The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Discrepancies between BOLD and flow dynamics in primary and supplementary motor areas: application of the balloon model to the interpretation of BOLD transients
Open accessAbstract
The blood-oxygen-level-dependent (BOLD) signal measured in the brain with functional magnetic resonance imaging (fMRI) during an activation experiment often exhibits pronounced transients at the beginning and end of the stimulus. Such transients could be a reflection of transients in the underlying neural activity, or they could result from transients in cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), or cerebral blood volume (CBV). These transients were investigated using an arterial spin labeling (ASL) method that allows simultaneous measurements of BOLD and CBF responses. Responses to a finger-tapping task (40-s stimulus, 80-s rest) were measured in primary motor area (M1) and supplementary motor area (SMA) in five healthy volunteers. In SMA, the average BOLD response was pronounced near the beginning and end of the stimulus, while in M1, the BOLD response was nearly flat. However, CBF responses in the two regions were rather similar, and did not exhibit the same transient features as the BOLD response in SMA. Because this suggests a hemodynamic rather than a neural origin for the transients of the BOLD response in SMA, we used a generalization of the balloon model to test the degree of hemodynamic transients required to produce the measured curves. Both data sets could be approximated with modest differences in the shapes of the CMRO2 and CBV responses. This study illustrates the utility and the limitations of using theoretical models combined with ASL techniques to understand the dynamics of the BOLD response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Linear Systems Analysis of Functional Magnetic Resonance Imaging in Human V1
Boynton, G. M., Engel, S. A., Glover, G. H., & Heeger, D. J. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-13-04207.1996 · Cited by 2,314
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Self-citationA general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Self-citationCalibrated functional MRI: Mapping the dynamics of oxidative metabolism
Davis, T. L., Kwong, K. K., Weisskoff, R. M., & Rosen, B. R. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1834 · Cited by 1,052
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Self-citationWong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Self-citationDynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation
Mandeville, J. B., Marota, J. J. A., Kosofsky, B. E., Keltner, J. R., Weissleder, R., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390415 · Cited by 549
Evidence of a Cerebrovascular Postarteriole Windkessel with Delayed Compliance
Mandeville, J. B., Marota, J. J. A., Ayata, C., Zaharchuk, G., Moskowitz, M. A., Rosen, B. R., & Weisskoff, R. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199906000-00012 · Cited by 520
Cited by
Modeling the hemodynamic response to brain activation
Buxton, R. B., Uludağ, K., Dubowitz, D. J., & Liu, T. T. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.013 · Cited by 1,229
Self-citationA quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
Comparing hemodynamic models with DCM
Stephan, K. E., Weiskopf, N., Drysdale, P. M., Robinson, P. A., & Friston, K. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.040 · Cited by 441
Metadata
- Authors
- Obata, T., Liu, T. T., Miller, K. L., Luh, W.-M., Wong, E. C., Frank, L. R., & Buxton, R. B.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 21
- Issue
- 1
- Pages
- 144-153
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2092658543
- Cited by
- 252
- References
- 22
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrepancies between BOLD and flow dynamics in primary and supplementary motor areas: application of the balloon model to the interpretation of BOLD transients. https://app.cochat.ai/papers/10.1016/j.neuroimage.2003.08.040
- The paper
- Obata, T., Liu, T. T., Miller, K. L., Luh, W.-M., Wong, E. C., Frank, L. R., & Buxton, R. B. (2004). Discrepancies between BOLD and flow dynamics in primary and supplementary motor areas: application of the balloon model to the interpretation of BOLD transients. NeuroImage. https://doi.org/10.1016/j.neuroimage.2003.08.040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.