The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Physiological noise modelling for spinal functional magnetic resonance imaging studies
Open accessAbstract
Spinal cord functional imaging allows assessment of activity in primary synaptic connections made by sensory neurons relaying information about the state of the body. However, reported human data based on gradient-echo techniques have been largely inconsistent, with no clear patterns of activation emerging. One reason for this variability is the influence of physiological noise, which is typically not corrected for. By acquiring single-slice resting data from the spinal cord with a conventional gradient-echo EPI pulse sequence at TR=200 ms (critically sampled) and TR=3 s (under-sampled), we have characterised various sources of physiological noise. In 8 healthy subjects, the presence of physiologically dependent signal was explored using probabilistic independent component analysis (PICA). Based on the insights provided by PICA, we defined a new physiological noise model (PNM) based on retrospective image correction (RETROICOR), which uses independent physiological measurements taken from the subject to model sources of noise. Statistical significance of individual components included in the PNM was assessed by F-tests, which demonstrated that the optimal PNM included cardiac, respiratory, interaction and low-frequency regressors. In a group of 10 healthy subjects, activation data were acquired from the cervical spinal region (T1 to C5) during painful thermal stimulation of the right and left hands. The improvement obtained when using a PNM in estimating spinal cord activation was reflected in a reduction of false-positive activation (active voxels in the CSF space surrounding the cord), when compared to conventional GLM modelling without a PNM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Self-citationBrain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Thresholding of statistical maps in functional neuroimaging using the false discovery rate
Genovese, C. R., Lazar, N. A., & Nichols, T. (2002) · NeuroImage · doi:10.1006/nimg.2001.1037 · Cited by 4,923
Neuronal plasticity: Increasing the gain in pain
Woolf, C. J., & Salter, M. W. (2000) · Science · doi:10.1126/science.288.5472.1765 · Cited by 3,781
Wise, R. G., Ide, K., Poulin, M. J., & Tracey, I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.025 · Cited by 664
Self-citationAnticipatory brainstem activity predicts neural processing of pain in humans
Fairhurst, M., Wiech, K., Dunckley, P., & Tracey, I. (2007) · Pain · doi:10.1016/j.pain.2006.09.001 · Cited by 231
Self-citationPhysiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
Cited by
Function in the human connectome: task-fMRI and individual differences in behavior
Barch, D. M., Burgess, G. C., Harms, M. P., Petersen, S. E., Schlaggar, B. L., Corbetta, M., Glasser, M. F., Curtiss, S., Dixit, S., Feldt, C., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.033 · Cited by 1,529
Rowald, A., Komi, S., Demesmaeker, R., Baaklini, E., Hernandez-Charpak, S. D., Paoles, E., Montanaro, H., Cassara, A., Becce, F., Lloyd, B., et al. (2022) · Nature Medicine · doi:10.1038/s41591-021-01663-5 · Cited by 455
The PhysIO Toolbox for Modeling Physiological Noise in fMRI Data
Kasper, L., Bollmann, S., Diaconescu, A. O., Hutton, C., Heinzle, J., Iglesias, S., Hauser, T. U., Sebold, M., Manjaly, Z.-M., Pruessmann, K. P., et al. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.10.019 · Cited by 409
Neuroimaging of the periaqueductal gray: State of the field
Linnman, C., Moulton, E. A., Barmettler, G., Becerra, L., & Borsook, D. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.095 · Cited by 393
The current state-of-the-art of spinal cord imaging: Methods
Stroman, P. W., Wheeler-Kingshott, C., Bacon, M., Schwab, J. M., Bosma, R., Brooks, J., Cadotte, D., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.124 · Cited by 334
Self-citation
Metadata
- Authors
- Brooks, J. C. W., Beckmann, C. F., Miller, K. L., Wise, R. G., Porro, C. A., Tracey, I., & Jenkinson, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2008-01-15
- Volume
- 39
- Issue
- 2
- Pages
- 680-692
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2129436894
- Cited by
- 242
- References
- 7
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiological noise modelling for spinal functional magnetic resonance imaging studies. https://app.cochat.ai/papers/10.1016/j.neuroimage.2007.09.018
- The paper
- Brooks, J. C. W., Beckmann, C. F., Miller, K. L., Wise, R. G., Porro, C. A., Tracey, I., & Jenkinson, M. (2008). Physiological noise modelling for spinal functional magnetic resonance imaging studies. NeuroImage. https://doi.org/10.1016/j.neuroimage.2007.09.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.