020-12
Volume
78
Pages
105187
ISSN
2211-2855 (ISSN-L)
OpenAlex
W3043968868
Cited by
233
References
7
FWCI
9.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable MXene nanocomposites-based strain sensor with tile-like stacked hierarchical microstructure for broad-range ultrasensitive sensing. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.105187
The paper
Chao, M., Wang, Y., Ma, D., Wu, X., Zhang, W., Zhang, L., & Wan, P. (2020). Wearable MXene nanocomposites-based strain sensor with tile-like stacked hierarchical microstructure for broad-range ultrasensitive sensing. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.105187

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.