Impact of scanner hardware and imaging protocol on image quality and compartment volume precision in the ADNI cohort
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Morphometry of brain structures based on magnetic resonance imaging (MRI) data has become an important tool in neurobiology. Recent multicenter studies in neurodegenerative diseases raised the issue of the precision of volumetric measures, and their dependence on the scanner properties and imaging protocol. A large dataset consisting of 1073 MRI examinations in 843 subjects, acquired on 90 scanners at 58 sites, is analyzed here. A comprehensive set of image quality and content measures is used to describe the influence of the scanner hardware and imaging protocol on the variability of morphometric measures. Scanners equipped with array coils show a remarkable advantage over conventional coils in terms of image quality measures. The signal- and contrast-to-noise ratio in similar systems is equal or slightly better at 1.5 T than 3.0 T, while the white/grey matter tissue contrast is generally better on high-field systems. Repeated MRI investigations on the same scanner were available in 41 subjects, on different scanners in 172 subjects. The retest reliability of repeated volumetric measures under the same conditions was found as sufficient to track changes in longitudinal examinations in individual subjects. Using different acquisition conditions in the same subject, however, the variance of volumetric measures was up to 10 times greater. Two likely factors explaining this finding are scanner-dependent geometrical inaccuracies and differences in the white/grey matter tissue contrast.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voxel-Based Morphometry—The Methods
Ashburner, J., & Friston, K. J. (2000) · NeuroImage · doi:10.1006/nimg.2000.0582 · Cited by 8,676
Mixed-effects modeling with crossed random effects for subjects and items
Baayen, R. H., Davidson, D. J., & Bates, D. M. (2008) · Journal of Memory and Language · doi:10.1016/j.jml.2007.12.005 · Cited by 8,540
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
The Alzheimer's Disease Neuroimaging Initiative
Mueller, S. G., Weiner, M. W., Thal, L. J., Petersen, R. C., Jack, C., Jagust, W., Trojanowski, J. Q., Toga, A. W., & Beckett, L. (2005) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2005.09.008 · Cited by 1,525
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Brain atrophy rates predict subsequent clinical conversion in normal elderly and amnestic MCI
Jack, C. R., Shiung, M. M., Weigand, S. D., O’Brien, P. C., Gunter, J. L., Boeve, B. F., Knopman, D. S., Smith, G. E., Ivnik, R. J., Tangalos, E. G., et al. (2005) · Neurology · doi:10.1212/01.wnl.0000180958.22678.91 · Cited by 492 · cited 1×
“Magnetic resonance imaging (MRI) and image analysis methods can track brain atrophy at multiple time-points, and have revealed fi ne-scale anatomical changes associated with cognitive decline, e.g., (Fox et al., 2000; Jack et al., 2005).”
Atlas Renormalization for Improved Brain MR Image Segmentation Across Scanner Platforms
Han, X., & Fischl, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.893282 · Cited by 215 · cited 4×
“Itisworthwhileand necessaryto study the advantage of protocol-speci fi c corrections (e.g., a phantom-based geometrical correction, parameter optimization) (Han and Fischl, 2006; Jovicich et al., 2006).”
InfluentialLeow, A. D., Yanovsky, I., Parikshak, N., Hua, X., Lee, S., Toga, A. W., Jack, C. R., Bernstein, M. A., Britson, P. J., Gunter, J. L., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.004 · Cited by 180
Cited by
The Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2013) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2013.05.1769 · Cited by 1,010
The Alzheimer's Disease Neuroimaging Initiative: Progress report and future plans
Weiner, M. W., Aisen, P. S., Jack, C. R., Jagust, W. J., Trojanowski, J. Q., Shaw, L., Saykin, A. J., Morris, J. C., Cairns, N., Beckett, L. A., et al. (2010) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2010.03.007 · Cited by 599
The Alzheimer's Disease Neuroimaging Initiative: A review of papers published since its inception
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., Liu, E., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.09.172 · Cited by 476
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Cedarbaum, J., Green, R. C., Harvey, D., Jack, C. R., Jagust, W., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2014.11.001 · Cited by 348
“Kruggel et al [46] also investigated the effect of scanner strength and the type of coil used on image quality and found that a 3.”
BackgroundInfluentialImpact of the Alzheimer's Disease Neuroimaging Initiative, 2004 to 2014
Weiner, M. W., Veitch, D. P., Aisen, P. S., Beckett, L. A., Cairns, N. J., Cedarbaum, J., Donohue, M. C., Green, R. C., Harvey, D., Jack, C. R., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2015.04.005 · Cited by 239
“The ADNI phantom helped correct scanner scaling errors or miscalibrations [36] and to reduce between scanner imaging artifacts in longitudinal studies [37].”
Boosting power for clinical trials using classifiers based on multiple biomarkers
Kohannim, O., Hua, X., Hibar, D. P., Lee, S., Chou, Y.-Y., Toga, A. W., Jack, C. R., Weiner, M. W., & Thompson, P. M. (2010) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2010.04.022 · Cited by 190
“The few ADNI studies that have assessed the field strength effect (Ho et al., 2009; Kruggel et al., 2010) suggest that 1.”
InfluentialDetect and correct bias in multi-site neuroimaging datasets
Wachinger, C., Rieckmann, A., & Pölsterl, S. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101879 · Cited by 115
Structural brain development: A review of methodological approaches and best practices
(2017) · doi:10.1016/j.dcn.2017.11.008 · Cited by 124
Van Schuerbeek, P., Baeken, C., De Raedt, R., De Mey, J., & Luypaert, R. (2011) · Brain Research · doi:10.1016/j.brainres.2010.11.073 · Cited by 94
Cortical signatures of cognition and their relationship to Alzheimer’s disease
Initiative, F. T. A. D. N., Gross, A. L., Manly, J. J., Pa, J., Johnson, J. K., Park, L. Q., Mitchell, M. B., Melrose, R. J., Inouye, S. K., & McLaren, D. G. (2012) · Brain Imaging and Behavior · doi:10.1007/s11682-012-9180-5 · Cited by 25
Ten years of image analysis and machine learning competitions in dementia
Bron, E. E., Klein, S., Reinke, A., Papma, J. M., Maier-Hein, L., Alexander, D. C., & Oxtoby, N. P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119083 · Cited by 17
Hoogenboom, W. S., Perlis, R. H., Smoller, J. W., Zeng-Treitler, Q., Gainer, V. S., Murphy, S. N., Churchill, S. E., Kohane, I. S., Shenton, M. E., & Iosifescu, D. V. (2013) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2012.07.007 · Cited by 13
“Another study limitation is that MRI data has been previously collected as part of routine clinical treatment using multiple scanner hardware and imaging protocols, which may affect the reliability of measures and reproducibility of results (Kruggel et al., 2010).”
Background
Metadata
- Authors
- Kruggel, F., Turner, J., & Muftuler, L. T.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2010-02
- Volume
- 49
- Issue
- 3
- Pages
- 2123-2133
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2031224239
- Cited by
- 165
- References
- 8
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.