Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coils
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Measures of structural brain change based on longitudinal MR imaging are increasingly important but can be degraded by intensity non-uniformity. This non-uniformity can be more pronounced at higher field strengths, or when using multichannel receiver coils. We assessed the ability of the non-parametric non-uniform intensity normalization (N3) technique to correct non-uniformity in 72 volumetric brain MR scans from the preparatory phase of the Alzheimer's Disease Neuroimaging Initiative (ADNI). Normal elderly subjects (n=18) were scanned on different 3-T scanners with a multichannel phased array receiver coil at baseline, using magnetization prepared rapid gradient echo (MP-RAGE) and spoiled gradient echo (SPGR) pulse sequences, and again 2 weeks later. When applying N3, we used five brain masks of varying accuracy and four spline smoothing distances (d=50, 100, 150 and 200 mm) to ascertain which combination of parameters optimally reduces the non-uniformity. We used the normalized white matter intensity variance (standard deviation/mean) to ascertain quantitatively the correction for a single scan; we used the variance of the normalized difference image to assess quantitatively the consistency of the correction over time from registered scan pairs. Our results showed statistically significant (p<0.01) improvement in uniformity for individual scans and reduction in the normalized difference image variance when using masks that identified distinct brain tissue classes, and when using smaller spline smoothing distances (e.g., 50-100 mm) for both MP-RAGE and SPGR pulse sequences. These optimized settings may assist future large-scale studies where 3-T scanners and phased array receiver coils are used, such as ADNI, so that intensity non-uniformity does not influence the power of MR imaging to detect disease progression and the factors that influence it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“Non-parametric non-uniform intensity normalization (N3) (Sled et al., 1998) is a nonuniformity correction technique that finds a multiplicative field that maximizes the frequency content of the intensity distribution of the corrected scan.”
BackgroundMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“For both masks derived from the 6-dof and 12-dof template registration techniques, we used an entropy-based measure (NMI) as the cost function for the registration, which should be largely independent of any non-uniformity present in the scan (Maes et al., 1997).”
MethodComparison of different MRI brain atrophy rate measures with clinical disease progression in AD
Jack, C. R., Shiung, M. M., Gunter, J. L., O’Brien, P. C., Weigand, S. D., Knopman, D. S., Boeve, B. F., Ivnik, R. J., Smith, G. E., Cha, R. H., et al. (2004) · Neurology · doi:10.1212/01.wnl.0000110315.26026.ef · Cited by 827 · cited 1×
“Many techniques have been developed to quantify disease progression from serial MRI in neurological disorders (Freeborough and Fox, 1997; Smith et al., 2001; Ashburner et al., 2003; Wang et al., 2002; Jack et al., 2004; Janke et al., 2001; Thompson et al., 2004).”
BackgroundSelf-citationComputer-assisted imaging to assess brain structure in healthy and diseased brains
Ashburner, J., Csernansk, J. G., Davatzikos, C., Fox, N. C., Frisoni, G. B., & Thompson, P. M. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00304-1 · Cited by 371
Self-citation
Cited by
N4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073
The Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2013) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.05.1769 · Cited by 1,010
Self-citationLarge-scale evaluation of ANTs and FreeSurfer cortical thickness measurements
Tustison, N. J., Cook, P. A., Klein, A., Song, G., Das, S. R., Duda, J. T., Kandel, B. M., van Strien, N., Stone, J. R., Gee, J. C., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.044 · Cited by 670
“…between the two subsets.4 We then used the training data to create two models for each pipeline: 1) standard linear regression and 2) random forests (a non-parametric machine learning technique) (Breiman, 2001), for estimating age from both ANTs and FreeSurfer thickness values in the testing data.”
MethodThe Alzheimer's Disease Neuroimaging Initiative: Progress report and future plans
Weiner, M. W., Aisen, P. S., Jack, C. R., Jagust, W. J., Trojanowski, J. Q., Shaw, L., Saykin, A. J., Morris, J. C., Cairns, N., Beckett, L. A., et al. (2010) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2010.03.007 · Cited by 599
Self-citationAn Open Source Multivariate Framework for n-Tissue Segmentation with Evaluation on Public Data
Avants, B. B., Tustison, N. J., Wu, J., Cook, P. A., & Gee, J. C. (2011) · Neuroinformatics · doi:10.1007/s12021-011-9109-y · Cited by 576
The Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.09.172 · Cited by 476
Self-citationValverde, S., Cabezas, M., Roura, E., González-Villà, S., Pareto, D., Vilanova, J. C., Ramió-Torrentà, L., Rovira, À., Oliver, A., & Lladó, X. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.034 · Cited by 392
Update on the Magnetic Resonance Imaging core of the Alzheimer's Disease Neuroimaging Initiative
Jack, C. R., Bernstein, M. A., Borowski, B. J., Gunter, J. L., Fox, N. C., Thompson, P. M., Schuff, N., Krueger, G., Killiany, R. J., DeCarli, C. S., et al. (2010) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2010.03.004 · Cited by 378
Self-citationWeiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Cedarbaum, J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.11.001 · Cited by 348
“Boyes et al [53] tested the ability of nonparametric nonuniform intensity normalization (N3) to eliminate these artifacts on higherfield 3-”
BackgroundSelf-citationVijayakumar, N., Allen, N. B., Youssef, G., Dennison, M., Yücel, M., Simmons, J. G., & Whittle, S. (2016) · Human Brain Mapping · doi:10.1002/hbm.23154 · Cited by 279
Cortical maturation and myelination in healthy toddlers and young children
Deoni, S. C. L., Dean, D. C., Remer, J., Dirks, H., & O’Muircheartaigh, J. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.058 · Cited by 221
Magnetic resonance imaging in Alzheimer’s disease neuroimaging initiative 2
Jack, C. R., Barnes, J., Bernstein, M. A., Borowski, B. J., Brewer, J., Clegg, S., Dale, A. M., Carmichael, O., Ching, C., DeCarli, C., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2015.05.002 · Cited by 220
Self-citationDennison, M., Whittle, S., Yücel, M., Vijayakumar, N., Kline, A., Simmons, J., & Allen, N. B. (2013) · Developmental Science · doi:10.1111/desc.12057 · Cited by 146
Hua, X., Lee, S., Yanovsky, I., Leow, A. D., Chou, Y.-Y., Ho, A. J., Gutman, B., Toga, A. W., Jack, C. R., Bernstein, M. A., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.011 · Cited by 145
“The effects of phantom-based corrections, image inhomogeneity corrections (Boyes et al., 2008), and other image processing steps on longitudinal stability can also be extensively explored, monitored, and optimized, as are effects of the field strength of the scanner (3 versus 1.5 T) (Ho et al., in…”
BackgroundInfluentialSelf-citationSlattery, C. F., Beck, J. A., Harper, L., Adamson, G., Abdi, Z., Uphill, J., Campbell, T., Druyeh, R., Mahoney, C. J., Rohrer, J. D., et al. (2014) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.05.1751 · Cited by 119
Self-citationVijayakumar, N., Whittle, S., Dennison, M., Yücel, M., Simmons, J., & Allen, N. B. (2014) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2013.12.002 · Cited by 71
“All images were also corrected for tissue signal inhomogeneity using FreeSurfer’s N3 correction (optimized for 3 Tesla images), a non-parametric non-uniformity intensity normalization method, which reduces sensitivity to changes in scanner platform and improves accuracy and robustness during cortical segmentation (Boy…”
A review of Methods for Bias Correction in Medical Images
Song, S., Zheng, Y., & He, Y. (2017) · Biomedical Engineering Review · doi:10.18103/bme.v3i1.1550 · Cited by 62
Metadata
- Authors
- Boyes, R. G., Gunter, J. L., Frost, C., Janke, A. L., Yeatman, T., Hill, D. L. G., Bernstein, M. A., Thompson, P. M., Weiner, M. W., Schuff, N., Alexander, G. E., Killiany, R. J., DeCarli, C., Jack, C. R., & Fox, N. C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2008-02
- Volume
- 39
- Issue
- 4
- Pages
- 1752-1762
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2164225814
- Cited by
- 146
- References
- 4
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.