The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
Open accessAbstract
Diffusion tensor imaging (DTI) is used to study tissue composition and architecture in vivo. To increase the signal to noise ratio (SNR) of DTI contrasts, studies typically use more than the minimum of 6 diffusion weighting (DW) directions or acquire repeated observations of the same set of DW directions. Simulation-based studies have sought to optimize DTI acquisitions and suggest that increasing the directional resolution of a DTI dataset (i.e., the number of distinct directions) is preferable to repeating observations, in an equal scan time comparison. However, it is not always clear how to translate these recommendations into practice when considering physiological noise and scanner stability. Furthermore, the effect of different DW schemes on in vivo DTI findings is not fully understood. This study characterizes how the makeup of a DW scheme, in terms of the number of directions, impacts the precision and accuracy of in vivo fractional anisotropy (FA), mean diffusivity (MD), and principal eigenvector (PEV) findings. Orientation dependence of DTI reliability is demonstrated in vivo and a principled theoretical framework is provided to support and interpret findings with simulation results. As long as sampling orientations are well balanced, differences in DTI contrasts due to different DW schemes are shown to be small relative to intra-session variability. These differences are accentuated at low SNR, while minimized at high SNR. This result suggests that typical clinical studies, which use similar protocols but different well-balanced DW schemes, are readily comparable within the experimental precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Self-citationPractical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Practical statistics for medical research
King, M. (1992) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(92)90046-5 · Cited by 1,659
Permutation Tests: A Practical Guide to Resampling Methods for Testing Hypotheses
Niknian, M. (1995) · Technometrics · doi:10.1080/00401706.1995.10484341 · Cited by 1,462
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Jones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
RESTORE: Robust estimation of tensors by outlier rejection
Chang, L., Jones, D. K., & Pierpaoli, C. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20426 · Cited by 606
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Characterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510
Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI
Jones, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10331 · Cited by 370
Comparison of gradient encoding schemes for diffusion‐tensor MRI
Hasan, K. M., Parker, D. L., & Alexander, A. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1107 · Cited by 309
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Skare, S., Hedehus, M., Moseley, M. E., & Li, T.-Q. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2209 · Cited by 297
Koay, C. G., Chang, L.-C., Carew, J. D., Pierpaoli, C., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.06.020 · Cited by 243
Optimal imaging parameters for fiber-orientation estimation in diffusion MRI
Alexander, D. C., & Barker, G. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.008 · Cited by 232
A study of rotationally invariant and symmetric indices of diffusion anisotropy
Papadakis, N. G., Xing, D., Houston, G. C., Smith, J. M., Smith, M. I., James, M. F., Parsons, A. A., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00029-6 · Cited by 179
Ni, H., Kavcic, V., Zhu, T., EKHOLM, S. E., & Zhong, J. (2006) · PubMed · Cited by 177
Anisotropic noise propagation in diffusion tensor MRI sampling schemes
Batchelor, P. G., Atkinson, D., Hill, D., Calamante, F., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10491 · Cited by 139
Hasan, K. M., Alexander, A. L., & Narayana, P. A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10682 · Cited by 116
High‐resolution isotropic 3D diffusion tensor imaging of the human brain
Golay, X., Jiang, H., van Zijl, P. C. M., & Mori, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10143 · Cited by 66
Self-citationVoss, H. U., Watts, R., Uluğ, A. M., & Ballon, D. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.007 · Cited by 56
Cited by
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Self-citationNiogi, S. N., Mukherjee, P., Ghajar, J., Johnson, C., Kolster, R. A., Sarkar, R., Lee, H., Meeker, M., Zimmerman, R. D., Manley, G. T., et al. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0970 · Cited by 590
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
A qualitative and quantitative review of diffusion tensor imaging studies in reading and dyslexia
Vandermosten, M., Boets, B., Wouters, J., & Ghesquière, P. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.04.002 · Cited by 358
Metadata
- Authors
- Landman, B. A., Farrell, J. A. D., Jones, C. K., Smith, S. A., Prince, J. L., & Mori, S.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2007-07
- Volume
- 36
- Issue
- 4
- Pages
- 1123-1138
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2059685157
- Cited by
- 285
- References
- 26
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.