Three dimensional echo-planar imaging at 7 Tesla
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Functional MRI (fMRI) most commonly employs 2D echo-planar imaging (EPI). The advantages for fMRI brought about by the increasingly popular ultra-high field strengths are best exploited in high-resolution acquisitions, but here 2D EPI becomes unpractical for several reasons, including the very long volume acquisitions times. In this study at 7 T, a 3D EPI sequence with full parallel and partial Fourier imaging capability along both phase encoding axes was implemented and used to evaluate the sensitivity of 3D and corresponding 2D EPI acquisitions at four different spatial resolutions ranging from small to typical voxel sizes (1.5–3.0mm isotropic). Whole-brain resting state measurements (N=4) revealed a better, or at least comparable sensitivity of the 3D method for gray and white matter. The larger vulnerability of 3D to physiological effects was outweighed by the much shorter volume TR, which moreover allows whole brain coverage at high resolution within fully acceptable limits for event-related fMRI: TR was only 3.07s for 1.5 mm, 1.88 s for 2.0mm, 1.38 s for 2.5 mm and 1.07s for 3.0 mm isotropic resolution. In order to investigate the ability to detect and spatially resolve BOLD activation in the visual cortex, functional 3D EPI experiments (N=8) were performed at 1mm isotropic resolution with parallel imaging acceleration of 3×3, resulting in a TR of only 3.2s for whole-brain coverage. From our results, and several other practical advantages of 3D over 2D EPI found in the present study, we conclude that 3D EPI provides a useful alternative for whole-brain fMRI at 7 Tesla, not only when high-resolution data are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Temporal Autocorrelation in Univariate Linear Modeling of FMRI Data
Woolrich, M. W., Ripley, B. D., Brady, M., & Smith, S. M. (2001) · NeuroImage · doi:10.1006/nimg.2001.0931 · Cited by 2,852
Triantafyllou, C., Hoge, R. D., Krueger, G., Wiggins, C. J., Potthast, A., Wiggins, G. C., & Wald, L. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.007 · Cited by 648
Self-citationPoser, B. A., Versluis, M. J., Hoogduin, J. M., & Norris, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20900 · Cited by 439
Self-citationElectrodynamics and ultimate SNR in parallel MR imaging
Wiesinger, F., Boesiger, P., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20183 · Cited by 282
Liu, G., Sobering, G., Duyn, J., & Moonen, C. T. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300617 · Cited by 205
Principles of magnetic resonance assessment of brain function
Norris, D. G. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20587 · Cited by 186
Cited by
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
“As such, it was shown that 3D acquisition times could be reduced to levels near or faster than what is obtained with 2D multi-slice imaging, greatly improving the performance of 3D functional images over 2D [15,39].”
BackgroundUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“…2D EPI acquisitions, in recent years multi-shot 3D EPI acquisitions are becoming increasingly popular at 3 T and 7 T to achieve high spatial resolution with larger SNR values than their 2D counterparts (Jorge et al., 2013; Narsude et al., 2016; Poser et al., 2010; van der Zwaag et al., 2012).”
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Huber, L., Handwerker, D. A., Jangraw, D. C., Chen, G., Hall, A., Stüber, C., Gonzalez-Castillo, J., Ivanov, D., Marrett, S., Guidi, M., et al. (2017) · Neuron · doi:10.1016/j.neuron.2017.11.005 · Cited by 341
Self-citationPrediction during natural language comprehension
Willems, R. M., Frank, S. L., Nijhof, A. D., Hagoort, P., & van den Bosch, A. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhv075 · Cited by 288
“T2*-weighted 3D echo planar imaging sequence (Poser et al. 2010), with high temporal resolution (time to repetition: 880 ms, time to echo: 28 ms, flip angle: 14°, voxel size: 3.”
BackgroundMemory hierarchies map onto the hippocampal long axis in humans
Collin, S. H. P., Milivojevic, B., & Doeller, C. F. (2015) · Nature Neuroscience · doi:10.1038/nn.4138 · Cited by 259
Brand, M., Snagowski, J., Laier, C., & Maderwald, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.033 · Cited by 198
Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla
Feinberg, D. A., Beckett, A. J. S., Vu, A. T., Stockmann, J., Huber, L., Ma, S., Ahn, S., Setsompop, K., Cao, X., Park, S., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02068-7 · Cited by 196
“Whole-brain VASO data were acquired using a segmented IR 3D EPI sequence 33,34 using a 4 × 2 shot-selective CAIPI trajectory 84 with a phase encode CAIPI shift of two.”
Self-citationLayer-dependent activity in human prefrontal cortex during working memory
Finn, E. S., Huber, L., Jangraw, D. C., Molfese, P. J., & Bandettini, P. A. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0487-z · Cited by 192
Advances in resting state fMRI acquisitions for functional connectomics
Raimondo, L., Oliveira, Ĺ. A. F., Heij, J., Priovoulos, N., Kundu, P., Leoni, R. F., & van der Zwaag, W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118503 · Cited by 180
Todd, N., Moeller, S., Auerbach, E. J., Yacoub, E., Flandin, G., & Weiskopf, N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.056 · Cited by 173
“…temporal resolution, and ongoing work is investigating the merits of multi-shot 3D gradient echo EPI, multi-slab echo-volumar imaging, and 3D balanced steadystate free precession approaches (Lutti et al., 2013; Poser et al., 2010; Posse et al., 2012; Swisher et al., 2012; Tijssen et al., 2011).”
BackgroundImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“…leads to increased volume acquisition times (TR) necessitating compromises such as large slices, inter-slice gaps or sacrificed temporal resolution (e.g., (Bianciardi et al., 2009a, 2009b, 2009c; Poser and Norris, 2009; van der Zwaag et al., 2009a; van der Zwaag et al., 2009b; Poser et al., 2010)).”
BackgroundThe relationship between oscillatory EEG activity and the laminar-specific BOLD signal
Scheeringa, R., Koopmans, P. J., van Mourik, T., Jensen, O., & Norris, D. G. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522577113 · Cited by 162
Self-citationA hemodynamic model for layered BOLD signals
Heinzle, J., Koopmans, P. J., den Ouden, H. E. M., Raman, S., & Stephan, K. E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.025 · Cited by 144
“Recent advances in high-field functional magnetic resonance imaging (fMRI) have made it feasible to measure blood oxygen level dependent (BOLD) signals from cortical structures with sub-millimeter resolution (Feinberg et al., 2010; Moeller et al., 2010; Poser et al., 2010; Heidemann et al., 2012).”
BackgroundSelf-citationLawrence, S. J., Norris, D. G., & de Lange, F. P. (2019) · eLife · doi:10.7554/elife.44422 · Cited by 95
Metadata
- Authors
- Poser, B. A., Koopmans, P. J., Witzel, T., Wald, L. L., & Barth, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 51
- Issue
- 1
- Pages
- 261-266
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2093198155
- Cited by
- 284
- References
- 22
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.